Barksdale BiT Intelligent ATEX Pressure Transmitter from
Flow Factor
To get a Quote, Please use our Barksdale Parts form
HERE!
Barksdale Series H455X, 455X and 452X
High accuracy pressure transmitter with HART® communicaton protocol with 24 standard ranges from vacuum to 30,000 psi
Barksdale Intelligent Transmitters (BiT), Series 450X is a high pressure, explosion-proof compact transmitter with HART® communication protocol option. HART® enabled sensors can communicate over the legacy two-wire 4-20 mA analog current loops offering smart features like transmitter diagnostics, calibration, and field re-ranging up to 10 times less than calibrated full scale output (10:1 turndown ratio). Three models are available: Series H455X, 4-20 mA output with HART® Comm. Protocol; Series 455X, 4-20 mA output; Series 452X, 1-5 VDC output. These models can be configured with 24-standard pressure ranges from vacuum to 30,000 psi and multiple process connections from 1/4” NPT to 7/16” SAE and HF4 Autoclave high-pressure connections. Series 450X offers hazardous area explosion protection to meet North American, European and international standards with ATEX, IECEx, cULus approvals.
Applications
- Production Control Systems
- Chemical Injection Systems
- Oil & gas pipelines
- Petrochemical plants
- Production Control Systems
- Chemical Injection Systems
- Oil & gas pipelines
- Petrochemical plants
Features
Lightweight, compact and all-welded rugged stainless steel construction
High performance sensors for high accuracy
Optional HART® communication protocol with diagnostics & field
calibration, reducing maintenance time and cost; and 10:1 turndown ratio
for re-ranging, maintaining high accuracy and allowing one part number for
multiple pressure ranges
High accuracy: ±0.1% and ±0.25% FSO, (L,H,R)
cULus, ATEX, IECEx and Single Seal certifications
Explosion proof enclosure with IP66 & IP67 and NEMA 4X, 7 & 9 ratings
CE, CRN, and NACE compliant and superior EMI/EMC protection
Factory sealed, environment friendly, halogen free wires and cable
RoHS & REACH Compliant
cULus approved as telemetering
equipment for use in hazardous locations
(UL File E146589, WYMV, WYMV7)
factory sealed, Type 4X, as follows:
Class I, Div. 1, Groups A, B, C & D
Class II, Div. 1, Groups E, F & G
CE 0081
CE II 2 G D
Ex db IIC T5 Gb
Ex tb IIIC T81°C Db, IP66 & IP67
-40 °C ≤ Tamb ≤ +80 °C
DEMKO 18 ATEX 2084
IECEx UL 18.0090
HART® Protocol: HART® 7.6
The below Barksdale Transmitters provide a 4-20mA current output with HART Protocol
H455X-23 0-29.9 of Hg (Vacuum)
H455X-01 0-15 psi
H455X-21 0-30 psi
H455X-03 0-50 psi
H455X-22 0-60 psi
H455X-04 0-100 psi
H455X-05 0-150 psi
H455X-06 0-200 psi
H455X-07 0-300 psi
H455X-08 0-500 psi
H455X-10 0-1000 psi
H455X-11 0-1500 psi
H455X-12 0-2000 psi
H455X-13 0-3000 psi
H455X-14 0-4000 psi
H455X-15 0-5000 psi
H455X-16 0-6000 psi
H455X-17 0-7500 psi
H455X-18 0-10,000 psi
H455X-29-P15 0-15,000 psi
H455X-30-P15 0-20,000 psi
H455X-31-P15 0-22,000 psi
H455X-32-P15 0-25,000 psi
H455X-33-P15 0-30,000 psi
The below Barksdale Transmitters provide a 4-20mA current output with HART Protocol
H455X-23B 0 to -1 Bar (Vacuum)
H455X-01B 0-1 Bar
H455X-21B 0-2 Bar
H455X-03B 0-3 Bar
H455X-22B 0-4 Bar
H455X-04B 0-7 Bar
H455X-05B 0-10 Bar
H455X-06B 0-15 Bar
H455X-07B 0-20 Bar
H455X-08B 0-40 Bar
H455X-10B 0-70 Bar
H455X-11B 0-100 Bar
H455X-12B 0-150 Bar
H455X-13B 0-200 Bar
H455X-14B 0-300 Bar
H455X-15B 0-350 Bar
H455X-16B 0-400 Bar
H455X-17B 0-500 Bar
H455X-18B 0-700 psi
H455X-29B-P15 0-1000 Bar
H455X-30B-P15 0-1400 Bar
H455X-31B-P15 0-1500 Bar
H455X-32B-P15 0-1700 Bar
H455X-33B-P15 0-2000 Bar
The below Barksdale Transmitters provide a 4-20mA current output (No HART)
455X-23 0-29.9 of Hg (Vacuum)
455X-01 0-15 psi
455X-21 0-30 psi
455X-03 0-50 psi
455X-22 0-60 psi
455X-04 0-100 psi
455X-05 0-150 psi
455X-06 0-200 psi
455X-07 0-300 psi
455X-08 0-500 psi
455X-10 0-1000 psi
455X-11 0-1500 psi
455X-12 0-2000 psi
455X-13 0-3000 psi
455X-14 0-4000 psi
455X-15 0-5000 psi
455X-16 0-6000 psi
455X-17 0-7500 psi
455X-18 0-10,000 psi
455X-29-P15 0-15,000 psi
455X-30-P15 0-20,000 psi
455X-31-P15 0-22,000 psi
455X-32-P15 0-25,000 psi
455X-33-P15 0-30,000 psi
The below Barksdale Transmitters provide a 4-20mA current output (No HART)
455X-23B 0 to -1 Bar (Vacuum)
455X-01B 0-1 Bar
455X-21B 0-2 Bar
455X-03B 0-3 Bar
455X-22B 0-4 Bar
455X-04B 0-7 Bar
455X-05B 0-10 Bar
455X-06B 0-15 Bar
455X-07B 0-20 Bar
455X-08B 0-40 Bar
455X-10B 0-70 Bar
455X-11B 0-100 Bar
455X-12B 0-150 Bar
455X-13B 0-200 Bar
455X-14B 0-300 Bar
455X-15B 0-350 Bar
455X-16B 0-400 Bar
455X-17B 0-500 Bar
455X-18B 0-700 psi
455X-29B-P15 0-1000 Bar
455X-30B-P15 0-1400 Bar
455X-31B-P15 0-1500 Bar
455X-32B-P15 0-1700 Bar
455X-33B-P15 0-2000 Bar
The below Barksdale Transmitters provide a 0-10 VDC current output (No HART)
452X-23 0-29.9 of Hg (Vacuum)
452X-01 0-15 psi
452X-21 0-30 psi
452X-03 0-50 psi
452X-22 0-60 psi
452X-04 0-100 psi
452X-05 0-150 psi
452X-06 0-200 psi
455X-07 0-300 psi
452X-08 0-500 psi
452X-10 0-1000 psi
452X-11 0-1500 psi
452X-12 0-2000 psi
452X-13 0-3000 psi
452X-14 0-4000 psi
452X-15 0-5000 psi
452X-16 0-6000 psi
452X-17 0-7500 psi
452X-18 0-10,000 psi
452X-29-P15 0-15,000 psi
452X-30-P15 0-20,000 psi
452X-31-P15 0-22,000 psi
452X-32-P15 0-25,000 psi
452X-33-P15 0-30,000 psi
To get a Quote, Please use our Barksdale Parts form
HERE!
Flow Factor
216-765-4231
www.flowfactor.com
452X Barksdale 455X 452X Barksdale 455X Barksdale 452X Barksdale 455X 452X Barksdale H455X