Flow Factor sells COAX ATEX Valves
|
COAX ATEX Valves |
For tough slurries and other hard to handle fluids, use COAX coaxial Valve with their straight through design for full proof operation.
email requests to: info@flowfactor.com
CO-AX® VALVES INC. – CETLUS ANNOUNCEMENT
co-ax® valves inc. is pleased to announce that its solenoid valves – Series MK 15, FK 15, MK 20, FK 20, MK 25, FK 25, FK 40 and FK 50 – are now cETLus listed. The obtained listing determines that our valves are suitable for installation in hazardous locations.
The ETL Listed Mark indicates that the product has been tested by ITS ETL SEMKO, and found to be in compliance with the following accepted national standards:
ISA 12.12.01 and CSA C22.2 No 213 which is the harmonized CSA Group and UL standard for Nonincendive Electrical Equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified) locations.
General Specifications
Functionexplosion-proof valvesMediacombustible gases according NPT 260, gaseous, liquid, gelatinous, highly viscous, pasty, contaminated, aggressive, liquid fuelsBody Materialsbrass, galvanized steel, nickel plated brass, nickel plated steel, without non-ferrous metals, stainless steel 1.4101
The materials refer to parts in contact with the media.Seal MaterialsNBR, PTFE, FPM, CR, EPDM, special seal materialsOptionsspecial threads, special flanges, function NO, damping, limit switches (NAMUR), manual override, approvals, special voltage, circuit amplifier, mountingRemarkThe valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.
MK 10 DR EX
PortsMK threads NPT 1/4 - NPT 3/4FunctionNCPressure Range0-240 psi
A ⇒ B max. 240 psi
B ⇒ A max. 240 psi
A ⇒ C max. 240 psi
C ⇒ A max. 240 psicv Value3.0 GPMMediagaseous, liquid, contaminatedFlow Directionsee pressure rangeSwitching Cycles200 1/minSwitching Time [ms]opening 80 closing 140Media Temperature [°F]DC: -4 to 104
AC: -4 to 104Ambient Temp. [°F]DC: -4 to 104
AC: -4 to 104Weight [kg]MK 2,2Nominal VoltageUN 24 V DC, UN 230 V 40-60 Hz ACActuationDC direct-current magnet
AC direct-current magnet with integrated rectifierProtectionIP65Energized Duty RatingED 100%Connectionterminal box, 3 m flying leads
MK / FK 15 DR EX
|
ATEX Rated COAX MK/FK Valve for difficult Applications |
PortsMK threads NPT 3/8 - NPT 3/4
FK flanges ANSI 150 / 600FunctionNCPressure Range0-240 / 0-600 psi
A ⇒ B max. 600 psi
B ⇒ A max. 240 psi
A ⇒ C max. 600 psi
C ⇒ A max. 240 psicv Value5.0 GPMMediagaseous, liquid, highly viscous, gelatinous, contaminatedFlow Directionsee pressure rangeSwitching Cycles200 1/minSwitching Time [ms]opening 80 closing 80Media Temperature [°F]DC: -4 to 104
AC: -4 to 104Ambient Temp. [°F]DC: -4 to 104
AC: -4 to 104Weight [kg]MK 4,3 FK 5,9Nominal VoltageUN 24 V DC, UN 230 V 40-60 Hz ACActuationDC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof areaProtectionIP65Energized Duty RatingED 100%Connection
MK / FK 20 DR EX
|
COAX Valve ATEX Rated MK/FK 20DR |
Ports
MK threads NPT 3/4 - NPT 11/4
FK flanges ANSI 150 / 600FunctionNCPressure Range0-240 / 0-600 psi
A ⇒ B max. 600 psi
B ⇒ A max. 240 psi
A ⇒ C max. 600 psi
C ⇒ A max. 240 psicv Value7.7 GPMMediagaseous, liquid, highly viscous, gelatinous, contaminatedFlow Directionsee pressure rangeSwitching Cycles150 1/minSwitching Time [ms]opening 110 closing 110Media Temperature [°F]DC: -4 to 104
AC: -4 to 104Ambient Temp. [°F]DC: -4 to 104
AC: -4 to 104Weight [kg]MK 6,0 FK 8,4Nominal VoltageUN 24 V DC, UN 230 V 40-60 Hz ACActuationDC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof areaProtectionIP65Energized Duty RatingED 100%ConnectionM16x1,5 terminal box
MK / FK 25 DR EX
|
MK25 FK25 COAX ATEX Valves for Difficult Applications |
Ports
MK threads NPT 1 - NPT 11/2FK flanges ANSI 150 / 600FunctionNCPressure Range0-240 / 0-600 psi
A ⇒ B max. 600 psi
B ⇒ A max. 240 psi
A ⇒ C max. 600 psi
C ⇒ A max. 240 psicv Value12.9 GPMMediagaseous, liquid, highly viscous, gelatinous, contaminatedFlow Directionsee pressure rangeSwitching Cycles130 1/minSwitching Time [ms]opening 130 closing 130Media Temperature [°F]DC: -4 to 104
AC: -4 to 104Ambient Temp. [°F]DC: -4 to 104
AC: -4 to 104Weight [kg]MK 9,2 FK 12,0Nominal VoltageUN 24 V DC, UN 230 V 40-60 Hz ACActuationDC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof areaProtectionIP65Energized Duty RatingED 100%ConnectionM16x1,5 terminal box
MK / FK 32 DR EX
|
MK32/FK32 Coax Valves Atex For Difficult Applications |
Ports
MK threads NPT 11/4 - NPT 11/2
FK flanges ANSI 150 / 600FunctionNCPressure Range0-240 / 0-600 psi
A ⇒ B max. 600 psi
B ⇒ A max. 240 psi
A ⇒ C max. 600 psi
C ⇒ A max. 240 psicv Value16.2 GPM (A ⇒ B), 10.3 GPM (A ⇒ C)Mediagaseous, liquid, highly viscous, gelatinous, contaminatedFlow Directionsee pressure rangeSwitching Cycles120 1/minSwitching Time [ms]opening 440 closing 250Media Temperature [°F]DC: -4 to 104
AC: -4 to 104Ambient Temp. [°F]DC: -4 to 104
AC: -4 to 104Weight [kg]MK 18,0 FK 22,0Nominal VoltageUN 24 V DC, UN 230 V 40-60 Hz ACActuationDC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof areaProtectionIP65Energized Duty RatingED 100%ConnectionM16x1,5 terminal box
MK / FK 40 DR EX
|
COAX MK40 FK40 Valve Ex-Proof ATEX Valves for Difficult Applications |
PortsMK threads NPT 11/2 - NPT 2
FK flanges ANSI 150FunctionNCPressure Range0-240 psi
A ⇒ B max. 240 psi
B ⇒ A max. 240 psi
A ⇒ C max. 240 psi
C ⇒ A max. 240 psicv Value21.3 GPM (A ⇒ B), 13.3 GPM (A ⇒ C)Mediagaseous, liquid, highly viscous, gelatinous, contaminatedFlow Directionsee pressure rangeSwitching Cycles90 1/minSwitching Time [ms]opening 520 closing 150Media Temperature [°F]DC: -4 to 104
AC: -4 to 104Ambient Temp. [°F]DC: -4 to 104
AC: -4 to 104Weight [kg]MK 18,5 FK 23,0Nominal VoltageUN 24 V DC, UN 230 V 40-60 Hz ACActuationDC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof areaProtectionIP65Energized Duty RatingED 100%Connection
MK / FK 50 DR EX
|
COAX ATEX MK50 FK50 Valves for Difficult Applaictions |
PortsMK threads NPT 2
FK flanges ANSI 150FunctionNCPressure Range0-240 psi
A ⇒ B max. 240 psi
B ⇒ A max. 150 psi
A ⇒ C max. 240 psi
C ⇒ A max. 240 psicv Value32.6 GPMMediagaseous, liquid, highly viscous, gelatinous, contaminatedFlow Directionsee pressure rangeSwitching Cycles40 1/minSwitching Time [ms]opening 400 closing 400Media Temperature [°F]DC: -4 to 104
AC: -4 to 104Ambient Temp. [°F]DC: -4 to 104
AC: -4 to 104Weight [kg]MK 31,5 FK 38,5Nominal VoltageUN 24 V DC, UN 230 V 40-60 Hz ACActuationDC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof areaProtectionIP65Energized Duty RatingED 100%ConnectionM16x1,5 terminal box
To Specify a valve, please include the following:
Orifice Size
Port Size
Function - NO or NC
Operating Pressure in PSI or BAR.
Flow Rate Needed
Media
Media Temperature
Ambient Temperature
Nominal Voltage
email requests to: info@flowfactor.com
Or use our valve design form HERE!
CO-AX VALVES INC. IS PART OF THE MÜLLER COAX GROUP
Best Mobile Casinos of 2021 - JTM Hub
ReplyDeleteThere 창원 출장샵 are a ton of 속초 출장샵 mobile casinos out 영주 출장샵 there, and they all have 남양주 출장샵 some big names on this list. A few are the ones that are 서귀포 출장마사지