General Specifications
Functionexplosion-proof valvesMediacombustible gases according NPT 260, gaseous, liquid, gelatinous, highly viscous, pasty, contaminated, aggressive, liquid fuelsBody Materialsbrass, galvanized steel, nickel plated brass, nickel plated steel, without non-ferrous metals, stainless steel 1.4101
The materials refer to parts in contact with the media.Seal MaterialsNBR, PTFE, FPM, CR, EPDM, special seal materialsOptionsspecial threads, special flanges, function NO, damping, limit switches (NAMUR), manual override, approvals, special voltage, circuit amplifier, mountingRemarkThe valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.
To Specify a valve, please include the following:
Orifice Size
Port Size
Function - NO or NC
Operating Pressure in PSI or BAR.
Flow Rate Needed
Media
Media Temperature
Ambient Temperature
Nominal Voltage
email requests to: info@flowfactor.com
VALVE TYPES
KBS 15 EX
|
co-ax KBS 15 EX Valve |
PortsKBS threads NPT 3/8FunctionNCPressure Rangepsi | 600 | 1500 | 2250 |
orifice [mm] | 3 | 2 | 1.5 |
cv Valuel/min | 5.2 | 1.3 | 1.1 |
DN [mm] | 3 | 2 | 1.5 |
Mediagaseous, liquidFlow DirectionA ⇒ B as markedSwitching Cycles120 1/minSwitching Time [ms]opening 250 closing 160Media Temperature [°F]DC: -4 to 104
AC: -4 to 104Ambient Temp. [°F]DC: -4 to 104
AC: -4 to 104Weight [kg]4,2Nominal VoltageUN 24 V DC, UN 230 V 40-60 Hz ACActuationDC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof areaProtectionIP65Energized Duty RatingED 100%ConnectionM16x1,5 terminal box
KB 15 EX
|
co-ax KB 15 EX Valve |
PortsKB threads NPT 3/8FunctionNCPressure Rangepsi | 150 | 150 | 240 | 450 | 750 | 1500 |
DN [mm] | 8 | 6 | 5 | 4 | 3 | 2 |
cv Valuel/min | 24.0 | 17.4 | 13.5 | 11.0 | 4.1 | 1.7 |
DN [mm] | 8 | 6 | 5 | 4 | 3 | 2 |
Mediagaseous, liquidFlow DirectionA ⇒ B as markedSwitching Cycles210 1/minSwitching Time [ms]opening 100 closing 175Media Temperature [°F]DC: -4 to 104
AC: -4 to 104Ambient Temp. [°F]DC: -4 to 104
AC: -4 to 104Weight [kg]2,8Nominal VoltageUN 24 V DC, UN 230 V 40-60 Hz ACActuationDC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof areaProtectionIP65Energized Duty RatingED 100%ConnectionM16x1,5 terminal boxMK 10 EX
|
COAX ATEX Coaxial Valve for difficult applications |
PortsMK threads NPT 1/4 - NPT 3/4FunctionNCPressure Range0-240 psicv Value2.9 GPMMediagaseous, liquid, contaminatedFlow DirectionA ⇒ B as markedSwitching Cycles200 1/minSwitching Time [ms]opening 80 closing 140Media Temperature [°F]DC: -4 to 104
AC: -4 to 104Ambient Temp. [°F]DC: -4 to 104
AC: -4 to 104Weight [kg]MK 1,5Nominal VoltageUN 24 V DC, UN 230 V 40-60 Hz ACActuationDC direct-current magnet
AC direct-current magnet with integrated rectifierProtectionIP65Energized Duty RatingED 100%Connectionterminal box, 3 m flying leads
MK / FK 15 EX
|
COAX ATEX MK FK 15 EX Coaxial Valve for difficult applications |
Ports
MK threads NPT 3/8 - NPT 3/4FK flanges ANSI 150 / 600 / 1500FunctionNCPressure Range0-240 / 0-600 / 0-960 / 0-1500 psicv Value5.5 GPMMediagaseous, liquid, highly viscous, gelatinous, contaminatedFlow DirectionA ⇒ B as markedSwitching Cycles200 1/minSwitching Time [ms]opening 80 closing 80Media Temperature [°F]DC: -4 to 104
AC: -4 to 104Ambient Temp. [°F]DC: -4 to 104
AC: -4 to 104Weight [kg]MK 3,8 FK 5,0Nominal VoltageUN 24 V DC, UN 230 V 40-60 Hz ACActuationDC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof areaProtectionIP65Energized Duty RatingED 100%ConnectionM16x1,5 terminal box
MK / FK 20 EX
|
COAX MK/FK 20 Coaxial Valve for difficult applications |
PortsMK threads NPT 3/4 - NPT 11/4
FK flanges ANSI 150 / 600 / 1500FunctionNCPressure Range0-240 / 0-600 / 0-960 / 0-1500 psicv Value8.6 GPMMediagaseous, liquid, highly viscous, gelatinous, contaminatedFlow DirectionA ⇒ B as markedSwitching Cycles150 1/minSwitching Time [ms]opening 110 closing 110Media Temperature [°F]DC: -4 to 104
AC: -4 to 104Ambient Temp. [°F]DC: -4 to 104
AC: -4 to 104Weight [kg]MK 5,5 FK 7,5Nominal VoltageUN 24 V DC, UN 230 V 40-60 Hz ACActuationDC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof areaProtectionIP65Energized Duty RatingED 100%ConnectionM16x1,5 terminal box
MK / FK 25 EX
|
COAX MK/FK 25 ATEX Coaxial Valves for Difficult Applications |
PortsMK threads NPT 1 - NPT 11/2
FK flanges ANSI 150 / 600 / 1500FunctionNCPressure Range0-240 / 0-600 / 0-960 / 0-1500 psicv Value12.9 GPMMediagaseous, liquid, highly viscous, gelatinous, contaminatedFlow DirectionA ⇒ B as markedSwitching Cycles130 1/minSwitching Time [ms]opening 130 closing 130Media Temperature [°F]DC: -4 to 104
AC: -4 to 104Ambient Temp. [°F]DC: -4 to 104
AC: -4 to 104Weight [kg]MK 8,0 FK 10,5Nominal VoltageUN 24 V DC, UN 230 V 40-60 Hz ACActuationDC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof areaProtectionIP65Energized Duty RatingED 100%ConnectionM16x1,5 terminal box
MK / FK 32 EX
|
COAX Coaxial MK/FK 32 ATEX Valve for Difficult Applications |
PortsMK threads NPT 11/4 - NPT 11/2
FK flanges ANSI 150 / 600 / 1500FunctionNCPressure Range0-240 / 0-600 / 0-960 psicv Value16.3 GPMMediagaseous, liquid, highly viscous, gelatinous, contaminatedFlow DirectionA ⇒ B as markedSwitching Cycles120 1/minSwitching Time [ms]opening 440 closing 250Media Temperature [°F]DC: -4 to 104
AC: -4 to 104Ambient Temp. [°F]DC: -4 to 104
AC: -4 to 104Weight [kg]MK 13,5 FK 17,5Nominal VoltageUN 24 V DC, UN 230 V 40-60 Hz ACActuationDC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof areaProtectionIP65Energized Duty RatingED 100%ConnectionM16x1,5 terminal box
MK / FK 40 EX
|
ATEX Approved COAX coaxial Valves MK/FK 40 for difficult applications |
PortsMK threads NPT 11/2 - NPT 2
FK flanges ANSI 150 / 600 / 1500FunctionNCPressure Range0-240 / 0-600 / 0-960 psicv Value21.3 GPMMediagaseous, liquid, highly viscous, gelatinous, contaminatedFlow DirectionA ⇒ B as markedSwitching Cycles90 1/minSwitching Time [ms]opening 520 closing 150Media Temperature [°F]DC: -4 to 104
AC: -4 to 104Ambient Temp. [°F]DC: -4 to 104
AC: -4 to 104Weight [kg]MK 14,0 FK 18,0Nominal VoltageUN 24 V DC, UN 230 V 40-60 Hz ACActuationDC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof areaProtectionIP65Energized Duty RatingED 100%ConnectionM16x1,5 terminal box
MK / FK 50 EX
|
COAX MK/FK 50 Coaxial Valve ATEX for Difficult Applications |
PortsMK threads NPT 2
FK flanges ANSI 150FunctionNCPressure Range0-240 psicv Value32.6 GPMMediagaseous, liquid, highly viscous, gelatinous, contaminatedFlow DirectionA ⇒ B as markedSwitching Cycles40 1/minSwitching Time [ms]opening 400 closing 400Media Temperature [°F]DC: -4 to 104
AC: -4 to 104Ambient Temp. [°F]DC: -4 to 104
AC: -4 to 104Weight [kg]MK 25,5 FK 31,0Nominal VoltageUN 24 V DC, UN 230 V 40-60 Hz ACActuationDC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof areaProtectionIP65Energized Duty RatingED 100%ConnectionM16x1,5 terminal boxTo Specify a valve, please include the following: