Stiebel Eltron Tempra Tankless Water Heaters

Tankless Technology by the Electric Tankless Leader, Stiebel-Eltron and Flow Factor

The Tempra® series has been redesigned completely inside and out - upgraded heavy-duty electronics, a simple single flow sensor design, a hinged cover for easy access, and Tempra Advanced Flow Control for the Tempra® Plus.

The Tempra® continually heats water instantaneously as you require it - and only when you require it. The Tempra® unit completely replaces a conventional tank heater with no disruption to your comfort and hot water needs.

he Tempra® Plus is the most technologically advanced tankless water heater available on the market today.

Tempra Advanced Flow Control is exclusive to the Tempra® Plus and ensures a constant temperature output no matter how great the hot water demand is.

Tempra Advanced Flow Control technology works by automatically adjusting the flow of water to eliminate unpleasant temperature fluctuation.

What that means to you is a consistently satisfying experience every time, all the time!



Electric tank type water heaters are subject to stand-by losses which amount to 15 - 20% of the kWH used. In addition, water in a tank has to be heated hotter than necessary to account for these stand-by losses.

Changing to a tankless system like the Tempra® eliminates these problems and results in typical savings of at least 15 - 20% on the hot water portion of your electric bill.

Set the knob on the front cover and enjoy water temperatures between 86°F (30°C) and 140°F (60°C). Change the desired temperature at anytime. Advanced microprocessor technology ensures that the water temperature never deviates from the set point.

The Tempra® has several advantages over a gas-type tankless water heater. Compared to many similar gas tankless models the Tempra® is less expensive to purchase. Installation is also much simpler and cheaper since it is not necessary to vent a Tempra® to the outside.

The venting that a gas unit requires causes anywhere from a 10 - 20% efficiency reduction from heat escaping out the exhaust pipe. Furthermore, for every cubic foot of gas burned, roughly two cubic feet of air have to be mixed in to create ideal combustion. In a cold climate, this hurts efficiency further.

When a gas unit fires it draws in air around it, heats the water, and then expels warm exhaust outside. Since no house is airtight, this suction action causes a drafting condition where cold air from the outside seeps back in through door cracks and other parts of the house that may not be airtight.

By nature of the design, the Tempra® is nearly 100% efficient; converting 100% of the electrical energy it consumes into heat. All that heat is then transferred to the water - none is lost to the outdoors.

The Tempra® is a tankless water heater system, and is thereby not subject to seismic code. There is no need for preventative construction, as required when using a tank type water heater.

The Tempra® has several temperature and flow sensors which feed their readings into the unit’s proprietary microprocessor control. Heating elements are engaged in stages, achieving the temperature you desire. The Tempra® continually monitors the water temperature it produces.








866-360-9838
info@flowfactor.com

Friday, June 20, 2014

Bosch / Ariston S series Mini-Tanks

Ariston Mini-Tanks updated to S series - Flow Factor

The new Ariston GL6S Plus electric mini-tank water heaters have just arrived. This water heater is the direct replacement for the recently obsoleted Ariston GL6+ (GL6PLUS).

The main difference between the older GL6+ and the new GL6+S is that the GL6+ came with a power cord that plugged directly into a 120V wall socket while the new GL6+S does not come with a power cord. The GL6+S must be hardwired at the time of installation.

Globaltowne does carry a 6' cord for the Ariston GL6+S

Here are the features of the new GL6+S: 
  • 6-year warranty on tank
  • Glass-lined tank for longer life
  • Mounts on wall or floor
  • Temperature/pressure relief valve included
  • Must be hard-wired to 120V
  • Dimensions: 17.5" x 17.5" x 14 1/2"
  • Recovery at 90 Deg F Rise: 7 GPH
  • 12.5 AMPS and 1500W Heating Capacity
  • Temperature Range: 65 Deg F to 145 Deg F
  • Meets ASHRAE 90.1 Standard
  • Relief Valve = Installed
  • Power cord not included
The new Ariston GL6+S model has many new improvements since it has been upgraded. The mini tank has a new temperature adjustment knob on the front of the unit to raise and lower the temperature from 65 Deg F to 145 Deg F. On the older model you would have to remove the blue oval cover to access the temperature knob.

The Ariston GL6+S model has a new improved thermostat that features a new sensing probe that is attached to the thermostat and inserts into the cavity of the new element so the heater can adjust temperatures quicker and maintain a more consistent heat.

Designed by the world's leading point-of-use water heater manufacturer, the New Ariston GLS series combines Italian design and state of the art features including glass-lined tanks, a 6-year warranty and highest recovery time. 

Installing an Ariston electric mini-tank water heater under the sink puts hot water right where you need it - at the point of use. Lightweight and compact and also the Ariston mini tank heaters are great for those long hot water runs from your tank heater or tankless heater and will shorten the wait time for hot water.

The New Ariston GL2.5S mini-tank electric water heater stores 2.5 gallons of hot water. 

The New Ariston GL4S mini-tank electric water heater stores 4 gallons of hot water. 


Please note: The New Ariston GL2.5S is not the direct replacement for the Ariston GL2.5 as the Ariston Gl2.5S is 10 3/4" in depth and the older Ariston GL2.5 was 10 1/4" deep.  The new Ariston GL4S is not the direct replacement for the Ariston GL4 as the GL4S is 13 1/2" in depth and the older Gl4 was 12 1/4" deep.  The replacement parts for the new Ariston GL2.5S and the GL4S will not work for the older GL2.5 and GL4 mini tank heaters.

  • 6-year warranty on tank 
  • Glass-lined tank for longer life  
  • Mounts on wall or floor 
  • Temperature/pressure relief valve included  
  • Plugs into standard 120 volt outlet
  • Dimensions: GL2.5S-13 3/4" x 13 3/4" x 10 3/4", GL4S-13 3/4" x 13 3/4" x 13 1/2"
  • Recovery at 90 Deg F Rise: 7 GPH 
  • 12.5 AMPS and 1500W Heating Capacity 
  • Temperature Range: 65 Deg F to 145 Deg F  
  • Meets ASHRAE 90.1 Standard
  • Relief Valve = Installed
The new Ariston GL2.5S & GL4S models have many new improvements since they have been upgraded.  The mini tanks have a new temperature adjustment knob on the front of the unit to raise and lower the temperature from 65 Deg F to 145 Deg F.  On the older models you would have to remove the blue oval cover to access the temperature control knob.


The Ariston GL2.5S & GL4S models have a new improved thermostat that features a new sensing probe that is attached to the thermostat and inserts into the cavity of the new element so the heater can adjust temperatures quicker and maintain a more consistent heat.



866-360-9830

Sunday, December 2, 2012

Industrial Circulation / Tankless Heaters


Flow Factor provides in pipe heaters for heating liquids and gases.
Inline pipe heaters are also known as circulation heaters, tankless heaters, in-line heaters or instantaneous heaters.
Industrial circulation heaters are packaged units consisting of a screwplug or flanged immersion heater mounted in a thermally insulated heating chamber for efficient heating of a flowing medium by in-line (tankless) or side-arm operation. Thermocouple sensors can be provided to connect to most any controller. Select from many terminal enclosures, sheath and vessel materials, flanged connections, and controls. Many models in stock.


Circulation heaters provide a ready-made means to install electric heating with a minimal amount of time and labor. This is accomplished by combining heating elements, vessel, insulation, terminal enclosure, mounting brackets and inlet and outlet connections into a complete assembly.
Made from NPT screw plug or ANSI flange heater assemblies mated with a pressure vessel (tank), circulation heaters are designed to heat forced-circulation air, gases or liquids. Ideal for either in-line or side-arm operations, these assemblies direct fluids past FIREBAR® or WATROD™ heating elements, to deliver fast response and even heat distribution.
Applications include: Water Heating, Freeze Protection, Heat Transfer Oil Heating, Fuel Oil Heating, Stea, Air, and Gas Heating and others.




• Watt densities up to 120 W/in2 (18.6 W/cm2)
• Wattages to three megawatts
• UL® and CSA component recognition up to 600VAC (FIREBAR to 480VAC)
• Ratings to ANSI Class 600 pressure class
• Incoloy® sheath temperatures up to 1600°F (870°C)
• Passivated 316 stainless steel sheath temperatures up to 1200°F (650°C)
• Steel sheath temperatures to 750°F (400°C) • Copper sheath temperatures to 350°F (175°C) • Up to 3000psi design pressure
Clean Water Heaters are ideal for heating municipal water for industrial washing and rinsing processes. Other applications include indirect heating of viscous liquids and temperature maintenance of storage tanks.
Light and Medium Weight Oil Heaters are ideal for temperature maintenance and for improving flow characteristics of oils. Heavy or Fuel Oil Heaters will reduce the viscosity, thereby improving flow and process efficiency.
Industrial circulation heaters provide a cost effective means for heating air and common industrial gases such as Argon, Helium and Nitrogen. They can also be used to increase the enthalpy and quality of steam.
Mild corrosive heaters allow the heating of solutions using stainless elements and a passivated stainless pipe body. Highly corrosive solutions and oils can be heated with the low watt density INCOLOY® sheath elements coupled with a passivated Stainless Steel pipe body, providing long service life.


Typical Applications
Water: • Deionized • Demineralized • Clean • Potable • Process • Industrial water rinse tanks •

Lubricating oils at API specified watt densities • Heat transfer oil • Paraffin • Caustic cleaners •
Hydraulic oil, crude, asphalt

Nitrogen, hydrogen and other air/gas systems • Superheating steam

Wattages and Voltages
Watlow routinely supplies circulation heaters from 120 to 600VAC (WATROD to 600VAC) as well as wattages from 500 watts to three megawatts. If required, Watlow will configure circulation heaters with voltages and wattages outside these parameters.

Weatherproof Protective Steel Jacket (Shroud)
To protect circulation heaters from weather or wash-down conditions, fully welded (weatherproof) or partially welded (standard) outer protective steel jackets are available. Standard steel, or made-to-order 304 or 316 stainless steel can be supplied. Jacket diameter is dependent upon thermal insulation thickness.

Options
Stand-off Terminal Enclosures
Stand-off terminal enclosures help protect terminal enclosures against excessive temperatures.
ASME Pressure Vessel Code Welding
Flange or screw plug assemblies can be provided with an ASME Section VIII or Section I, Div. I pressure vessel stamp upon request.
Branch Circuits
Branch circuits are designed for 48 amperes per circuit maximum. Contact a Watlow representative for circuit requirements other than those listed in the stock charts.



Certified Assemblies
CSA, ATEX or IEC Ex certified moisture and/or explosion resistant terminal enclosures protect wiring in hazardous gas environments. These terminal enclosures, covered under CSA file number 61707, ATEX certificate # KEMA 07ATEX0172X or IEC Ex certificate # IEC Ex CSA 09.0010 are available on WATROD flange heaters.

Contact Flow Factor HERE.
216-360-9830



Friday, May 18, 2012

Bosch Electric Tankless Heaters

Bosch Electric Tankless Heaters

Flow Factor Sells Bosch Electric Tankless Heaters

Tankless Heaters are designed to save on electricity and to allow for unlimited hot water.

However, there are variables that need to be considered when purchasing a Tankless heater.

Electric tankless heaters can require larger size wires and panels than standard tank heaters.  At Flow Factor we will go over in detail what the heaters require so you can have a proper installation.  And with a proper installation, the heater will perform as designed.

Variables that affect the outlet water temperature, are heater KW, flow rate and inlet temperature.  These three variables affect all water heating appliances and the potential output temperatures.  A tankless heater heats the water as it flows through the heater.  Each electric (and gas) heater has a maximum heater capability.  For example, the largest heater, the AE125, is about 27 kilo watts.  The AE 125 can heat a flow rate of 2.5 gallons per minute (gpm) 65 degrees.  Meaning it can change the temperature of the water 65 degrees. So if the inlet is 40 degrees the output temperature will be 105.  It cannot produce water hotter than that at that flow rate. If the flow drops to 2.0 gpm than the amount of change increases.  If the flow is more than 2.5, than the amount of change decreases.  At 4.0 gpm, the change is 45 degrees.  A standard USA shower is normally 2.5 gpm.  We can describe all the heaters and their heating capabilities.


Whole House Heaters, showers, wash machines, sinks.
Bosch PowerStar AE125  27 KW Heater, 240 volts, 3x40 amp circuit breakers.

Bosch PowerStar AE115  17 KW Heater, 240 volts, 2x40 amp circuit breakers.
(The AE 115 requires 60+ inlet water temperatures.)

Point of Use Water Heater: Sinks, Dishwashers, low flow shower.
Bosch PowerStar AE12  12 KW Heater, 240 Volts, 1 x 50 amp circuit breaker.  ( RP12 )

Point of Use Water Heaters, Sinks and Dish washers:
Bosch PowerStar AE9.5  9.5 KW Heater, 240 volts, 1 x 40 amp breaker   ( RP9 )

Bosch PowerStar AE7.2  7.2 KW Heater, 240 volts, 1 x 30 amp breaker  ( RP7 )

Bosch PowerStar AE3.4  3.4 KW Heater, 120 volts, 1 x 30 amp breaker  ( RP3 )

The Key to using Tankless Heaters is understanding how they work, how they heater water, their capabilities and their electrical requirements.  With these parameters all being met, the heater will work as advertised and produce the water temperatures needed.