Sunday, December 2, 2012

King Gage Liquid Level Transmitters

Flow Factor sells KING GAGE Level Systems

Common applications are:


  • Beverages
  • Fats & Oils
  • Dairy Products
  • Fruit & Vegetable Juices
  • Sauces & Condiments
  • Confectionery




KING-GAGE® ES2 transmitters provide liquid level measurement for inventory monitoring. Add to their rugged reliability the major benefits of simplified service and maintenance. Performance characteristics of these transmitters include excellent stability and repeatability (better than 0.02% FS). Transmitter span accommodates a 3:1 turndown ratio* to match the application pressure range (i.e. tank depth) and the 4-20 mAdc output is compatible with PLCs or other control architecture using analog I/O.
KING-GAGE ES2 transmitters are applicable to most tanks or process vessels whose contents remain at normal atmospheric pressure. They measure hydrostatic head pressure created by liquid depth in the tank and are unaffected by foaming or internal obstructions such as agitators. Unlike load cells, pressure based measurement has lower installation cost and is far simpler to maintain thus ensuring more reliable readings. 
Transmitters used in sanitary processing must often endure cycles of rapid temperature fluctuation. Washdown environments produce significant condensation on metallic surfaces that coupled with aggressive cleansing agents demand robust protection for these instruments. The ES2 transmitter's enhanced design uses encapsulation for full isolation of the internal electronics. This extends to the IP68 grade M12 signal connector that ensure integrity and long term reliability. You can be assured of a transmitter truly built for the demands and expectations of today's processing environment.
Sanitary Configurations
These sensors are especially suited to a wide range of sanitary applications on storage or continuous processing vessels. The 316 stainless diaphragm is appropriate for flush mount, clean-in-place installation employing an FDA-approved silicone rubber O-ring seal to achieve the crevice-free, positive compression seal between diaphragm and tank liner. Sanitary tank mountings include flush weld mountings with product contact surfaces of 316L stainless. (Quick disconnect sanitary adapters are also available for sensor mounting.)

*3:1 turndown ratio is applicable to 0-10 and 0-30 nominal range, refer to specifications for detailed span adjustment available on specific range models.
Mounting Options
Flush-mounting configurations are intended to meet the 3-A Sanitary Standards for clean-in-place applications. The ES2 transmitter fits directly into KING-GAGE tank shells or with an adapter on other manufacturers' mounting shells.

Installation Options
The KING-GAGE ES2 transmitter offers a choice of configurations to match your application needs. The integral stainless steel housing shown here includes a watertight connector for signal cable installation. Mounting lengths offered are intended to mate with tank fittings on non-insulated (singlewall) or insulated wall tanks. Adapters provide additional mounting options when retrofitting systems from other manufacturers.







LevelBAR Tank Level Indicator

• Visual Display of Tank Levels
• Custom Scale for Weight or Volume
• Direct Replacement for Manometer Gauges
• 4-20 mA output signal available to PLC 

The LevelBAR multi-segment LED column display includes an individualized scale calibrated to the actual tank capacity. Marked in any specified unit(s) of measurement, it permits direct reading of total liquid weight or volume. This unique analog column indicator works as a local or auxiliary remote display in new or retrofit applications.

Pneumatic input models include an integrated differential pressure (D/P) element. This allows LevelBAR to be used with bubblers or other air operated systems as a direct replacement for mercury tank gauges or other fluid-filled manometers. It even provides 4-20 mA output compatible with other receivers or to use for process control functions.



LP2 Multiple Tank Digital Indicator


•  8 Tank Multiple Channel Capacity
•  Operator Interface Display & Keypad
•  RS-485 Multidrop Communications

LP2 Multiple Tank Indicators expresses tank level directly in engineering units. Referencing a capacity profile to correlate transmitter output to actual tank geometry, the indicator formats the resulting value directly as the total weight or volume of liquid in the tank. LP2 Multiple Tank Indicator provides an operator interface keypad for access to function selection and density adjustments. There are no user conversion factors involved or scaling points to enter. All application details are factory programmed into an innovative nonvolatile modular memory called the Datapack iButton.

LP2 multiple tank indicators accept up to eight input channels that receive proportional 4-20 mA signals from liquid level transmitters. The actual sensor used to detect hydrostatic pressure created by liquid depth can be either electronic or pneumatic (using an electronic pressure transmitter to convert the sensor's pneumatic signal into 4-20 mA output).

LP2 multiple tank indicators can be used to eliminate analog I/O at your PLC or PC-based control system. As data acquisition hubs, each LP2 tank level indicator provides multiple point serial communications. An expandable network of up to 32 discrete indicators can be installed on a single two wire network (RS-485) for total of 256 possible input channels. Dual serial ports support multiple network configurations including query-response communications with a computer (or PLC), remote satellite displays, or interface to a KING-GAGE® LP3 system.



Contact Flow Factor HERE.
216-765-4231





No comments:

Post a Comment