Monday, November 30, 2020

Parker 3-way Solenoid Valves, Series G7

Flow Factor Sells the Mighty Parker G7 3-Way Solenoid valves

For Quotes, please use our Valve Parts Form HERE!








Here are the most popular G7 3-Way valves from Parker

1/8 Inch, NC, Direct Acting, Stainless Steel
30CC02EN7 / 440 PSI
30CC02GN7 / 285 PSI
30CC02LN7 / 160 PSI
30CC02PN7 / 95 PSI

1/4 Inch, NC, Direct Acting, Stainless Steel

30CC04EN7 / 440 PSI
30CC04GN7 / 285 PSI
30CC04LN7 / 160 PSI
30CC04PN7 / 95 PSI

1/8 Inch, NC, Direct Acting, Brass
30LC02EN7 / 440 PSI
30LC02GN7 / 285 PSI
30LC02LN7 / 160 PSI
30LC02PN7 / 95 PSI

1/4 Inch, NC, Direct Acting, Brass
30LC04EN7 / 440 PSI
30LC04GN7 / 285 PSI
30LC04LN7 / 160 PSI
30LC04PN7 / 95 PSI


Coils used on the Above Valves are:
AC VOLTAGES
C7F 120/60, with Conduit, IP67, NEMA 6
C7G 240/60, with Conduit, IP67, NEMA 6
C7E 24/60, with Conduit, IP67, NEMA 6
D7F 120/60, DIN Connection, IP65, NEMA 4X
D7G 240/60, DIN Connection, IP65, NEMA 4X
D7E 24/60, DIN Connection, IP65, NEMA 4X
B7F 120/60, 18 Inch Leads, IP67, NEMA 6
B7G 240/60, 18 Inch Leads, IP67, NEMA 6
B7E 24/60, 18 Inch Leads, IP67, NEMA 6

DC VOLTAGES:
C7A 12vdc, with Conduit, IP67, NEMA 6
C7B 24vdc, with Conduit, IP67, NEMA 6
D7A 12vdc, DIN Connection, IP65, NEMA 4X
D7B 24vdc, DIN Connection, IP65, NEMA 4X
C7A 12vdc, 18 Inch Leads, IP67, NEMA 6
C7B 24vdc, 18 Inch Leads, IP67, NEMA 6

For Quotes, please use our Valve Parts Form HERE!


Flow Factor
216-765-4231
www.flowfactor.com

Parker General Purpose G7 Series Solenoid Valves

Sunday, November 29, 2020

Littelfuse LLC6 Series - Low Level Cutoff

 Low Level Cutoff Liquid Level Control

LIttelfuse LLC6 Series from Flow Factor


The Littelfuse LLC6 Series is a plug-in, single-probe conductive liquid level control designed for low liquid level cutoff protection. It offers a factory fixed time delay of 1 - 60s and is available in input voltages of 24, 120, or 230VAC. LED indicator illuminates whenever the Littelfuse LLC6’s 10A, SPDT output relay is energized. Available with automatic/manual reset or a special manual reset with power outage feature, which auto resets the unit when power is restored and the water level is acceptable. 24VAC and 120VAC units are recognized as limit switches under UL353 (230VAC units are UL508) and CSA certified under Standard 14.

Littelfuse LLC6 Liquid Level Cutoff Relay










Operation: 

Automatic Reset (Reset terminals not connected): When liquid rises to the low level cutoff probe, the output relay and the LED indicator energize. When the liquid falls below low level cutoff probe, the output relay and the LED indicator de-energize after a fixed time delay.

Manual Reset (Reset switch connected)

When the liquid level falls below the low level probe, the output relay and LED de-energize after a fixed time delay. When the liquid level rises to the low level probe, the output relay and LED indicator remain de-energized until the manual reset switch is opened; then they energize immediately

Power Outage Manual Reset (Reset switch connected):

A power outage causes the output relay and LED indicator to de-energize. Upon restoration of power, if the liquid level is above the low level probe, the output relay and LED indicator will re-energize. If the liquid level is below the low level probe, the output relay and LED indicator remain de-energized until the Normally Closed (NC) reset switch is opened.

Features & Benefits:

Isolated 12VAC on Probe >> Prevents Electrolysis

Industry Standard 11 Pin Connection >> No Special Connections

LED indication >> Visual Indication we energized

Power Outage Protection >> Automatically resets after power outage

Littelfuse Part Numbers:

LLC6210F10M: 

24Vac, 10 seconds Delay, 10K Ohms, Automatic/Manual Reset

LLC6410F10M: 

120Vac, 10 seconds Delay, 10K Ohms, Automatic/Manual Reset

LLC643F10M: 

120Vac, 3 seconds Delay, 26K Ohms, Automatic/Manual Reset

LLC6610F10M: 

230Vac, 10 seconds Delay, 5K Ohms, Power Outage Manual Reset

Littelfuse LLC6 Accessories:

BZ1 Panel Mount Kit
NDS-11 11 pin Socket
PSC11 Hold Down Clips
PHST-38QTN Electrode
LLP-24 Threaded Probe (24 inches)

Contact Flow Factor HERE!

Flow Factor
216-765-4231
www.flowfactor.com

Littelfuse LLC6...Littelfuse LLC6...Littelfuse LLC6...Littelfuse LLC6...Littelfuse LLC6

Monday, October 26, 2020

Littelfuse PC-102 Series Pump Controllers

 Littelfuse PC-102 Series Pump Controllers from Flow Factor

For a Quote, Click HERE!

Littelfuse PC-102CICI-DL:

Dual seal-leak detector uses inputs to sense seal failures and energize the output relay. Input logic direct or inverted is DIP switch selectable.

Littelfuse PC-102CICI-LT:

Seal-leak and over-temperature detector uses one input to sense seal failures and the temperature input to detect motor overheating. Configurable to suit various probes. Seal input logic direct or inverted, plus over-temperature trip reset automatic or manual, is DIP switch selectable. 

Littelfuse PC-102 Pump Protection Controller










Littelfuse PC-102 Description

The LIttelfuse PC-102 series is a dual-channel switch that provides dual protection against seal failures and over-temperature in submersible pumping applications.

The relays have two form-C isolated output relays and two LEDs, which illuminate when each associated output relay is energized.

The sensitivity adjustment (4.7k-100kOhms) allows you to define the input impedance at which the output relays will change state. The sensitivity for the over-temperature detector can be set to 4k Ohms with use of the DIP switches.

Littelfuse PC-102 Specifications

Input Characteristics 

Frequency 50/60Hz 

Functional Characteristics: 

Probe Sense Voltage 5vdc pulsed 

Sensitivity 4.7k-100kΩ Sensitivity (for temp) Selectable 4kΩ with DIP switches 

Input Logic Direct or inverted 

Debounce Time Delay 0.5 or 2 seconds 

Output Characteristics:

Relay Output Rating (2 Form C isolated) 

Pilot Duty 180VA @ 120VAC, C150,  General Purpose 5A @ 240VAC 

General Characteristics: 

Temperature Range -20° to 55°C (-4° to 131°F) 

Maximum Input Power 2 W 

Depluggable Connector Phoenix Contact-Series MSTB plugs 

Output Relay Status Indicators LEDs 

Terminal Torque 4.5 in.-lbs. 

Wire range 12-20 AWG 

Standards Passed:

Electrostatic Discharge (ESD) IEC 61000-4-2, Level 3, 6kV contact, 8kV air. 

Radio Frequency Immunity (RFI) IEC 61000-4-3, Level 3, 10V/m 

Fast Transients IEC 61000-4-4, Level 3, 4kV input power 2kV inputs/outputs 

Safety Marks: 

UL UL508 (File #E68520) 

Dimensions H 88.9 mm (3.5”); W 52.93 mm (2.08”); D 59.69 mm (2.35”) 

Weight 0.9 lb. (14.4 oz., 408.23 g) 

Mounting Method 35mm DIN rail or Surface Mount (#6 or #8 screws)

For a Quote, Click HERE!

Flow Factor

216-765-4231

www.flowfactor.com

Littelfuse...PC-102...Littelfuse...PC-102...Littelfuse...PC-102...Littelfuse...PC-102

Saturday, October 24, 2020

5 Channel Pump Controller from Littelfuse - PC-105

PC-105 Series - 5-Channel Pump Controller

from Littelfuse and Flow Factor

For a Quote, Click HERE!

The Littelfuse PC-105 is a 5-channel pump controller designed to handle multiple pump applications. Alternatively, it can operate as a 5-channel switch. The Little Fuse PC-105’s control functions support all of the popular industry standard multi-pump pump-up and pump-down configurations. It can indicate low, high and out-of-sequence alarms and use alternating and non-alternating pump control. The non-alternating pump can be used as a jockey pump or emergency pump. Using the built-in DIP switches, individual pumps can be disabled when taken out of service for repair or maintenance.

Littelfuse PC-105 Five Channel Pump Control









Features:

Compact Design

Low, High and Out of Sequence alarms

Variable time delay/lag pump delay from 2-255 seconds

DuPlex SPS (seperate pump stop) pump control

DuPlex, TriPlex or QuadraPlex pump control

Pump-up or pump-down functions

External Silence, reset and alternation configuration

Five Channel Relay Configuration

DIN rail or surface mountable

SPECS:

120 VAC supply power

50/60 hz frequency

Probe Sense Voltage is 5vdc continuous

Relay Output Rating is 7 am[ps @240 VAC

Max Input Power is 4 watts

12-20 AWG wire size range

Pump In-Rush delay is 2 seconds

Electrostatic discharge  (ESD) is IEC 61000-4-2, Level 3, 6kV contact, 8kV air

Radio Frequency Immunity (RFI) is Level 3, 10V/m

Fast Transients is Level 3, 4kV input power

UL listed UL508

Dimensions: 3.7 x 5.0 x 2.4 inches and 1.2 Pounds

Littelfuse PC-105 Pump Control Wiring












For a Quote, Click HERE!

Flow Factor

216-765-4231

www.flowfactor.com

Littelfuse...PC-105...Littelfuse...PC-105...Littelfuse...PC-105...Littelfuse...PC-105

Wednesday, September 30, 2020

Pump Control from Littelfuse - PC-XXX-LLC Series

 Pump Control from Littelfuse in Small Package - Octal Socket

The Littelfuse PC-xxx-LLC-CZ and PC-xxx-LLC-GM series are liquid level control relays used to control conductive liquid pumping operations in a pump-up or pump-down application. The units come in two different voltage ranges (see specs below). The units have an adjustable sensitivity knob (4.7 k to 100 k ohms) that is set according to the resistance level at which you want the probes (sold separately) to sense the conductive liquid. The units have a built-in debounce time delay that prevents the relay from energizing if the probe resistance momentarily goes above or below the sensitivity set point (due to liquid splashing in the tank). The Little Fuse units operate their internal relay based on inputs from a high and low probe and a common reference (when a conductive tank is used) or common probe (when a non-conductive tank is used). 

Click HERE for a quote

Littelfuse Pump Protection Relay










Littelfuse - PC-XXX-LLC-CZ 

Compatible with Crouzet PNR & PNRU Series Liquid Level

Littelfuse - PC-XXX-LLC-GM

Compatible with Gems 16M Series Liquid Level

Specifications:

Supply Voltage:

PC-100-LLC_CZ ... 95-120VAC

PC-100-LLC_GM ... 95-120VAC

PC-200-LLC_CZ ... 190-240VAC

PC-200-LLC_GM ... 190-240VAC

Frequency 50/60 Hz

Probe Sense Voltage is 5VDC pulsed

Debounce Time Delay is 2 seconds

Probe sensitivity is 4.7k to 100k Adjustable

Output contact rating is 10A @ 240VAC

Approvals are UL and CE

Mounting is via Octal Socket; DIN rail or surface

Octal socket part number is OT08PC




Click HERE for a quote

Flow Factor

216-765-4231

www.flowfactor.com

Littelfuse PC-100-LLC_GM...Littelfuse PC-100-LLC_CZ... Littelfuse

Littelfuse PC-200-LLC_GM...Littelfuse PC-200-LLC-CZ... Littelfuse

Monday, August 31, 2020

Jefferson Solenoid Valves from Flow Factor

Flow Factor stocks and sells Jefferson Valves.

For a Quote, Please use our valve form HERE!

Jefferson Solenoid Valves



















Jefferson's Series Valve Types - General Purpose Valves

Jefferson Valve Series 2026 - Direct Acting for Water, Air, gases and light oils. 
PSI is range is 0-750 and vacuum. Neoprene (BUNA-N), Ethylene Propylene (EPR) and FKM (Viton). 
Valve Sizes are 1/8" and 1/4"

Jefferson Valve Series 1327 - Direct Acting for Water, Air, gases and light oils. PSI is range is 
0-525 and vacuum. Teflon (PTFE), Neoprene (BUNA-N), Ethylene Propylene (EPR) and FKM (Viton).
Valve size is 1/4"  

Jefferson Valve Series 2036 - Pilot Acting for Water, Steam, Air, gases and and light oils. 
PSI is range is 3-150. Teflon (PTFE), Neoprene (BUNA-N), Ethylene Propylene (EPR) and FKM (Viton). 
Valves sizes are 3/8", 1/2", 3/4", 1"

Jefferson General Purpose Valve Series 1335 - Pilot Acting for Water, fuel oil, Air, gases and light oils. 
PSI is range is 0-150. Teflon (PTFE), Neoprene (BUNA-N), Ethylene Propylene (EPR) and FKM (Viton). 
Valves sizes are 3/8", 1/2", 3/4"

Jefferson General Purpose Valve Series 1342 - Pilot Acting for Water, Steam, Air, gases and light oils. 
PSI is range is 3-255. Teflon (PTFE), Neoprene (BUNA-N), Ethylene Propylene (EPR) and FKM (Viton). 
Valves sizes are 3/4", 1", 1-1/2", 2", 2-1/2", 3"

Jefferson General Purpose Valve Series 1390 - Pilot Acting for Water, Steam, Air, gases and light oils. 
PSI is range is 1.5-225. Teflon (PTFE), Neoprene (BUNA-N), Ethylene Propylene (EPR) and FKM (Viton). 
Valves sizes are 1/4", 3/8",  1/2"

Jefferson Valve Series 1314 - Hung Piston for Water, Air, gases and oils. 
PSI is range is 0-225. Teflon (PTFE), Neoprene (BUNA-N), Ethylene Propylene (EPR) and FKM (Viton). 
Valves sizes are 3/4", 1", 1-1/2", 2".

Jefferson Solenoid Valves





















For a Quote, Please use our valve form HERE!

Flow Factor
216-765-4231
www.flowfactor.com

Jefferson Valves...Jefferson Valves...Jefferson Valves...Jefferson Valves...

Thursday, July 30, 2020

Littelfuse Pump Seal Leak Detector

Leak Detector for Pumps from Flow Factor and Littelfuse

The Littelfuse 460-15-100-SLD Seal Leak Detector Protects pumps from damage.

For a quote please use our contact us form HERE!

Littelfuse Pump Saver Seal Leak Detector





















The Littelfuse 460-15-100-SLD is a seal-leak detector to sense seal failures on submersible pumps.

A microcontroller-based relay monitors the shaft seal of a submersible pump motor.  A resistive probe is installed in the sea cavity.  If water leaks into the pump, the resistance measured by the probe decreases. When the resistance drops below the sensitivity set point, the unit will trip and the relay contacts will change state. Output relay logic can be reversed by removing an external jumper.  the unit will automatically reset when the fault is cleared.

Control voltage is 120 VAC
2 form A - SPST contacts
8 amps
IP20  / NEMA 1
LED indicators
UL 508
CE IEC 60947
ONE POUND WEIGHT
Din rail or surface mount.

For a quote please use our contact us form HERE!

Flow Factor
216-765-4231
www.flowfactor.com

Littelfuse...Littelfuse...Littelfuse...Littelfuse...Littelfuse...