Showing posts with label GL Series. Show all posts
Showing posts with label GL Series. Show all posts

Friday, January 25, 2019

Emerson GH series Gas/Steam Jet Pumps

Gas Motive High Head (GH Series) Emerson Jet Pumps from Flow Factor

Buy Penberthy Emerson GH Series Eductors HERE!


Features of Emerson Penberthy Jet Pumps (Eductors)
• Simple design with no moving parts to wear out. • No lubrication required.
• Virtually maintenance-free.
• Easy to install without special structures or 
foundations.
• Self-priming.
• Cast, fabricated or non-metallic 
constructions.
• Variety of materials to suit specific characteristics of the process liquids.
• Critical flow paths machined smoothly with
  no abrupt turns or steps, producing the most efficient flow during the motive function.

General Application 
Suitable for a broad range of applications including: handling condensate, pumping wells, circulating solutions, emptying cesspools, pumping brine solutions, extracting solvents, draining cellars, pumping out barges, acidifying, causticizing oils, producing emulsions,elevation water.

Technical Data
Materials: Bronze, iron, carbon steel, 316 SS, PVC, CPVC, PP, PVDF
Sizes: 1⁄2” to 12”
Pressure range: 
15 to 200 psig (1 to 13.8 barg)
Temperature(max): 200°F(93°C) 

Emerson Penberthy GH Series Gas Motive Jet Pump


Size
(Inches)
Emerson HASTELLOY C GH
(High Head) Series Eductors / Jet Pumps
1/2AGH-4AHC
1/2BGH-4BHC
 1/2GH-04HC
 3/4GH-06HC
1    GH-08HC
1 1/4GH-10HC
1 1/2GH-12HC
2    GH-16HC
2 1/2GH-20HC
3    GH-24HC
4    GH-32HC

Size
(Inches)
Emerson Bronze GL
(High Head) Series Eductors / Jet Pumps
1/2AGH-4ABZ
1/2BGH-4BBZ
 1/2GH-04BZ
 3/4GH-06BZ
1    GH-08BZ
1 1/4GH-10BZ
1 1/2GH-12BZ
2    GH-16BZ
2 1/2GH-20BZ
3    GH-24BZ
4    GH-32BZ
Size
(Inches)
Emerson Penberthy Cast Iron GL
(High Head) Series Eductors / Jet Pumps
1/2AGH-4AIR
1/2BGH-4BIR
 1/2GH-04IR
 3/4GH-06IR
1    GH-08IR
1 1/4GH-10IR
1 1/2GH-12IR
2    GH-16IR
2 1/2GH-20IR
3    GH-24IR
4    GH-32IR
Size
(Inches)
Emerson Penberthy Carbon Steel GL
(High Head) Series Eductors / Jet Pumps
1/2AGH-4ACS
1/2BGH-4BCS
 1/2GH-04CS
 3/4GH-06CS
1    GH-08CS
1 1/4GH-10CS
1 1/2GH-12CS
2    GH-16CS
2 1/2GH-20CS
3    GH-24CS
4    GH-32CS
Size
(Inches)
Emerson Stainless Steel GL
(High Head) Series Eductors / Jet Pumps
1/2AGH-4ASS
1/2BGH-4BSS
 1/2GH-04SS
 3/4GH-06SS
1    GH-08SS
1 1/4GH-10SS
1 1/2GH-12SS
2    GH-16SS
2 1/2GH-20SS
3    GH-24SS
4    GH-32SS

Size
(Inches)
Emerson MONEL GH
(High Head) Series Eductors / Jet Pumps
1/2AGH-4AMO
1/2BGH-4BMO
 1/2GH-04MO
 3/4GH-06MO
1    GH-08MO
1 1/4GH-10MO
1 1/2GH-12MO
2    GH-16MO
2 1/2GH-20MO
3    GH-24MO
4    GH-32MO


GAS MOTIVE (AIR/STEAM) Jet Pumps for Pumping or mixing Liquids or gases up to 50 psi discharge head pressure

Operation for Penberthy Emerson Gas Jet Pumps
All Emerson jet pumps operate on the principle of a fluid entraining a second fluid. Although design and construction may vary, this applies to all jet pumps.
All Emerson jet pumps have three common features: inlet, suction and discharge. They function as follows:
Inlet - The operating medium (liquid or steam) under pressure enters the inlet and travels through the nozzle into the suction chamber. The nozzle converts the pressure of the operating medium into a high velocity stream, which passes from the discharge side of the inlet nozzle.
Suction - Pumping action begins when vapor, gases or liquid in the suction chamber are entrained by the high velocity stream emerging from the inlet nozzle, lowering the pressure in the suction chamber. The resulting action causes the liquid, gas or vapor in the suction chamber to flow toward the discharge.
Discharge - The entrained material from the suction system mixes with the operating medium and acquires part of its energy in the parallel section. In the diffuser section, part of the velocity of the mixture is converted to a pressure greater than the suction pressure, but lower than the operating medium pressure. 

Buy Penberthy Emerson GH Series Eductors HERE!

ALL Emerson Penberthy Jets can be found HERE!

Flow Factor
www.flowfactor.com

GH High Head Series Jet Pumps Eductors from Emerson Penberthy 

Wednesday, January 23, 2019

Emerson GL (Gas Motive) Jet Pumps

Gas Motive Low Head (GL Series) Emerson Jet Pumps from Flow Factor

Buy Penberthy Emerson GL Series Eductors HERE!


Features of Emerson Penberthy Jet Pumps (Eductors)
• Simple design with no moving parts to wear out. • No lubrication required.
• Virtually maintenance-free.
• Easy to install without special structures or 
foundations.
• Self-priming.
• Cast, fabricated or non-metallic 
constructions.
• Variety of materials to suit specific characteristics of the process liquids.
• Critical flow paths machined smoothly with
  no abrupt turns or steps, producing the most efficient flow during the motive function.


General Application 
Suitable for a broad range of applications including: handling condensate, pumping wells, circulating solutions, emptying cesspools, pumping brine solutions, extracting solvents, draining cellars, pumping out barges, acidifying, causticizing oils, producing emulsions,elevation water.


Technical Data
Materials: Bronze, iron, carbon steel, 316 SS, PVC, CPVC, PP, PVDF
Sizes: 1⁄2” to 12”
Pressure range: 
15 to 200 psig (1 to 13.8 barg)
Temperature(max): 200°F(93°C) 


Emerson Penberthy GL Series Jet Pump


Size
(Inches)
Emerson HASTELLOY C GL
(Low Head) Series Eductors / Jet Pumps
1/2AGL-4AHC
1/2BGL-4BHC
 1/2GL-04HC
 3/4GL-06HC
1    GL-08HC
1 1/4GL-10HC
1 1/2GL-12HC
2    GL-16HC
2 1/2GL-20HC
3    GL-24HC
4    GL-32HC



Size
(Inches)
Emerson Bronze GL
(Low Head) Series Eductors / Jet Pumps
1/2AGL-4ABZ
1/2BGL-4BBZ
 1/2GL-04BZ
 3/4GL-06BZ
1    GL-08BZ
1 1/4GL-10BZ
1 1/2GL-12BZ
2    GL-16BZ
2 1/2GL-20BZ
3    GL-24BZ
4    GL-32BZ
Size
(Inches)
Emerson Penberthy Cast Iron GL
(Low Head) Series Eductors / Jet Pumps
1/2AGL-4AIR
1/2BGL-4BIR
 1/2GL-04IR
 3/4GL-06IR
1    GL-08IR
1 1/4GL-10IR
1 1/2GL-12IR
2    GL-16IR
2 1/2GL-20IR
3    GL-24IR
4    GL-32IR
Size
(Inches)
Emerson Penberthy Carbon Steel GL
(Low Head) Series Eductors / Jet Pumps
1/2AGL-4ACS
1/2BGL-4BCS
 1/2GL-04CS
 3/4GL-06CS
1    GL-08CS
1 1/4GL-10CS
1 1/2GL-12CS
2    GL-16CS
2 1/2GL-20CS
3    GL-24CS
4    GL-32CS
Size
(Inches)
Emerson Stainless Steel GL
(Low Head) Series Eductors / Jet Pumps
1/2AGL-4ASS
1/2BGL-4BSS
 1/2GL-04SS
 3/4GL-06SS
1    GL-08SS
1 1/4GL-10SS
1 1/2GL-12SS
2    GL-16SS
2 1/2GL-20SS
3    GL-24SS
4    GL-32SS



GAS MOTIVE (AIR/STEAM) Jet Pumps for Pumping or mixing Liquids or gases up to 50 psi discharge head pressure


Operation for Penberthy Emerson Gas Jet Pumps
All Emerson jet pumps operate on the principle of a fluid entraining a second fluid. Although design and construction may vary, this applies to all jet pumps.
All Emerson jet pumps have three common features: inlet, suction and discharge. They function as follows:
Inlet - The operating medium (liquid or steam) under pressure enters the inlet and travels through the nozzle into the suction chamber. The nozzle converts the pressure of the operating medium into a high velocity stream, which passes from the discharge side of the inlet nozzle.
Suction - Pumping action begins when vapor, gases or liquid in the suction chamber are entrained by the high velocity stream emerging from the inlet nozzle, lowering the pressure in the suction chamber. The resulting action causes the liquid, gas or vapor in the suction chamber to flow toward the discharge.
Discharge - The entrained material from the suction system mixes with the operating medium and acquires part of its energy in the parallel section. In the diffuser section, part of the velocity of the mixture is converted to a pressure greater than the suction pressure, but lower than the operating medium pressure. 

Buy Penberthy Emerson GL Series Eductors HERE!

ALL Emerson Penberthy Jets can be found HERE!

Flow Factor
www.flowfactor.com

Low Head Series GL Emerson Penberthy Jet Pumps Eductors

Friday, June 20, 2014

Bosch / Ariston S series Mini-Tanks

Ariston Mini-Tanks updated to S series - Flow Factor

The new Ariston GL6S Plus electric mini-tank water heaters have just arrived. This water heater is the direct replacement for the recently obsoleted Ariston GL6+ (GL6PLUS).

The main difference between the older GL6+ and the new GL6+S is that the GL6+ came with a power cord that plugged directly into a 120V wall socket while the new GL6+S does not come with a power cord. The GL6+S must be hardwired at the time of installation.

Globaltowne does carry a 6' cord for the Ariston GL6+S

Here are the features of the new GL6+S: 
  • 6-year warranty on tank
  • Glass-lined tank for longer life
  • Mounts on wall or floor
  • Temperature/pressure relief valve included
  • Must be hard-wired to 120V
  • Dimensions: 17.5" x 17.5" x 14 1/2"
  • Recovery at 90 Deg F Rise: 7 GPH
  • 12.5 AMPS and 1500W Heating Capacity
  • Temperature Range: 65 Deg F to 145 Deg F
  • Meets ASHRAE 90.1 Standard
  • Relief Valve = Installed
  • Power cord not included
The new Ariston GL6+S model has many new improvements since it has been upgraded. The mini tank has a new temperature adjustment knob on the front of the unit to raise and lower the temperature from 65 Deg F to 145 Deg F. On the older model you would have to remove the blue oval cover to access the temperature knob.

The Ariston GL6+S model has a new improved thermostat that features a new sensing probe that is attached to the thermostat and inserts into the cavity of the new element so the heater can adjust temperatures quicker and maintain a more consistent heat.

Designed by the world's leading point-of-use water heater manufacturer, the New Ariston GLS series combines Italian design and state of the art features including glass-lined tanks, a 6-year warranty and highest recovery time. 

Installing an Ariston electric mini-tank water heater under the sink puts hot water right where you need it - at the point of use. Lightweight and compact and also the Ariston mini tank heaters are great for those long hot water runs from your tank heater or tankless heater and will shorten the wait time for hot water.

The New Ariston GL2.5S mini-tank electric water heater stores 2.5 gallons of hot water. 

The New Ariston GL4S mini-tank electric water heater stores 4 gallons of hot water. 


Please note: The New Ariston GL2.5S is not the direct replacement for the Ariston GL2.5 as the Ariston Gl2.5S is 10 3/4" in depth and the older Ariston GL2.5 was 10 1/4" deep.  The new Ariston GL4S is not the direct replacement for the Ariston GL4 as the GL4S is 13 1/2" in depth and the older Gl4 was 12 1/4" deep.  The replacement parts for the new Ariston GL2.5S and the GL4S will not work for the older GL2.5 and GL4 mini tank heaters.

  • 6-year warranty on tank 
  • Glass-lined tank for longer life  
  • Mounts on wall or floor 
  • Temperature/pressure relief valve included  
  • Plugs into standard 120 volt outlet
  • Dimensions: GL2.5S-13 3/4" x 13 3/4" x 10 3/4", GL4S-13 3/4" x 13 3/4" x 13 1/2"
  • Recovery at 90 Deg F Rise: 7 GPH 
  • 12.5 AMPS and 1500W Heating Capacity 
  • Temperature Range: 65 Deg F to 145 Deg F  
  • Meets ASHRAE 90.1 Standard
  • Relief Valve = Installed
The new Ariston GL2.5S & GL4S models have many new improvements since they have been upgraded.  The mini tanks have a new temperature adjustment knob on the front of the unit to raise and lower the temperature from 65 Deg F to 145 Deg F.  On the older models you would have to remove the blue oval cover to access the temperature control knob.


The Ariston GL2.5S & GL4S models have a new improved thermostat that features a new sensing probe that is attached to the thermostat and inserts into the cavity of the new element so the heater can adjust temperatures quicker and maintain a more consistent heat.



866-360-9830

Sunday, March 30, 2014

Penberthy GH/GL Eductors for Gases

Penberthy/Pentair GL/GH Eductors (jet pumps) for pumping/heating with gas from Flow Factor

Pumping gases using a liquid or gas (steam or air) motive is an effective means of exhausting, evacuating and priming and can be used in a wide variety of operations and industries. These Pentair Penberthy Jet Pumps offer many advantages over other methods of moving gases; they have no moving parts and provide a very simple cost effective method of handling a wide variety of gases and processes. These units are used for all aspects of water treatment, refrigeration, petroleum, petro chemical, brewing, distilling and general process industries.



Features & Benefits:
  • Simple two-piece construction
  • No moving parts to wear out
  • No lubrication
  • Wide variety of special material to suit the most diverse applications
  • Virtually maintenance free
  • Cost effective and inexpensive
  • No power or special installation requirements  



Sizes: 1/2” to 12”
Threaded (Standard) or flanged connections

Operating Pressure Range 20 to 200 psig

Application Range, inches HG. ABS. 0.5 to 30

Materials:
Bronze, Ductile Iron, Carbon Steel, Stainless Steel, PVC, PP, PVDF
Wide variety of special materials also available  

Penberthy jet pumps can also use steam or a gas (air) as the operating media for exhausting, evacuating or priming operations. Primary uses of these types of pumps are for exhausting or evacuating gases. Exhausting means removing gases from an area at a continuous rate while maintaining pressure at a constant level. Evacuation means drawing gases from a defined volume by pumping the vessel down from an initial pressure to a final lower pressure. These steam/gas motive jet pumps meet the industry's most stringent requirements, while providing a simple, low-cost method of transporting gases, operating flawlessly even in the harshest work environments.
Penberthy Models GL and GH operate at pressures from 20 to 120 psig (140 to 830 kPag), the overall capacity being slightly higher when using air as the operating media. U and L Models are single-stage ejectors while the 2NC is a two-stage, non-condensing ejector using steam as the operating media. All these units provide maintenance-free pumping capabilities.
Some uses for steam/gas motive jet pumps include: creating vacuums, exhausting vapors from process systems, evacuating tanks & vessels, priming, fume removal, fluid concentration, humidifying and drying. Industries that could benefit from the use of the jet pumps might include: chemical processing, textile manufacturing, food processing, petroleum production & refining, sterilization and HVAC.

Typical applications involve either exhausting or evacuating. Similar information is needed in order to determine the specific jet pump for your application. Using the information required (listed below), fill out an application form and submit to Penberthy sales representative or the factory to determine the correct pump for your needs.
If Exhausting (Continuous Suction Flow)

Motive:
  • Gas/Steam
  • Pressure (Available)
  • Flow Rate (Available volume-scfm)
  • Temperature
  • Molecular Weight (Gas only)
Suction:
  • Pressure (Inches Hg Abs-kg/sq cm Abs)
  • Flow Rate-scfm
  • Temperature
  • Molecular Weight
Discharge:
  • Pressure (That unit must overcome)

If Evacuating (Sealed Vessel-Pump Down)
  • Volume of Space to Evacuate
  • Required Evacuation Time (Minutes)
MOTIVE:
This function is the power phase of the pumping operation. At this stage, the velocity of the motive media increases as it passes through a nozzle. This phase of the pumping operation takes advantage of the kinetic properties of the motive media, whether it is liquid, steam or gas. Because of this, design differences may exist within the motive connection of the jet pump. For instance, jet pumps with liquid motives use a converging nozzle, since liquids usually cannot be compressed. On the other hand, jet pumps with gas or steam motives use converging/diverging nozzles to achieve trans-sonic flow velocity. The critical flow paths of all Penberthy jet pumps are smoothly machined with no abrupt turns or steps in order to produce the most efficient flow during the motive function. Without this direct flow design and smooth interior surface, the jet pump would not operate at peak efficiency.
SUCTION:
This connection of the jet pump is where the pumping action takes place. The high velocity stream of the motive causes a drop in pressure in the suction chamber. This allows pressure in the suction vessel to push a liquid, steam or gas into the suction chamber of the jet pump. This, in turn, is entrained by the high-velocity motive stream emerging from the inlet nozzle
DISCHARGE:
As the motive flow combines with the suction medium, some kinetic energy of the MOTIVE is transferred to the SUCTION, mixing and discharging at a reduced pressure. The amount of pressure that can be recovered depends on the ratio of the MOTIVE flow to SUCTION flow, plus the amount of SUCTION pressure built up in the suction vessel. Kinetic energy is converted back to pressure as the mixed media passes through the diverging taper and is discharged out the pump.


GL series jets have a motive pressure range of 60-120 psig and suction range of 6-30 inches.
GH series jets have a motive pressure range of 20-80 psig and a suction range of 6.5-30 inches.
Cast eductors can be made from 1/2 inch size to 4 inch size.
Fabricated eductors are 4 inches and up.
Non-Metallic are 1/2 to 3 inch size, these are PVC, Poly Pro, and Kynar.
The common metals are Cast Iron, Low Lead Bronze, Carbon Steel and 316L Stainless Steel.

www.flowfactor.com
866-360-9830