Thursday, January 28, 2021

Littelfuse COM 4-20MA Series

 Littelfuse COM 4-20MA Series Analog Comm Link for Model 777-AccuPower

from Flow Factor

The Com 4-20mA Output Module is intended for use with ONLY the Model 777-AccuPower output power monitor. The module will send a 4-20mA signal proportional to the output power. It can also be used to send the input power by setting the efficiency setting on the 777-AccuPower monitor to one. This module allows communication to a PLC with an analog input and no Modbus input.

Click HERE for a quotation

FeaturesJJ 

Powered by the 777-AccuPowerJJ 

Scalable 4-20mA output proportional to Hp or kWJJ 

Signal can be used for displays, controllers, or PLCs

Littelfuse COM 4-20mA Module  


 

 

 

 

 

 

 

 

 

 

 

Specifications  

Output Characteristics 

Current 4-20mA 

General Characteristics

Temperature Range:  -20° to 50°C (-4° to 122°F)

Terminal: (depluggable terminal block) 

Torque:  3 in.-lbs. (max.) 

Wire:   AWG 12-20 AWG 

Class of Protection:   IP20

Relative Humidity:  10-95%, non-condensing per IEC 68-2-3 

Standards Passed

Electrostatic Discharge:   IEC 61000-4-2, Level 3, 6kV contact,8kV air

Radio Frequency Immunity, Radiated:   150 MHz, 10V/m 

Fast Transient Burst:   IEC 61000-4-4, Level 3, 4kV input power 

Hi-Potential Test:   Meets UL508 (2 x rated V + 1000V for 1 min) 

Surge

 Input Power:   IEC 61000-4-5, Level 1

 Inputs/Data Lines:   IEC 61000-4-5, Level 2

Click HERE for a quotation

Flow Factor
216-765-4231
www.flowfactor.com
 
Littelfuse Com 4-20MA...Littelfuse Com 4-20MA

Littelfuse 777 Accupower Power Monitor

Littelfuse 3-Phase Current & Voltage Monitor 777-Accupower

Request a Quote HERE!

The Littelfuse 777-AccuPower is a fully-programmable 3-phase motor and pump protection relay. It allows motor hp rating, full load amps, efficiency and power factor to be entered and will accurately calculate motor output power. This is most useful with mag-drive pumps or process applications where the process power is desired over the utility power. Voltage, current and power measurements can be displayed as well as fault information and setpoints. The built-in display simplifies troubleshooting and allows the user to easily and precisely configure setpoints. The Littelfuse 777-AccuPower can be used with the optional COM 4-20 output module to give an analog signal proportional to output shaft power, the RS485MS-2W (for limited Modbus capabilities, and for use with the RM1000/RM2000) remote displays listed in the 777 accessories section.

Features & Benefits:

Motor output power measurement 
Allows use of process power over utility power 
 
3 programmable restart delay timers 
Program separate restart delay time for rapid cycle protection, motor cool down, and dry-well recovery 
 
Built-in Display 
Visual indication for programming, viewing real-time voltage or current, and last fault code 
 
Remote display compatibility 
Increases safety through remote display of run-hour meter, last four fault codes, without the need to open the cabinet. Aids with arc flash safety regulations
 
Network communications capability
Limited Modbus capabilities using RS485MS-2W communication module

 

Littelfuse 777-Accupower 3-Phase motor and pump monitor

 

 

 

 

 

 

 

 

 

Specifications:

Input Characteristics 

Line Voltage 200- 4 80VAC

Frequency50/60Hz 

Motor Full Load Amp Range 2-800A (external CTs required over 90A) 

Functional Characteristics 

TC- Overcurrent Trip Class 5, 10, 15, 20, 30(J prefix enables jam protection feature)

 Output Characteristics 

Output Contact Rating (SPDT - Form C) 

Pilot duty 4 80VA @ 24 0VAC

General Purpose10A @ 240VAC

General Characteristics 

Ambient Temperature Range 

Operating-40° to 70°C (-40° to 158°F)Storage -40° to 80°C (-40° to 176°F) 

Accuracy  --  Measured Horsepower/ Kilowatt 

Typical    ± 3 %* * 

Voltage    ±1% 

Current   ±3%

(<100 amps direct)

GF Current   ±15% Timing   5% ±1 second 

Repeatability 

Voltage  ±0.5% of nominal voltage 

Current  ±1% (<100 amps direct) 

Maximum Input Power   10 W 

Pollution Degree    3 

Class of Protection   IP20, NEMA 1 (finger safe)

Relative Humidity    10-95%, non-condensing per IEC 68-2-3 

Terminal Torque    7 in.-lbs

Standards Passed
 
Electrostatic Discharge:  (ESD):   IEC 61000-4-2, Level 3, 6kV contact, 8kV air 
Radio Frequency Immunity (RFI), Conducted:    IEC 61000-4-6, Level 3 10V/m 
Radio Frequency Immunity (RFI), Radiated:    IEC 61000-4-3, Level 310V/m 
Fast Transient Burst:   IEC 61000-4-4, Level 3, 3.5 kV input power 
Short Circuit Rating:     100k A 
 
Surge
 
IEC:   61000-4-5 Level 3, 2kV line-to-line; Level 4, 4kV line-to-ground 
ANSI/IEEE:   C62.41 Surge and Ring Wave Compliance to a level of 6kV line-to-line
Hi-Potential Test:   Meets UL508 (2 x rated V + 1000V for 1 min.) 
Vibration:   IEC 68-2-6, 10-55Hz, 1mm peak-to-peak, 2 hrs, 3 axis 
Shock:   IEC 68-2-27, 30g, 3 axis, 11ms duration, half-sine pulse 
 
Safety Marks 
 
UL:     UL508, UL1053
CE:     IEC 60947-1, IEC 60947-5-1 
CSA:    C22.2
Max. Conductor Size through 777:   0.65” with insulation 
Dimensions :   H 77.47 mm (3.05”); W 97.79 mm (3.85”); D 128.27 mm (5.05”)  
Weight:    1.3 lbs. (20.8 oz., 589.67 g) 
Mounting Method:   Surface mount (4 - #8 screws) or DIN rail mount 
 
**On a well balanced system within recommended current range.
 
 
Littelfuse Model Number
777-AccuPower
 
Accessories:

Littelfuse RS485MS-2W Communication Module
(for limited Modbus capabilities)Required to enable the Modbus communications function on Model 77X-type products.
  
Littelfuse COM 4-20 Output Communication Module
This module allows communication to a PLC with an analog input and no Modbus input.
 
Littelfuse RM1000 Remote Monitor
The RM1000/777 motor management system combines unsurpassed electronic motor protection and critical, user-friendly, motor monitoring for up to 16 devices.
 
Littelfuse RM2000 Remote Monitor
The RM2000/777 motor management system combines unsurpassed electronic motor protection and critical, user-friendly, motor monitoring with event storage and real-time clock for date and time stamp.
 
Request a Quote HERE!
 
Flow Factor
216-765-4231
 
Littelfuse 777-Accupower...Littelfuse 777-Accupower

Wednesday, January 27, 2021

Littelfuse ACBC-120 Alarm Controller for Pumping

Littelfuse ACBC-120 Alarm Controller for Pumping

For a Quote, Please click HERE!

The Littelfuse ACBC-120 is a dual purpose alarm controller/battery charging unit. When there is a loss of 120VAC power, the ACBC-120’s primary function as an alarm controller activates. When this power loss occurs, input power is switched to a 12VDC, lead-acid, rechargeable backup battery and a 12VDC alarm consisting of a strobe light and/or a horn is activated. The horn follows a 2 second on/2 second off pattern with a “horn silence” option to turn the sound off. An LED indicator on the unit also signals that the device has entered the alarm mode.

When 120VAC input is present the alarm circuit can be tested and the Littelfuse unit’s secondary function as a 12VDC backup battery charger is activated. In fast charge mode, the unit has the capability to source up to 100mA of charging current. However, the device normally charges at a current of 14mA in maintenance mode. The alarm circuit can be tested by pressing the “test” button located on the front of the unit or by activating an external switch via the “alarm contact” pin.

The device has the ability to signal low battery voltage if the voltage drops below 10.5VDC. The device can also detect if no battery is present or if the battery is connected backwards. In either of these cases, the Littelfuse ACBC-120 will signal a battery error and will not attempt to charge. The Littelfuse ACBC-120 requires a Rectangular 12 pin socket. for surface mounting.  Littelfuse part number is SD12-PC.

 

Features & Benefits

Controls 12VDC alarm circuit >> Activates strobe and/or horn when power loss occurs 

Selectable fast charge mode >> Unit sources higher charging current up to 100mA (normal mode is 14mA) 

Trip delay timer >> Prevents nuisance tripping

Battery fault detection and reverse polarity protection >> Signals if battery voltage drops below 10.5VDC and can detect if no battery is present or if the battery is connected backwards 

LED Indication >> Visual indication of unit status or trip 

Test button >> Preventative maintenance check of the alarm circuit by pressing the test button on the unit or externally through alarm contact connection


 

 

 

 

 

 

 

 

 

Specifications 

Input Characteristics 

Supply Voltage AC Input Voltage  120 V +/-10%

Frequency  50/60Hz 

AC Input Current 0.018A (max.) 0.003 (typical) 

AC Input Power 2.4W (max.) fast charge current 0.4W (typical) maint. charge current

Functional Characteristics

Battery Charging Characteristics 

Acceptable Battery Type 12V lead-acid rechargeable 

Fast Charge Current 100mA +/-10% 

Maintenance Charge Current14mA +/-50%

Low Battery Alert Level10.5V

Output Characteristics 

Strobe Light Alarm Output 12VDC@1A (max.) 

Horn Alarm Output 12VDC@1A (max.) 

General Characteristics 

Temperature Range-40° to 60°C (-40° to 140°F)

Standards Passed

Electrostatic Discharge (ESD) IEC 61000-4-2, Level 3, 6kV contact, 8kV air 

Radio Frequency, Radiated 15 0MHz, 10V/m 

Fast Transient Burst IEC 61000-4-4, Level 4, 4kV input lines; 4kV signal lines 

Safety Marks

UL:  (SD12-PC socket required) UL508 (File #E68520) 

Dimensions:   H 44.45 mm (1.75”); W 60.325 mm (2.375”); D 104.775 mm (4.125”) (with socket) 

Weight:  0.7 lb. (11.2 oz., 317.51 g) 

Mounting Method:  Surface mount with #8 or #10 screws(plug into SD12-PC socket) 

Socket Available :  Model SD12-PC (UL Rating 600V)The 600V socket can be surface mounted

Ordering Part Numbers

ACBC-120          120 volts
ACBC-120-SD    120 volts with SD12-PC socket included

For a Quote, Please click HERE!

FLOW FACTOR
216-765-4231
www.flowfactor.com 

Littelfuse ACBC-120...Littelfuse ACBC-120...Littelfuse ACBC-120