Picking a Solenoid Valve using TOMS PAVE from Flow Factor
An easy way to help pick out a valve is an acronym TOMSPAVE.
Use the Flow Factor Valve Parts form for a quote. Click HERE!
T = Type of valve
2-way, 3-way, 4-way
O = Operation
Normally Closed, Normally Open, Diverting, Universal
M = Media
Water, Oil, Gas, Steam, Other
S = Size
1/8, 1/4, 1/2, 3/4, 1, 1.5, 2, 3 Inch NPT
P = Pressure
PSI required in your application
A = Ambient Situation
Wet, Hazardous, Temperature, Indoor, Outdoor
V= Voltage
24/60, 120/60, 240/60, 480/60, 12vdc, 24vdc, 120vdc, Other
E = Extras
Mounting Bracket, Timer, Spade Tabs, DIN coil, Screw Terminals
Use the Flow Factor Valve Design Form to help pick your valve.
Use the Flow Factor Valve Parts Form for a quote.
Flow Factor
216-765-4231
www.flowfactor.com
Sunday, August 11, 2019
Wednesday, July 31, 2019
Barksdale CNG Transducer for Fleets
Flow Factor can provide the Barksdale CNG Transducer
To get a quote please use our Barksdale Parts Form HERE!
Fueling your transportation fleet with natural gas isn’t just a savvy eco-friendly business move; natural gas is a safe, effective and low cost alternative fuel source. The shift from diesel to clean fuels has created a growing demand for fuel system components that can meet the strict requirements of NGV3.1 standards.
To get a quote please use our Barksdale Parts Form HERE!
Fueling your transportation fleet with natural gas isn’t just a savvy eco-friendly business move; natural gas is a safe, effective and low cost alternative fuel source. The shift from diesel to clean fuels has created a growing demand for fuel system components that can meet the strict requirements of NGV3.1 standards.
COMPACT & ROBUST DESIGN – Ideal CNG solution
At Barksdale, we work closely with our customers to develop solutions that offer a competitive advantage in the marketplace. The Series 650 CNG Pressure Transducer was designed specifically for accurately monitoring and controlling CNG fuels to ensure your system operates at maximum efficiency. Ideal for long-term use even in harsh environments of extreme temperature, humidity and vibration, Barksdale pressure transducers is the preferred choice for high pressure CNG transducers that are certified to industry standards and organization approvals. Designed for compact and mobile applications, the CNG high pressure transducer series easily installs into systems where spacing is limited. From monitoring external air tank supply’s to braking system, our high performance, high pressure CNG transducer are used for pressure applications where reliability and quality are critical to keeping your fleets on the road. Our staff of dedicated engineers shares one purpose: to create and design innovative, application specific solutions to meet your exact requirements.
KEY FEATURES:
- Conforms to ANSI/CSA NGV 4.2-2014
- Working pressure up to 5,000 psi
- Wide operating temperature -40°C to +85°C
- One-piece design with 316 stainless steel wetted material
Accuracy - +/- .05% full scale at 77ºF
Operating Temp Range is -40º to 257ºF
Wetted Parts : Ceramic, Corrosion Resistant 316 Stainless Steel, Flourocarbon Elastomer (FKM)
Enclosure: 316 Stainless Steel
Outputs: 1-5 vdc, 0.5 - 4.5 VDC, 4-20mA, 0-10 volts VDC
Response time is 2 ms
Approval - CSA
Enclosure rating : IP67, NEMA 4
Models:
653 = 1-5 VDC output
654 = 0.5 - 4.5 VDC output
655 = 4-20 mA output
657 = 0-10 VDC output
Pressure Ranges:
Suffix / PSI
-15 = 0-15 psi
-30 = 0-30 psi
-100 = 0-100 psi
-150 = 0-150 psi
-300 = 0-300 psi
-1000 = 0-1000 psi
-2400 = 0-2400 psi
-3000 = 0-3000 psi
-3600 = 0-3600 psi
-5000 = 0-5000 psi
Flow Factor
216-765-4231
Tuesday, June 4, 2019
Aircraft Fire Trainer with co-ax valves
Flow Factor and co-ax® valves application
Get a quote for co-ax®
HERE!
Aircraft Fire Trainer
Aircraft Fire Trainer are designed to recreate a series of different emergency scenarios, including interior and exterior incident fires and large-scale fuel spill fires on airplanes, all managed by an adjacent control tower and PC control station. Inside, a series of fires can be accessed by a series of doors on multiple levels, helping to develop realistic rescue scenarios.
Aircraft Fire Trainers are fully programmable, and automatically respond to the application of extinguishing media, for a realistic fire response.
Fire simulations utilize clean burning propane. Alternately, "dual-fueled" fire simulations are available that burn either kerosene for maximum realism or propane for environmental compliance.
Summary
co-ax® valves are used to release propane or liquid fuel to the plane mock-up shown in the picture. The fuel is ignited and the fire is extinguished by fire fighting trainees. They use water to extinguish the flames. Water also keeps the mock-up from distorting. The co-ax® valves are submerged under the gravel and water in the bottom of the pool.
Why are co-ax® valves the preferred choice?
- Positive shut-off.
- Fast open/closing speed < 100 milliseconds required.
- Compact size.
- Valves (externally controlled) can be buried in a pit.
Typical co-ax® valves being used in this application
- VMK 20 NC
- VFK 25 NC
- MK 10 NC 1E
Flow Factor
216-765-4231
www.flowfactor.com
CO-AX VALVES INC. IS PART OF THE MÜLLER CO-AX GROUP
Sunday, June 2, 2019
co-ax® valves for polyol applications
co-ax® valves from Flow Factor
Get a quote for co-ax HERE!
Flow Factor
216-765-4231
www.flowfactor.com
CO-AX VALVES INC. IS PART OF THE MÜLLER CO-AX GROUP
Get a quote for co-ax HERE!
co-ax® valves for polyol applications
co-ax® valves being used in this application
- PCS-1 10, PCS-1 15, PCS-2 10, PCS-2 15, PCS-3 15, PCB-1 10, PCD-1 10 - cartridge valves, externally controlled KB 15 direct acting valves
- VMK-H 15, VMK-H 15 DR, VMK-H 20, VMK-H 25, VSV-M 50
co-ax® valves are used to inject polyol, which then blends together with isocyanates to create a chemical compound called polyurethanes.
The mixture of the chemicals form molds for many different applications, which are used to create mattresses, foam insulation for refrigerators and freezers, home and automotive seats, elastomeric shoe soles, fibers (e.g. Spandex), and adhesives.
Isocyanates, when exposed to air, tend to form crystals that generate premature wear in valves, especially those containing abrasive fillers and they are equally destructive to the seals and seat.
Multiple co-ax® valves have been designed and sold for polyol applications. The fast actuation speeds of the co-ax® valve combined with high cycle life and virtually no maintenance are key advantages for this application.
Why are co-ax® valves the preferred choice?
- Fast actuation
- Engineered for long life (high cycle life)
- Pressure balanced design
Get a quote for co-ax HERE!
Flow Factor
216-765-4231
www.flowfactor.com
CO-AX VALVES INC. IS PART OF THE MÜLLER CO-AX GROUP
Labels:
Air Acuated,
ASCO,
Burkert,
co-ax,
coaxail valves,
CX-Tec,
Jefferson Valves,
Parker,
polyyol,
Solenoid Valves
Saturday, May 18, 2019
co-ax valves for blow molding applications
Flow Factor and co-ax valves can solve many industrial applications with the co-ax coaxial valve line. Robust and works.
Request a Quote HERE for co-ax valves.
Flow Factor
216-765-4231
www.flowfactor.com
co-ax® valves offer accuracy, repeatability and fast actuation for blow molding applications
![]() |
| co-ax valves for blow molding and industrial processes |
VMK 10 DR NC
Blow molding is a manufacturing process where hollow plastic items are formed - in this case, plastic bottles. This specific blow molding machine uses an externally controlled (air operated) co-ax valve to operate. The air (500 psi) flows from port B to port A to form the bottle; once the plastic bottle is formed, the valve closes and the air is exhausted from port A to port C through a muffler.
Blow molding of plastic bottles requires air pressure control that is exact, repeatable and fast acting. Downtime can be devastating and have a costly impact to all manufacturers. Most conventional valves struggle to offer accuracy, repeatability and fast actuation for the toughest applications. As a result, premature failures and operational problems can occur. These can easily be prevented by using a co-ax valve.
The externally controlled (air operated) co-ax® valve is pressure balanced with operating conditions that can be customized with suitable seat and seal materials for virtually any applications. They are designed to be low maintenance and durable for a wide variety of applications, making them the best choice for systems that require high performance and reliable valves with predictable opening and closing speeds.
Why are co-ax® valves the preferred choice?
- Reduce downtime and maintenance cost
- Engineered for long life (high cycle life)
- Pressure balanced design
- Adjustable opening and closing speeds
Request a Quote HERE for co-ax valves.
Flow Factor
216-765-4231
www.flowfactor.com
Tuesday, May 14, 2019
Submersible co-ax® valves
Flow Factor Sells
Submersible co-ax® valves
Valve failure is a persistent threat to valve manufacturers and their customers when it comes to submerging a valve in water, particularly in seawater. The consequences are much worse compared to standard installations that can be more easily reached. Given the challenges that sub-marine environments present such as difficult access, valve corrosion and frequent maintenance, the submersible co-ax® valves are engineered for high cycle and fast actuation plus long, reliable and leak-free performance in aggressive environments.
Submersible co-ax® valves meet performance, safety and reliability expectations in deep water and harsh environments and are designed for depths of 50 feet and deeper upon request. co-ax® valves inc. has been the leader in valve technology for almost 60 years and continues to develop ways to innovative and handle the most specific and difficult applications. Companies throughout the industry have used co-ax® valves in harsh marine environments and continue to trust our dependability in the most demanding valve applications.
![]() |
| co-ax submersible valves |
Use our co-ax valve parts form for a quotation HERE.
Flow Factor
216-765-4231
Labels:
120 volts,
2-way,
220 volts,
240/60,
3-way,
Air Acuated,
co-ax,
COAX,
submersible,
Valves
Monday, April 29, 2019
Watlow Heaters Heating Requirements
General Method for Determining Watlow Heater Requirements
![]() |
| Electric Heaters, Heating Elements and Controls |
Contact Flow Factor HERE!
Most electrical heating problems can be readily solved by determining the heat required to do the job. To do this, the heat requirement must be converted to electrical Power and the most practical heater can then be selected for the job. Whether the problem is heating solids, liquids or gases, the method, or approach, to determining the Power requirement is the same.
All heating problems involve the following steps to their solution:
Step 1: Define the Heating Problem
- Gather application information
- Sketch problem for visual reference
Step 2: Calculate Power Requirements
- System start-up power requirement
- System maintenance power requirements
- Operating heat losses
Step 3: Review System Application Factors
- Operating temperature
- Operating efficiency
- Safe/permissible watt densities
- Mechanical considerations
- Operating environment factors
- Heater life requirements
- Electrical lead considerations
Step 4: Select Heater
- Type
- Size
- Quantity
Step 5: Select Control System
- Type of temperature sensor and location
- Type of temperature controller
- Type of power controller
Defining the Problem
Your heating problem must be clearly stated, paying careful attention to defining operating parameters. Take these into consideration:
- Minimum start and finish temperatures expected
- Maximum flow rate of material(s) being heated
- Required time for start-up heating and process cycle times
- Weights and dimensions of both heated material(s) and containing vessel(s)
- Effects of insulation and its thermal properties
- Electrical requirements — voltage
- Temperature sensing methods and location(s)
- Temperature controller type
- Power controller type
- Electrical limitations
- And since the thermal system you're creating may not take into account all the possible or unforeseen heating requirements, don't forget a safety factor. A safety factor increases heater capacity beyond calculated requirements.
Calculations for Required Heat Energy
When performing your own calculations, refer to Equations for values of materials covered by these equations.
The total heat energy (kWh or Btu) required to satisfy the system needs will be either of the two values shown below depending on which calculated result is larger.
- Heat required for start-up
- Heat required to maintain the desired temperature
The power required (kW) will be the heat energy value (kWh) divided by the required start-up or working cycle time.
The kW rating of the heater will be the greater of these values plus a safety factor.
The calculation of start-up and operating requirements consist of several distinct parts that are best handled separately. However, a short method can also be used for a quick estimate of heat energy required.
Safety Factor Calculation
You should always include a safety factor of varying size to allow for unknown or unexpected conditions. The size of the safety factor is dependent on the accuracy of the wattage calculation. Heaters should always be sized for a higher value than the calculated figure. A factor of 10% is adequate for small systems that are closely calculated; 20% additional wattage is more common. Safety factors of 20% and 35% are not uncommon, and should be considered for large systems, such as those containing doors that open or are large radiant heat applications. You'll also want to predict how long your system will operate without failure, so examine the amount of heater life you'll be needing. And because electricity costs money, take efficiency factors into account so your system will cost as little as possible to operate.
With these considerations in mind, carefully review them all to be sure you do, in fact, have definitive information to decide on a particular solution to your heating problem. Some of this supporting information may not be readily available or apparent to you. You may find it necessary to consult the reference tables and charts in this reference data section, or reference a book that deals with the particular parameter you need to define. At the minimum, the thermal properties of both the material(s) being processed/heated and their containing vessel(s) will be required.
Figuring a safety factor requires some intuition on your part. The list of possible influences can be great. From changing ambient operating temperatures, caused by seasonal changes, to a change in material or material temperature being processed, you must carefully examine all the influences.
Generally speaking, the smaller the system with fewer variables and outside influences---the smaller the safety factor. Conversely, the larger the system and the greater the variables and outside influences — the greater the safety factor.
Here are some general guidelines:
- 10% safety factor for small systems with closely calculated power requirements
- 20% safety factor is average20% to 35% for large systems
The safety factor should be higher for systems that have production operations that contain equipment cycles subjecting them to excessive heat dissipations, e.g.: opening doors on furnaces, introducing new batches of material that can be of varying temperatures, large radiant applications and the like.
Flow Factor
216-765-4231
Subscribe to:
Posts (Atom)