Wednesday, June 16, 2021

COAX Explosion Proof Coaxial Valves

 Flow Factor sells COAX ATEX Valves



COAX ATEX Valves






For tough slurries and other hard to handle fluids, use COAX coaxial Valve with their straight through design for full proof operation.

email requests to:  info@flowfactor.com

CO-AX® VALVES INC. – CETLUS ANNOUNCEMENT

co-ax® valves inc. is pleased to announce that its solenoid valves – Series MK 15, FK 15, MK 20, FK 20, MK 25, FK 25, FK 40 and FK 50 – are now cETLus listed. The obtained listing determines that our valves are suitable for installation in hazardous locations.

The ETL Listed Mark indicates that the product has been tested by ITS ETL SEMKO, and found to be in compliance with the following accepted national standards:

ISA 12.12.01 and CSA C22.2 No 213 which is the harmonized CSA Group and UL standard for Nonincendive Electrical Equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 Hazardous (Classified) locations.




General Specifications


Function
explosion-proof valves
Media
combustible gases according NPT 260, gaseous, liquid, gelatinous, highly viscous, pasty, contaminated, aggressive, liquid fuels
Body Materials
brass, galvanized steel, nickel plated brass, nickel plated steel, without non-ferrous metals, stainless steel 1.4101
The materials refer to parts in contact with the media.
Seal Materials
NBR, PTFE, FPM, CR, EPDM, special seal materials
Options
special threads, special flanges, function NO, damping, limit switches (NAMUR), manual override, approvals, special voltage, circuit amplifier, mounting
Remark
The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.

MK 10 DR EX

Ports
MK threads NPT 1/4 - NPT 3/4
Function
NC
Pressure Range
0-240 psi
A ⇒ B max. 240 psi
B ⇒ A max. 240 psi
A ⇒ C max. 240 psi
C ⇒ A max. 240 psi
cv Value
3.0 GPM
Media
gaseous, liquid, contaminated
Flow Direction
see pressure range
Switching Cycles
200 1/min
Switching Time [ms]
opening 80 closing 140
Media Temperature [°F]
DC: -4 to 104
AC: -4 to 104
Ambient Temp. [°F]
DC: -4 to 104
AC: -4 to 104
Weight [kg]
MK 2,2
Nominal Voltage
UN 24 V DC, UN 230 V 40-60 Hz AC
Actuation
DC direct-current magnet
AC direct-current magnet with integrated rectifier
Protection
IP65
Energized Duty Rating
ED 100%
Connection
terminal box, 3 m flying leads

MK / FK 15 DR EX

ATEX Rated COAX MK/FK Valve
for difficult Applications


















Ports
MK threads NPT 3/8 - NPT 3/4
FK flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
A ⇒ B max. 600 psi
B ⇒ A max. 240 psi
A ⇒ C max. 600 psi
C ⇒ A max. 240 psi
cv Value
5.0 GPM
Media
gaseous, liquid, highly viscous, gelatinous, contaminated
Flow Direction
see pressure range
Switching Cycles
200 1/min
Switching Time [ms]
opening 80 closing 80
Media Temperature [°F]
DC: -4 to 104
AC: -4 to 104
Ambient Temp. [°F]
DC: -4 to 104
AC: -4 to 104
Weight [kg]
MK 4,3 FK 5,9
Nominal Voltage
UN 24 V DC, UN 230 V 40-60 Hz AC
Actuation
DC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof area
Protection
IP65
Energized Duty Rating
ED 100%
Connection



MK / FK 20 DR EX

COAX Valve ATEX Rated MK/FK 20DR



Ports










MK threads NPT 3/4 - NPT 11/4
FK flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
A ⇒ B max. 600 psi
B ⇒ A max. 240 psi
A ⇒ C max. 600 psi
C ⇒ A max. 240 psi
cv Value
7.7 GPM
Media
gaseous, liquid, highly viscous, gelatinous, contaminated
Flow Direction
see pressure range
Switching Cycles
150 1/min
Switching Time [ms]
opening 110 closing 110
Media Temperature [°F]
DC: -4 to 104
AC: -4 to 104
Ambient Temp. [°F]
DC: -4 to 104
AC: -4 to 104
Weight [kg]
MK 6,0 FK 8,4
Nominal Voltage
UN 24 V DC, UN 230 V 40-60 Hz AC
Actuation
DC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof area
Protection
IP65
Energized Duty Rating
ED 100%
Connection
M16x1,5 terminal box


MK / FK 25 DR EX

MK25 FK25 COAX ATEX Valves
for Difficult Applications


Ports










MK threads NPT 1 - NPT 11/2
FK flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
A ⇒ B max. 600 psi
B ⇒ A max. 240 psi
A ⇒ C max. 600 psi
C ⇒ A max. 240 psi
cv Value
12.9 GPM
Media
gaseous, liquid, highly viscous, gelatinous, contaminated
Flow Direction
see pressure range
Switching Cycles
130 1/min
Switching Time [ms]
opening 130 closing 130
Media Temperature [°F]
DC: -4 to 104
AC: -4 to 104
Ambient Temp. [°F]
DC: -4 to 104
AC: -4 to 104
Weight [kg]
MK 9,2 FK 12,0
Nominal Voltage
UN 24 V DC, UN 230 V 40-60 Hz AC
Actuation
DC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof area
Protection
IP65
Energized Duty Rating
ED 100%
Connection
M16x1,5 terminal box

MK / FK 32 DR EX

MK32/FK32 Coax Valves Atex
For Difficult Applications


Ports










MK threads NPT 11/4 - NPT 11/2
FK flanges ANSI 150 / 600
Function
NC
Pressure Range
0-240 / 0-600 psi
A ⇒ B max. 600 psi
B ⇒ A max. 240 psi
A ⇒ C max. 600 psi
C ⇒ A max. 240 psi
cv Value
16.2 GPM (A ⇒ B), 10.3 GPM (A ⇒ C)
Media
gaseous, liquid, highly viscous, gelatinous, contaminated
Flow Direction
see pressure range
Switching Cycles
120 1/min
Switching Time [ms]
opening 440 closing 250
Media Temperature [°F]
DC: -4 to 104
AC: -4 to 104
Ambient Temp. [°F]
DC: -4 to 104
AC: -4 to 104
Weight [kg]
MK 18,0 FK 22,0
Nominal Voltage
UN 24 V DC, UN 230 V 40-60 Hz AC
Actuation
DC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof area
Protection
IP65
Energized Duty Rating
ED 100%
Connection
M16x1,5 terminal box

MK / FK 40 DR EX

COAX MK40 FK40 Valve Ex-Proof ATEX Valves
for Difficult Applications
















Ports
MK threads NPT 11/2 - NPT 2
FK flanges ANSI 150
Function
NC
Pressure Range
0-240 psi
A ⇒ B max. 240 psi
B ⇒ A max. 240 psi
A ⇒ C max. 240 psi
C ⇒ A max. 240 psi
cv Value
21.3 GPM (A ⇒ B), 13.3 GPM (A ⇒ C)
Media
gaseous, liquid, highly viscous, gelatinous, contaminated
Flow Direction
see pressure range
Switching Cycles
90 1/min
Switching Time [ms]
opening 520 closing 150
Media Temperature [°F]
DC: -4 to 104
AC: -4 to 104
Ambient Temp. [°F]
DC: -4 to 104
AC: -4 to 104
Weight [kg]
MK 18,5 FK 23,0
Nominal Voltage
UN 24 V DC, UN 230 V 40-60 Hz AC
Actuation
DC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof area
Protection
IP65
Energized Duty Rating
ED 100%
Connection



MK / FK 50 DR EX

COAX ATEX MK50 FK50 Valves
for Difficult Applaictions

















Ports
MK threads NPT 2
FK flanges ANSI 150
Function
NC
Pressure Range
0-240 psi
A ⇒ B max. 240 psi
B ⇒ A max. 150 psi
A ⇒ C max. 240 psi
C ⇒ A max. 240 psi
cv Value
32.6 GPM
Media
gaseous, liquid, highly viscous, gelatinous, contaminated
Flow Direction
see pressure range
Switching Cycles
40 1/min
Switching Time [ms]
opening 400 closing 400
Media Temperature [°F]
DC: -4 to 104
AC: -4 to 104
Ambient Temp. [°F]
DC: -4 to 104
AC: -4 to 104
Weight [kg]
MK 31,5 FK 38,5
Nominal Voltage
UN 24 V DC, UN 230 V 40-60 Hz AC
Actuation
DC direct-current magnet, AC direct-current magnet with, separate rectifier outside , of the explosion-proof area
Protection
IP65
Energized Duty Rating
ED 100%
Connection
M16x1,5 terminal box


To Specify a valve, please include the following:

Orifice Size
Port Size
Function - NO or NC
Operating Pressure in PSI or BAR.
Flow Rate Needed
Media
Media Temperature
Ambient Temperature
Nominal Voltage


email requests to:  info@flowfactor.com

Or use our valve design form HERE!



Flow Factor
216-765-4231
www.flowfactor.com

CO-AX VALVES INC. IS PART OF THE MÜLLER COAX GROUP