Saturday, August 7, 2021

müller co-ax ag valves for Hydrogen

co-ax Valves Designed for Hydrogen Applications
from Flow Factor

For a Quote, please use our co-ax parts form HERE!

coax valves for demanding hydrogen applications






For reliable performance, flexibility and endurance, manufacturers of hydrogen equipment require valves which can deliver an extended cycle life with minimal space requirements and bubble tight shut-off capability.

To meet these stringent requirements, leading manufacturers rely on co-ax® valves, which are not like any other valves you’ve encountered in your career.

The reason why co-ax® valves perform so flawlessly under extreme conditions is that the valves' operation is pressure-independent. In a co-ax® valve, the control element is always pressured balanced, regardless of whether it’s open or closed.

This unique design allows a co-ax® valve to cycle more quickly with positive, leak-free shutoff. As a result, co-ax® valves can last up to ten times longer than conventional ball or diaphragm valves, while requiring virtually no maintenance throughout their extended life cycles.


Why choose co-ax® valves?

In a co-ax® valve, media flows straight through the valve without any significant deviation of the media. Due to the pressure balanced design, the necessity of an internal pilot orifice is eliminated. This makes the valve less susceptible to contamination and solid particles and provides higher flow rates with a minimized pressure loss.

The combination of compact size, bubble tight design and long cycle life makes co-ax® valves the ideal replacement for actuated ball valves, angle-seat valves, motor driven valves and conventional solenoid valves especially in remote or difficult to service applications.

co-ax® valves have only one moving part which greatly reduces actuation forces and operational stresses. As a result, co-ax® valves can last up to ten times longer than conventional valves, requiring virtually no maintenance throughout their extended cycle life.

co-ax valves for hydrogen applications









Key Features

1. Pressure Balanced Design
2. Bubble-Tight Shutoff
3. Compact Design
4. High Flow Rate
5. Fast Switching Times
6. High Cycle Life

Typical Hydrogen Applications for co-ax® valves

  • Production

  • Storage/Transport

  • Refueling
  • Power Generation

  • Test Benches

  • Industry/Chemical


For a Quote, Please use our co-ax parts form HERE!

Flow Factor
216-765-4231
www.flowfactor.com

co-ax...coax...coaxial...co-ax...coax...coaxial

Monday, November 30, 2020

Parker 3-way Solenoid Valves, Series G7

Flow Factor Sells the Mighty Parker G7 3-Way Solenoid valves

For Quotes, please use our Valve Parts Form HERE!








Here are the most popular G7 3-Way valves from Parker

1/8 Inch, NC, Direct Acting, Stainless Steel
30CC02EN7 / 440 PSI
30CC02GN7 / 285 PSI
30CC02LN7 / 160 PSI
30CC02PN7 / 95 PSI

1/4 Inch, NC, Direct Acting, Stainless Steel

30CC04EN7 / 440 PSI
30CC04GN7 / 285 PSI
30CC04LN7 / 160 PSI
30CC04PN7 / 95 PSI

1/8 Inch, NC, Direct Acting, Brass
30LC02EN7 / 440 PSI
30LC02GN7 / 285 PSI
30LC02LN7 / 160 PSI
30LC02PN7 / 95 PSI

1/4 Inch, NC, Direct Acting, Brass
30LC04EN7 / 440 PSI
30LC04GN7 / 285 PSI
30LC04LN7 / 160 PSI
30LC04PN7 / 95 PSI


Coils used on the Above Valves are:
AC VOLTAGES
C7F 120/60, with Conduit, IP67, NEMA 6
C7G 240/60, with Conduit, IP67, NEMA 6
C7E 24/60, with Conduit, IP67, NEMA 6
D7F 120/60, DIN Connection, IP65, NEMA 4X
D7G 240/60, DIN Connection, IP65, NEMA 4X
D7E 24/60, DIN Connection, IP65, NEMA 4X
B7F 120/60, 18 Inch Leads, IP67, NEMA 6
B7G 240/60, 18 Inch Leads, IP67, NEMA 6
B7E 24/60, 18 Inch Leads, IP67, NEMA 6

DC VOLTAGES:
C7A 12vdc, with Conduit, IP67, NEMA 6
C7B 24vdc, with Conduit, IP67, NEMA 6
D7A 12vdc, DIN Connection, IP65, NEMA 4X
D7B 24vdc, DIN Connection, IP65, NEMA 4X
C7A 12vdc, 18 Inch Leads, IP67, NEMA 6
C7B 24vdc, 18 Inch Leads, IP67, NEMA 6

For Quotes, please use our Valve Parts Form HERE!


Flow Factor
216-765-4231
www.flowfactor.com

Parker General Purpose G7 Series Solenoid Valves

Wednesday, July 1, 2020

Parker FCD valve 20LC04PN7C7F

FLOW FACTOR Parker 20LC04PN7C7F

Flow Factor has Parker Skinner FCD valve in STOCK.
New and in original Packaging

Valve has specs of:
120/60 coil voltage
1/4 pipe connections.
Normally Closed
375 PSI Max.
185ºF Max Media Temperature
Repair Kit # 7R004/C7F (not in stock)

Unit price is $50.00 net each

Please call to order or email an order to info@flowfactor.com

PARKER 2OLC04PN7C7F / 2OLC04PN7C7F






















Please call to order or email an order to info@flowfactor.com

Flow Factor
216-765-4231
www.flowfactor.com

20LC04PN7C7F .. 20LCO4PN7C7F .. 2OLC04PN7C7F ... 20LC04PN7C7F .. 20LCO4PN7C7F .. 2OLC04PN7C7F 

Saturday, May 30, 2020

Jefferson 1342 2-Way Valves for Industrial Uses

Flow Factor Sells Jefferson series 1342 Solenoid Valves


The 1342 Jefferson series valves in 120/60 AC volts are used for general industrial or commercial applications for controlling the flow of air, oil, water or other non-corrosive fluid or media. Available in sizes from 3/4 to 3 inch the 1342 can solve most 2-way solenoid valve issues. Valves can have GP coils, Watertight coils or hazardous area coils.


Introduction
Solenoid valves are always present in every current industrial process operating with fluids such as liquids, steam or gases, serving as an automation or safety device.
Selecting them properly allows to save money and guarantees the best performance and long useful life for the system.


General purpose valves
These are used in a great variety of systems and different industrial areas that handle water, air, steam, light oils, neutral gases and cryogenic fluids, from vacuum to high pressure and high temperature.
Some application examples are: automatic petrol and beverage pumps, sector-programmed park irrigation, sown land, dancing water fountains, oxyacetylene welding equipments, electric welding under inert atmosphere, fire-extinguisher systems, liquid or gas dosing, liquid level regulation, packing machines, water treatment systems, pneumatic expellers, car washing machines, building exterior cleaning machines, nickel-plating process, galvanization, coffee machines, car systems against theft or gas selection systems, air heating systems, hot water, steam, hot oils, laboratory or industrial cryogenic systems, low and high vacuum regulation, ink drying systems, etc.

1342  2-way solenoid valves for General purpose Applications

Applications include


Pumps. Laundry equipments.
Irrigation. Compressors. Pollution controls. Heating with medium or high pressure steam. Autoclaves. Industrial laundry equipments. Spraying. Irrigation.
Air dryers. water treatment. 
  

Options:
•Energized coil indicator light.
•Explosion and / or weather proof coils and housings.
•Manual operator on main passage. •Manual operator on pilot orifice. 


ZC1342BV06T Brass Valve by Jefferson, 120/60, 3/4 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.C., viton

ZC1342BV08T Brass Valve by Jefferson, 120/60, 1 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.C., viton

ZC1342BV12T Brass Valve by Jefferson, 120/60, 1 1/2 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.C., viton

ZC1342BV16T Brass Valve by Jefferson, 120/60, 2 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.C., viton

ZC1342BV20T Brass Valve by Jefferson, 120/60, 2 1/2 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.C., viton

ZC1342BV24T Brass Valve by Jefferson, 120/60, 3 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.C., viton
ZC1342BV06INAT Brass Valve by Jefferson, 120/60, 3/4 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.O., viton

ZC1342BV08INAT Brass Valve by Jefferson, 120/60, 1 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.O., viton

ZC1342BV12INAT Brass Valve by Jefferson, 120/60, 1 1/2 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.O., viton
ZC1342BV16INAT Brass Valve by Jefferson, 120/60, 2 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.O., viton
ZC1342BV20INAT Brass Valve by Jefferson, 120/60, 2 1/2 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.O., Viton
ZC1342BV24INAT Brass Valve by Jefferson, 120/60, 3 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.O., viton

To get a quote on any Jefferson part, 
go to our Jefferson Parts Form HERE!
Flow Factor
216-765-4231
www.flowfactor.com
Jefferson Valves 1342...Jefferson Valves 1342...Jefferson Valves 1342

Friday, August 16, 2019

Parker G7 Solenoid Valves

Parker General Purpose G7 Series Solenoid Valves from Flow Factor
The Evolution of Gold Ring and Skinner Valves

For Quotes, please use our Valve Parts Form HERE!

Benefits 
Industry-Leading Performance 
High Pressures 
High Flows 
High Temperatures 
Corrosion Resistant 
Environmentally Resistant 

Specifications 

• Port Sizes: 1/8" - 3/8" NPT 
• Pressures: Up to 2200 psi 
• Flows: Up to 1.06 Cv 

Premium Construction 

• 303 Stainless Steel 
• Lead-Free Brass* 
• IP67, Thermal Shock-Resistant Solenoid Coil 
• Engineered for Long Life 
• Proven Gold Ringand Skinner® Fundamentals 

Commonly Valve Part Numbers
2-Way-Normaly Closed-Direct Acting-AC Coils-Stainless
20CC02GV7 
20CC02PV7 
20CC02QV7 
20CC04GP7 
20CC04GV7 
20CC04LV7 
20CC04PV7 
20CC04QV7 
20CC04TV7 
20CC06TV7 
20CC061V7 
2-Way-Normaly Closed-Direct Acting-DC Coils- Stainless
20CC02GV7 
20CC02PV7 
20CC02QV7 
20CC04GV7 
20CC04LV7 
20CC04PV7 
20CC04QV7 
20CC04TV7 
20CC06QV7 
20CC06TV7 




















2-Way-Normaly Closed-Direct Acting-AC Coils-Brass
20LC02PN7 
20LC04GN7 
20LC04LN7 
20LC04PN7 
20LC04QN7 
20LC04TN7 
20LC041N7 
20LC06TN7 
20LC061N7 
2-Way-Normaly Closed-Direct Acting-DC Coils-Brass
20LC02PN7 
20LC04GN7 
20LC04LN7 
20LC04PN7 
20LC04QN7 
20LC04TN7 
20LC06QN7 
20LC06TN7 
Coils used on the Above Valves are:
For AC Valves;
C7F 120/60, with Conduit, IP67, NEMA 6
C7G 240/60, with Conduit, IP67, NEMA 6
C7E 24/60, with Conduit, IP67, NEMA 6
D7F 120/60, DIN Connection, IP65, NEMA 4X
D7G 240/60, DIN Connection, IP65, NEMA 4X
D7E 24/60, DIN Connection, IP65, NEMA 4X
B7F 120/60, 18 Inch Leads, IP67, NEMA 6
B7G 240/60, 18 Inch Leads, IP67, NEMA 6
B7E 24/60, 18 Inch Leads, IP67, NEMA 6

For DC Valves:
C7A 12vdc, with Conduit, IP67, NEMA 6
C7B 24vdc, with Conduit, IP67, NEMA 6
D7A 12vdc, DIN Connection, IP65, NEMA 4X
D7B 24vdc, DIN Connection, IP65, NEMA 4X
C7A 12vdc, 18 Inch Leads, IP67, NEMA 6
C7B 24vdc, 18 Inch Leads, IP67, NEMA 6

For Quotes, please use our Valve Parts Form HERE!



Flow Factor
216-765-4231
www.flowfactor.com

Parker General Purpose G7 Series Solenoid Valves

Sunday, August 11, 2019

Picking a Valve - TOMS PAVE

Picking a Solenoid Valve using TOMS PAVE from Flow Factor

An easy way to help pick out a valve is an acronym TOMSPAVE.

Use the Flow Factor Valve Parts form for a quote.  Click HERE!

T = Type of valve
2-way, 3-way, 4-way

O = Operation
Normally Closed, Normally Open, Diverting, Universal

M = Media
Water, Oil, Gas, Steam, Other

S = Size
1/8, 1/4, 1/2, 3/4, 1, 1.5, 2, 3 Inch NPT

P = Pressure
PSI required in your application

A = Ambient Situation
Wet, Hazardous, Temperature, Indoor, Outdoor

V= Voltage
24/60, 120/60, 240/60, 480/60, 12vdc, 24vdc, 120vdc, Other

E = Extras
Mounting Bracket, Timer, Spade Tabs, DIN coil, Screw Terminals

Use the Flow Factor Valve Design Form to help pick your valve.

Use the Flow Factor Valve Parts Form for a quote.


Flow Factor
216-765-4231
www.flowfactor.com

Tuesday, June 4, 2019

Aircraft Fire Trainer with co-ax valves

Flow Factor and  co-ax® valves application


Get a quote for co-ax®
 HERE!

Aircraft Fire Trainer

Aircraft Fire Trainer are designed to recreate a series of different emergency scenarios, including interior and exterior incident fires and large-scale fuel spill fires on airplanes, all managed by an adjacent control tower and PC control station. Inside, a series of fires can be accessed by a series of doors on multiple levels, helping to develop realistic rescue scenarios.
Aircraft Fire Trainers are fully programmable, and automatically respond to the application of extinguishing media, for a realistic fire response.
Fire simulations utilize clean burning propane. Alternately, "dual-fueled" fire simulations are available that burn either kerosene for maximum realism or propane for environmental compliance.






Summary
co-ax® valves are used to release propane or liquid fuel to the plane mock-up shown in the picture. The fuel is ignited and the fire is extinguished by fire fighting trainees. They use water to extinguish the flames. Water also keeps the mock-up from distorting. The co-ax® valves are submerged under the gravel and water in the bottom of the pool.

Why are co-ax® valves the preferred choice?

  • Positive shut-off.
  • Fast open/closing speed  < 100 milliseconds required.
  • Compact size.
  • Valves (externally controlled) can be buried in a pit.

Typical co-ax® valves being used in this application

  • VMK 20 NC
  • VFK 25 NC
  • MK 10 NC 1E

Get a quote for co-ax®
 HERE!

Flow Factor
216-765-4231
www.flowfactor.com

CO-AX VALVES INC. IS PART OF THE MÜLLER CO-AX GROUP

Sunday, June 2, 2019

co-ax® valves for polyol applications

co-ax® valves from Flow Factor

Get a quote for co-ax HERE!

co-ax® valves for polyol applications


co-ax® valves being used in this application

  • PCS-1 10, PCS-1 15, PCS-2 10, PCS-2 15, PCS-3 15, PCB-1 10, PCD-1 10 - cartridge valves, externally controlled KB 15 direct acting valves
  • VMK-H 15, VMK-H 15 DR, VMK-H 20, VMK-H 25, VSV-M 50


co-ax® valves are used to inject polyol, which then blends together with isocyanates to create a chemical compound called polyurethanes.
The mixture of the chemicals form molds for many different applications, which are used to create mattresses, foam insulation for refrigerators and freezers, home and automotive seats, elastomeric shoe soles, fibers (e.g. Spandex), and adhesives.
Isocyanates, when exposed to air, tend to form crystals that generate premature wear in valves, especially those containing abrasive fillers and they are equally destructive to the seals and seat.
Multiple co-ax® valves have been designed and sold for polyol applications. The fast actuation speeds of the co-ax® valve combined with high cycle life and virtually no maintenance are key advantages for this application.











Why are co-ax® valves the preferred choice?

  • Fast actuation
  • Engineered for long life (high cycle life)
  • Pressure balanced design


Get a quote for co-ax HERE!

Flow Factor
216-765-4231
www.flowfactor.com

CO-AX VALVES INC. IS PART OF THE MÜLLER CO-AX GROUP

Saturday, March 30, 2019

Parker Lead Free Solenoid Valves

Lead Free Water Valves from Flow Factor
Parker Water, Hot Water, and Steam Solenoid Valves

For a Quote, Contact us HERE!









Product Features:
Parker’s Fluid Control Division (FCD) has a long history in
manufacturing industry leading steam and hot water valves.
FCD has expanded this offering to include Lead Free Brass
(containing less than 0.25% lead), meeting the SDWA, Section
1417(d) requirements for brass.
Our valves are specifically designed to withstand harsh
application conditions. The steam valves have an integral
stainless steel orifice for long life and durability.

Typical Applications:
• Industrial Dish Washing
• Industrial Laundry
• Commercial Cooking
• Steam Tables
• Sterilizers / Autoclaves
• Dry Cleaning
• Steam Presses


Product Specifications
Mechanical
Valve Type:
2-Way Normally Closed
2-Way Normally Open
Media:
Water, Hot Water, Steam
Porting:
3/8" NPT to 1" NPT
Wetted Materials:
Body/Cover:
Lead Free Brass (<0 .25="" p="">
Operator:
300 & 400 Series SS, Copper
Seals:
PTFE & EPDM

Electrical
Voltage:
AC: 24/60, 120/60-110/50,
240/60-220/50
DC: 12 & 24

Connections:
1/2" Conduit with leads,
DIN 43650 Form A
Temperature Class:
Water & Hot Water – Class F
Steam – Class H
Agency Approvals:
UL/CSA

Performance
Maximum Media Temp:
Water: Up to 180°F
Steam: Up to 353°F
Max Operating Pressure Differential:
Up to 275 psi
Orifice sizes:
1/2" to 1"
Flow Factor (Cv):
Up to 12.2

Parker Lead Free Hot Water Valve Part Numbers
06F25CL332ACF, 08F25CL332ACF, 12F25CL348ACF, 16F25CL364ACF, 08F25CL332ACF4C05, 12F25CL348ACF4C05, 16F25CL364ACF4C05, 06F25CL332A3F, 08F25CL332A3F, 12F25CL348A3F, 16F25CL364A3F, 06F25OL332ACF, 08F25OL332ACF, 12F25OL348ACF, 16F25OL364ACF, 06F25OL332A3F, 08F25OL332A3F, 12F25OL348A3F, 16F25OL364A3F


Parker Lead Free Steam Valve Part Numbers
06FS5CL432ACH, 08FS5CL432ACH, 12FS5CL448ACH, 16FS5CL464ACH, 08FS5CL432ACH4C05, 12FS5CL448ACH4C05, 16FS5CL464ACH4C05

For a Quote, Contact us HERE!

Flow Factor
216-765-4231

Parker Lead Free Hot Water and Steam Valves for Industry.

Sunday, February 24, 2019

Parker 71395SN2KVJ1N0L111C2 3-Way Valve

Flow Factor Stocks the Parker 3-Way Solenoid Valve 71395SN2KVJ1N0L111C2

Flow Factor stocks the Parker 7000 series three way solenoid valve 71395SN2KVJ1NOL111C2

Applications for this Parker Skinner 3-way solenoid valve include; pilot valve for an air valve, pilot valve for cylinders, diverting valve for air or water, and other general purpose valve uses.

The Parker 71395SN2KVJ1N0L111C2 is a 1/4 inch valve, rated to 125 PSI and css with a 24vdc NEMA 4 coil.  The coil can be changed to 12 vdc, 24/60, 120/60 or 240/60.



71395SN2KVJ1N0L111C2

Parker 71395SN2KVJ1N0L111C2
















Buy the Parker Valve 71395SN2KVJ1NOL111C2 HERE!

Get Parker quotes HERE.

Flow Factor
216-765-4231
www.flowfactor.com

Thursday, January 24, 2019

Solenoid Valve Trouble Shooting Guide

Marvin the Maintenance Man wants to help you troubled shoot Solenoid Valves.

BUY valves HERE!  Contact Flow Factor HERE!


Whoops: "Throw the extra parts away."  All parts must be assembled correctly for the valve to operate properly.

Whoops: "I only hit the valve ONCE with my hammer." A hammer is not a trouble shooting tool. Valve abuse contributes to the most reported problems.

Whoops:  "We don't need a special wrench; I'll find something to take the valve apart". Special tools for the valve disassembly may be needed.  Pipe wrenches etc. will damage parts.

Whoops: "I'll add more teflon tape."  Gobs of tape will block internal passages and interfere with seating. (These are not ball valves).

Whoops:  I forgot to turn on the electricity." "I forgot to open the hand valve." "A strainer takes up too much room." Beware of Marvin Maintenance.

Whoops:  "It's only 10 PSI more than maximum operating pressure."  "It's almost at the minimum operating pressure." " Voltage is not that important." Name Plate Data Applies.

Whoops: "I throw them away." Installation and maintenance instruction sheets have trouble shooting hints, maintenance notes and assembly instructions; etc." Do Not Throw Them Away.

Whoops: "So I piped it up backwards and/or upside down." Proper Mounting is IMPORTANT.

Whoops: "We're out of 1 inch pipe, so I used 1/4 inch pipe." Valves, especially 3-way and 4-way valves,  should not be restricted.

Whoops: "Well it operated pretty well for the past 20 years."  A maintenance program is suggested.

Whoops: "The Valve is defective."  "The Valve does not operate." "The Valve Failed."  Not very descriptive. Find out part number and get application data.

Whoops:  "I need the silver thing." = Solenoid Sub Base Assembly.
                "I need an orifice." = Not a spare part. Buy a new valve.
                "I need  gasket." =  Specify which one.
                "I need  plunger." = Core Assembly.
                "I need a solenoid." = Coil

Whoops:  "What is a Kit?" Do not replace individual parts.  Use a kit to replace all the wearable parts and restore the valve.  Call for kit # or look on name plate.

Whoops: "Buy any two way valve, they're are all the same." Misapplication problems can be avoided.

Whoops: "I can trouble shoot anything!"  We believe you Marvin.

BUY valves HERE!

TROUBLE SHOOTING 2 WAY VALVES

Trouble shooting 2-way DIRECT ACTING Solenoid Valves
Normally Closed Valve Fails to OPEN when energized:
1. No Voltage
2. Low Voltage
3. Burned Out Coil
4. Excessive Pressure
5. Binding Core
6. Swollen or cut resilient disc
7. No Pressure to valve

Trouble shooting 2-way DIRECT ACTING Solenoid Valves
Normally Closed Valve Fails to CLOSE when energized:
1. Faulty control circuit
2. Improper Installation
3. Scale of foreign matter
4. Damaged Seat or Disc
5. Binding Core
6. Damaged or Missing Spring

Trouble shooting 2-way DIRECT ACTING Solenoid Valves
Excessive Solenoid NOISE when energized:
1. Low Voltage
2. Loose Solenoid Parts
3. Foreign Matter on core or Plug Nut
4. Worn Core or plug nut
5. Incorrect or damaged spring


Trouble shooting 2-way PILOT OPERATED Solenoid Valves
Normally Closed Valve Fails to Open when energized:
1. No Voltage
2. Low Voltage
3. Burned Out Coil
4. Excessive Pressure
5. Binding Core
6. Swollen or cut resilient disc
7. No Pressure to valve
8. Low Pressure
9. Ruptured diaphragm or damaged piston ring
10. Plugged or restricted pilot orifices



Installation Tips for 3 and 4 way Pilot Operated Valves

1. Do Not Select Oversized Valves. Size Carefully for Flow and Cylinder speed. For Economy and reliable operation.

2. Use Full Area Lines in Pressure and Exhaust.

3. I.D. (Internal Diameter) of lines and fittings must be larger than orifice.

4. Differential Between Pressure and Exhaust must exceed the minimum at all times.

5. Do Not Meter Flow in Pressure or Exhaust Lines.

6. Install Speed Control Valves in the Cylinder Lines Only.

7. Avoid Pressure Regulators if Possible. If essential, the regulator must have flow capacity to maintain the MINIMUM Differential at all times.

8. Hydraulic Pumps or Air Reservoirs must have adequate capacity to maintain the minimum DeltaP at all times.

9. Pressure Differential may be measured by means of gages installed immediately at the pressure and exhaust connections.

10. Do Not Mistake a Faulty Cylinder for a valve malfunction, Isolate the Cylinder.

BUY valves HERE!

Get a solenoid Valve Quotation HERE!

Flow Factor
216-765-4231
www.flowfactor.com

ASCO Solenoid Valves - Parker Solenoid Valves - Jefferson Valves

Monday, August 13, 2018

Parker Solenoid Valves and Types of Fluids

Parker Solenoid Valves from Flow Factor

How Fluid Type Affects Solenoid Valve Choices

In industrial applications, the successful transfer of fluids requires different types of valves to open and close the flow. Solenoid valves are a popular choice because they offer rapid automatic opening and closing, remote control and high process security.

Fluid considerations

The type of fluid being used in a production process may potentially reduce the operational lifetime of a solenoid valve. Why so? Well, many parts of the valve, such as the body, mechanism and seals, will be in direct contact with the fluid. In diverse industrial applications, the fluids may include aggressive media like cleaning agents and reagents used in food processing, car washing and industrial washing applications. These fluids require the careful selection of a solenoid valve to do the job safely, reliably and effectively.  
The materials used in the valve should not influence the chemical composition of the fluid, i.e. breakdown and contaminate, especially in the food and beverage industry. Here, for processes such as the cleaning of bottles or machinery, a solenoid valve using lead-based materials could not be specified for obvious reasons. Instead, stainless steel is more appropriate, which is the case in the medical and pharmaceutical sectors too.

Impact on choice

It is important to avoid comparing solenoid valves, feature by feature, when looking to specify the right product for an installation. However, on many occasions the specific application must guide the common sense choice. For instance, where maximum working life is required, such as in outdoor service scenarios, then corrosion resistance must be a priority. Similarly, one must also factor in the presence of an explosion-risk environment, such as those found in the oil and gas and petrochemical sectors.
An example of a solenoid valve developed for use in challenging applications where aggressive chemicals or fluids are present is the Parker 221G series stainless steel solenoid valve. The use of high-grade 316L stainless steel as the valve body material is significant as in harsh environments it gives increased system reliability and, in turn, improved operational performance and productivity. In fact, it has shown to deliver 30% more life on average (depending on the application) versus some other technologies.
Offering wide-ranging chemical compatibility is vital, and the 221G series valve has been designed to be 30% more resistant in corrosive environments. The use of fluoroelastomer (FKM) seals aids dependable operation under severe chemical conditions and at higher temperatures where many other seal materials may perish or otherwise lose their integrity. Degrading seals can lead to fluid leaks and the associated safety risks and costly downtime. FKM seals are especially well suited to arduous conditions with petroleum fuels, mineral-based hydraulic fluids or other solvents present. 

Flow Factor
216-765-4231

Tuesday, July 3, 2018

Over Stock Parker Angle Body Valves

Flow Factor
Parker Series 800 Angle Body Valves in Stainless and Bronze
These Valves are new and unused surplus Air Actuated 2-Way valves

Buy OVERSTOCK parts HERE.


Parker 810VBN24T330BH000
PARKER Angle Body Valve

810VBN24T330BH000
0-102 PSI / 0-7 bar
Actuation PSI 51-145
1.5 inch ports
2-way Normally Closed Valve
Bronze Body




 810VBN08T220BH000

0-232 PSI / 0-16 bar
Actuation PSI 36-54
1/2 inch ports
2-way Normally Closed Valve
Bronze Body



Other Parker 810 series Angle Body valves in stock:

810VBN08T320BH000
810VBN12T120BH000
810VBN12T320BH000
810VBN16T220BH000
810VBN16T320BH000
810VBN24T130BH000
810VSN12T120BH000
810VSN12T320BH000
810VSN16T120BH000
810VSN16T320BH000
810VSN24T130BH000
810VSN24T330BH000

Buy OVERSTOCK parts HERE.


www.flowfactor.com
866.360.9830




Sunday, June 17, 2018

Valcor Valves Overstock Surplus

Over Stock Surplus Valcor Valves at Flow Factor

Buy HERE!


Valcor Solenoid Valve SV54C19P1A 120/60 - 1/4 inch
Valcor Valve SV54C19PIA 115/60 solenoid valve. Valve size is 1/4 inch. The Jefferson Valve SV54C19P1A is a Normally closed valve 120 max psi and buna N seals



Valcor Valve SV54C19PIA 115/60


Valcor Solenoid Valve SV321GF02N5CG4 120/60 - 3/8 inch
Valcor Valve SV321GF02N5CG4 115/60 solenoid valve. Valve size is 1/4 inch. The Valcor Valve SV321GF02N5CG4 is a Normally closed valve 4-200 psi fr Air and water and 4-150 for light oils and valve has buna N seals
Valcor part number is SV321GF02N5CG4


Valcor part number is SV321GF02N5CG4