Showing posts with label ASCO. Show all posts
Showing posts with label ASCO. Show all posts

Saturday, August 7, 2021

müller co-ax ag valves for Hydrogen

co-ax Valves Designed for Hydrogen Applications
from Flow Factor

For a Quote, please use our co-ax parts form HERE!

coax valves for demanding hydrogen applications






For reliable performance, flexibility and endurance, manufacturers of hydrogen equipment require valves which can deliver an extended cycle life with minimal space requirements and bubble tight shut-off capability.

To meet these stringent requirements, leading manufacturers rely on co-ax® valves, which are not like any other valves you’ve encountered in your career.

The reason why co-ax® valves perform so flawlessly under extreme conditions is that the valves' operation is pressure-independent. In a co-ax® valve, the control element is always pressured balanced, regardless of whether it’s open or closed.

This unique design allows a co-ax® valve to cycle more quickly with positive, leak-free shutoff. As a result, co-ax® valves can last up to ten times longer than conventional ball or diaphragm valves, while requiring virtually no maintenance throughout their extended life cycles.


Why choose co-ax® valves?

In a co-ax® valve, media flows straight through the valve without any significant deviation of the media. Due to the pressure balanced design, the necessity of an internal pilot orifice is eliminated. This makes the valve less susceptible to contamination and solid particles and provides higher flow rates with a minimized pressure loss.

The combination of compact size, bubble tight design and long cycle life makes co-ax® valves the ideal replacement for actuated ball valves, angle-seat valves, motor driven valves and conventional solenoid valves especially in remote or difficult to service applications.

co-ax® valves have only one moving part which greatly reduces actuation forces and operational stresses. As a result, co-ax® valves can last up to ten times longer than conventional valves, requiring virtually no maintenance throughout their extended cycle life.

co-ax valves for hydrogen applications









Key Features

1. Pressure Balanced Design
2. Bubble-Tight Shutoff
3. Compact Design
4. High Flow Rate
5. Fast Switching Times
6. High Cycle Life

Typical Hydrogen Applications for co-ax® valves

  • Production

  • Storage/Transport

  • Refueling
  • Power Generation

  • Test Benches

  • Industry/Chemical


For a Quote, Please use our co-ax parts form HERE!

Flow Factor
216-765-4231
www.flowfactor.com

co-ax...coax...coaxial...co-ax...coax...coaxial

Monday, August 31, 2020

Jefferson Solenoid Valves from Flow Factor

Flow Factor stocks and sells Jefferson Valves.

For a Quote, Please use our valve form HERE!

Jefferson Solenoid Valves



















Jefferson's Series Valve Types - General Purpose Valves

Jefferson Valve Series 2026 - Direct Acting for Water, Air, gases and light oils. 
PSI is range is 0-750 and vacuum. Neoprene (BUNA-N), Ethylene Propylene (EPR) and FKM (Viton). 
Valve Sizes are 1/8" and 1/4"

Jefferson Valve Series 1327 - Direct Acting for Water, Air, gases and light oils. PSI is range is 
0-525 and vacuum. Teflon (PTFE), Neoprene (BUNA-N), Ethylene Propylene (EPR) and FKM (Viton).
Valve size is 1/4"  

Jefferson Valve Series 2036 - Pilot Acting for Water, Steam, Air, gases and and light oils. 
PSI is range is 3-150. Teflon (PTFE), Neoprene (BUNA-N), Ethylene Propylene (EPR) and FKM (Viton). 
Valves sizes are 3/8", 1/2", 3/4", 1"

Jefferson General Purpose Valve Series 1335 - Pilot Acting for Water, fuel oil, Air, gases and light oils. 
PSI is range is 0-150. Teflon (PTFE), Neoprene (BUNA-N), Ethylene Propylene (EPR) and FKM (Viton). 
Valves sizes are 3/8", 1/2", 3/4"

Jefferson General Purpose Valve Series 1342 - Pilot Acting for Water, Steam, Air, gases and light oils. 
PSI is range is 3-255. Teflon (PTFE), Neoprene (BUNA-N), Ethylene Propylene (EPR) and FKM (Viton). 
Valves sizes are 3/4", 1", 1-1/2", 2", 2-1/2", 3"

Jefferson General Purpose Valve Series 1390 - Pilot Acting for Water, Steam, Air, gases and light oils. 
PSI is range is 1.5-225. Teflon (PTFE), Neoprene (BUNA-N), Ethylene Propylene (EPR) and FKM (Viton). 
Valves sizes are 1/4", 3/8",  1/2"

Jefferson Valve Series 1314 - Hung Piston for Water, Air, gases and oils. 
PSI is range is 0-225. Teflon (PTFE), Neoprene (BUNA-N), Ethylene Propylene (EPR) and FKM (Viton). 
Valves sizes are 3/4", 1", 1-1/2", 2".

Jefferson Solenoid Valves





















For a Quote, Please use our valve form HERE!

Flow Factor
216-765-4231
www.flowfactor.com

Jefferson Valves...Jefferson Valves...Jefferson Valves...Jefferson Valves...

Saturday, May 30, 2020

Jefferson 1342 2-Way Valves for Industrial Uses

Flow Factor Sells Jefferson series 1342 Solenoid Valves


The 1342 Jefferson series valves in 120/60 AC volts are used for general industrial or commercial applications for controlling the flow of air, oil, water or other non-corrosive fluid or media. Available in sizes from 3/4 to 3 inch the 1342 can solve most 2-way solenoid valve issues. Valves can have GP coils, Watertight coils or hazardous area coils.


Introduction
Solenoid valves are always present in every current industrial process operating with fluids such as liquids, steam or gases, serving as an automation or safety device.
Selecting them properly allows to save money and guarantees the best performance and long useful life for the system.


General purpose valves
These are used in a great variety of systems and different industrial areas that handle water, air, steam, light oils, neutral gases and cryogenic fluids, from vacuum to high pressure and high temperature.
Some application examples are: automatic petrol and beverage pumps, sector-programmed park irrigation, sown land, dancing water fountains, oxyacetylene welding equipments, electric welding under inert atmosphere, fire-extinguisher systems, liquid or gas dosing, liquid level regulation, packing machines, water treatment systems, pneumatic expellers, car washing machines, building exterior cleaning machines, nickel-plating process, galvanization, coffee machines, car systems against theft or gas selection systems, air heating systems, hot water, steam, hot oils, laboratory or industrial cryogenic systems, low and high vacuum regulation, ink drying systems, etc.

1342  2-way solenoid valves for General purpose Applications

Applications include


•Pumps. Laundry equipments.
•Irrigation. Compressors. Pollution controls. •Heating with medium or high pressure steam. •Autoclaves. Industrial laundry equipments. •Spraying. Irrigation.
•Air dryers. water treatment. 
  

Options:
•Energized coil indicator light.
•Explosion and / or weather proof coils and housings.
•Manual operator on main passage. •Manual operator on pilot orifice. 


ZC1342BV06T Brass Valve by Jefferson, 120/60, 3/4 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.C., viton

ZC1342BV08T Brass Valve by Jefferson, 120/60, 1 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.C., viton

ZC1342BV12T Brass Valve by Jefferson, 120/60, 1 1/2 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.C., viton

ZC1342BV16T Brass Valve by Jefferson, 120/60, 2 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.C., viton

ZC1342BV20T Brass Valve by Jefferson, 120/60, 2 1/2 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.C., viton

ZC1342BV24T Brass Valve by Jefferson, 120/60, 3 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.C., viton
ZC1342BV06INAT Brass Valve by Jefferson, 120/60, 3/4 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.O., viton

ZC1342BV08INAT Brass Valve by Jefferson, 120/60, 1 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.O., viton

ZC1342BV12INAT Brass Valve by Jefferson, 120/60, 1 1/2 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.O., viton
ZC1342BV16INAT Brass Valve by Jefferson, 120/60, 2 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.O., viton
ZC1342BV20INAT Brass Valve by Jefferson, 120/60, 2 1/2 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.O., Viton
ZC1342BV24INAT Brass Valve by Jefferson, 120/60, 3 Inch NPT, NEMA 4/7, 3 PSI min, 225 max, N.O., viton

To get a quote on any Jefferson part, 
go to our Jefferson Parts Form HERE!
Flow Factor
216-765-4231
www.flowfactor.com
Jefferson Valves 1342...Jefferson Valves 1342...Jefferson Valves 1342

Sunday, February 2, 2020

Barksdale UDS7-BX ATEX Rated Pressure Switch

ATEX rated Pressure Switch from Barksdale and Flow Factor

Barksdale Series UDS7-BX Explosion Proof Rated Electronic Pressure Switch

Get a Quote on a Barksdale UDS7-BX ATEX switch HERE!

See all our pressure switches HERE!

Barksdale UDS7-BX ATEX Pressure Switch








Applications for the Barksdale UDS7-BX

  • Oil & gas pipelines
  • Refineries
  • Petrochemical plants
  • Pulp and paper mills
  • Coal and oil fired power plants
  • Cement plants
  • Gas transfers for fuel systems

Features for the Barksdale Switch UDS7-BX



    • ATEX Ex d Certified Construction
    • Dual seal protection
    • Adjustable setpoint delay - up to 9.9 seconds
    • 2 setpoints
    • High accuracy with fully adjustable deadband
    • Digital readout
    • Fully configurable via keypad
    • Suitable for rapid cycling (100 times per second)
    • NEMA 4, 7, 9 & IP66

    Barksdale UDS7-BX ATEX rated 

    Electronic Pressure Switch Part Numbers

    Barksdale UDS7-BX-08-3  0-500 PSIG (0-34.5 BAR)
    Barksdale UDS7-BX-19-3  0-600 PSIG (0-44.1 BAR)
    Barksdale UDS7-BX-10-3  0-1000 PSIG (0-69 BAR)
    Barksdale UDS7-BX-11-3  0-1500 PSIG (0-104 BAR)
    Barksdale UDS7-BX-12-3  0-2000 PSIG (0-138 BAR)
    Barksdale UDS7-BX-13-3  0-3000 PSIG (0-207 BAR)
    Barksdale UDS7-BX-14-3  0-4000 PSIG (0-276 BAR)
    Barksdale UDS7-BX-15-3  0-5000 PSIG (0-345 BAR)
    Barksdale UDS7-BX-16-3  0-6000 PSIG (0-414 BAR)
    Barksdale UDS7-BX-17-3  0-7500 PSIG (0-517 BAR)
    Barksdale UDS7-BX-18-3  0-10000 PSIG (0-689 BAR)

    Get a Quote on a Barksdale Switch UDS7-BX switch HERE!

    Flow Factor
    216-765-4231
    www.flowfactor.com

    Barksdale  Barksdale  Barksdale  Barksdale  Barksdale  Barksdale Barksdale  Barksdale 

    Friday, August 16, 2019

    Parker G7 Solenoid Valves

    Parker General Purpose G7 Series Solenoid Valves from Flow Factor
    The Evolution of Gold Ring and Skinner Valves

    For Quotes, please use our Valve Parts Form HERE!

    Benefits 
    Industry-Leading Performance 
    High Pressures 
    High Flows 
    High Temperatures 
    Corrosion Resistant 
    Environmentally Resistant 

    Specifications 

    • Port Sizes: 1/8" - 3/8" NPT 
    • Pressures: Up to 2200 psi 
    • Flows: Up to 1.06 Cv 

    Premium Construction 

    • 303 Stainless Steel 
    • Lead-Free Brass* 
    • IP67, Thermal Shock-Resistant Solenoid Coil 
    • Engineered for Long Life 
    • Proven Gold Ring™ and Skinner® Fundamentals 

    Commonly Valve Part Numbers
    2-Way-Normaly Closed-Direct Acting-AC Coils-Stainless
    20CC02GV7 
    20CC02PV7 
    20CC02QV7 
    20CC04GP7 
    20CC04GV7 
    20CC04LV7 
    20CC04PV7 
    20CC04QV7 
    20CC04TV7 
    20CC06TV7 
    20CC061V7 
    2-Way-Normaly Closed-Direct Acting-DC Coils- Stainless
    20CC02GV7 
    20CC02PV7 
    20CC02QV7 
    20CC04GV7 
    20CC04LV7 
    20CC04PV7 
    20CC04QV7 
    20CC04TV7 
    20CC06QV7 
    20CC06TV7 




















    2-Way-Normaly Closed-Direct Acting-AC Coils-Brass
    20LC02PN7 
    20LC04GN7 
    20LC04LN7 
    20LC04PN7 
    20LC04QN7 
    20LC04TN7 
    20LC041N7 
    20LC06TN7 
    20LC061N7 
    2-Way-Normaly Closed-Direct Acting-DC Coils-Brass
    20LC02PN7 
    20LC04GN7 
    20LC04LN7 
    20LC04PN7 
    20LC04QN7 
    20LC04TN7 
    20LC06QN7 
    20LC06TN7 
    Coils used on the Above Valves are:
    For AC Valves;
    C7F 120/60, with Conduit, IP67, NEMA 6
    C7G 240/60, with Conduit, IP67, NEMA 6
    C7E 24/60, with Conduit, IP67, NEMA 6
    D7F 120/60, DIN Connection, IP65, NEMA 4X
    D7G 240/60, DIN Connection, IP65, NEMA 4X
    D7E 24/60, DIN Connection, IP65, NEMA 4X
    B7F 120/60, 18 Inch Leads, IP67, NEMA 6
    B7G 240/60, 18 Inch Leads, IP67, NEMA 6
    B7E 24/60, 18 Inch Leads, IP67, NEMA 6

    For DC Valves:
    C7A 12vdc, with Conduit, IP67, NEMA 6
    C7B 24vdc, with Conduit, IP67, NEMA 6
    D7A 12vdc, DIN Connection, IP65, NEMA 4X
    D7B 24vdc, DIN Connection, IP65, NEMA 4X
    C7A 12vdc, 18 Inch Leads, IP67, NEMA 6
    C7B 24vdc, 18 Inch Leads, IP67, NEMA 6

    For Quotes, please use our Valve Parts Form HERE!



    Flow Factor
    216-765-4231
    www.flowfactor.com

    Parker General Purpose G7 Series Solenoid Valves

    Sunday, August 11, 2019

    Picking a Valve - TOMS PAVE

    Picking a Solenoid Valve using TOMS PAVE from Flow Factor

    An easy way to help pick out a valve is an acronym TOMSPAVE.

    Use the Flow Factor Valve Parts form for a quote.  Click HERE!

    T = Type of valve
    2-way, 3-way, 4-way

    O = Operation
    Normally Closed, Normally Open, Diverting, Universal

    M = Media
    Water, Oil, Gas, Steam, Other

    S = Size
    1/8, 1/4, 1/2, 3/4, 1, 1.5, 2, 3 Inch NPT

    P = Pressure
    PSI required in your application

    A = Ambient Situation
    Wet, Hazardous, Temperature, Indoor, Outdoor

    V= Voltage
    24/60, 120/60, 240/60, 480/60, 12vdc, 24vdc, 120vdc, Other

    E = Extras
    Mounting Bracket, Timer, Spade Tabs, DIN coil, Screw Terminals

    Use the Flow Factor Valve Design Form to help pick your valve.

    Use the Flow Factor Valve Parts Form for a quote.


    Flow Factor
    216-765-4231
    www.flowfactor.com

    Tuesday, June 4, 2019

    Aircraft Fire Trainer with co-ax valves

    Flow Factor and  co-ax® valves application


    Get a quote for co-ax®
     HERE!

    Aircraft Fire Trainer

    Aircraft Fire Trainer are designed to recreate a series of different emergency scenarios, including interior and exterior incident fires and large-scale fuel spill fires on airplanes, all managed by an adjacent control tower and PC control station. Inside, a series of fires can be accessed by a series of doors on multiple levels, helping to develop realistic rescue scenarios.
    Aircraft Fire Trainers are fully programmable, and automatically respond to the application of extinguishing media, for a realistic fire response.
    Fire simulations utilize clean burning propane. Alternately, "dual-fueled" fire simulations are available that burn either kerosene for maximum realism or propane for environmental compliance.






    Summary
    co-ax® valves are used to release propane or liquid fuel to the plane mock-up shown in the picture. The fuel is ignited and the fire is extinguished by fire fighting trainees. They use water to extinguish the flames. Water also keeps the mock-up from distorting. The co-ax® valves are submerged under the gravel and water in the bottom of the pool.

    Why are co-ax® valves the preferred choice?

    • Positive shut-off.
    • Fast open/closing speed  < 100 milliseconds required.
    • Compact size.
    • Valves (externally controlled) can be buried in a pit.

    Typical co-ax® valves being used in this application

    • VMK 20 NC
    • VFK 25 NC
    • MK 10 NC 1E

    Get a quote for co-ax®
     HERE!

    Flow Factor
    216-765-4231
    www.flowfactor.com

    CO-AX VALVES INC. IS PART OF THE MÜLLER CO-AX GROUP

    Sunday, June 2, 2019

    co-ax® valves for polyol applications

    co-ax® valves from Flow Factor

    Get a quote for co-ax HERE!

    co-ax® valves for polyol applications


    co-ax® valves being used in this application

    • PCS-1 10, PCS-1 15, PCS-2 10, PCS-2 15, PCS-3 15, PCB-1 10, PCD-1 10 - cartridge valves, externally controlled KB 15 direct acting valves
    • VMK-H 15, VMK-H 15 DR, VMK-H 20, VMK-H 25, VSV-M 50


    co-ax® valves are used to inject polyol, which then blends together with isocyanates to create a chemical compound called polyurethanes.
    The mixture of the chemicals form molds for many different applications, which are used to create mattresses, foam insulation for refrigerators and freezers, home and automotive seats, elastomeric shoe soles, fibers (e.g. Spandex), and adhesives.
    Isocyanates, when exposed to air, tend to form crystals that generate premature wear in valves, especially those containing abrasive fillers and they are equally destructive to the seals and seat.
    Multiple co-ax® valves have been designed and sold for polyol applications. The fast actuation speeds of the co-ax® valve combined with high cycle life and virtually no maintenance are key advantages for this application.











    Why are co-ax® valves the preferred choice?

    • Fast actuation
    • Engineered for long life (high cycle life)
    • Pressure balanced design


    Get a quote for co-ax HERE!

    Flow Factor
    216-765-4231
    www.flowfactor.com

    CO-AX VALVES INC. IS PART OF THE MÜLLER CO-AX GROUP

    Saturday, March 30, 2019

    Parker Lead Free Solenoid Valves

    Lead Free Water Valves from Flow Factor
    Parker Water, Hot Water, and Steam Solenoid Valves

    For a Quote, Contact us HERE!









    Product Features:
    Parker’s Fluid Control Division (FCD) has a long history in
    manufacturing industry leading steam and hot water valves.
    FCD has expanded this offering to include Lead Free Brass
    (containing less than 0.25% lead), meeting the SDWA, Section
    1417(d) requirements for brass.
    Our valves are specifically designed to withstand harsh
    application conditions. The steam valves have an integral
    stainless steel orifice for long life and durability.

    Typical Applications:
    • Industrial Dish Washing
    • Industrial Laundry
    • Commercial Cooking
    • Steam Tables
    • Sterilizers / Autoclaves
    • Dry Cleaning
    • Steam Presses


    Product Specifications
    Mechanical
    Valve Type:
    2-Way Normally Closed
    2-Way Normally Open
    Media:
    Water, Hot Water, Steam
    Porting:
    3/8" NPT to 1" NPT
    Wetted Materials:
    Body/Cover:
    Lead Free Brass (<0 .25="" p="">
    Operator:
    300 & 400 Series SS, Copper
    Seals:
    PTFE & EPDM

    Electrical
    Voltage:
    AC: 24/60, 120/60-110/50,
    240/60-220/50
    DC: 12 & 24

    Connections:
    1/2" Conduit with leads,
    DIN 43650 Form A
    Temperature Class:
    Water & Hot Water – Class F
    Steam – Class H
    Agency Approvals:
    UL/CSA

    Performance
    Maximum Media Temp:
    Water: Up to 180°F
    Steam: Up to 353°F
    Max Operating Pressure Differential:
    Up to 275 psi
    Orifice sizes:
    1/2" to 1"
    Flow Factor (Cv):
    Up to 12.2

    Parker Lead Free Hot Water Valve Part Numbers
    06F25CL332ACF, 08F25CL332ACF, 12F25CL348ACF, 16F25CL364ACF, 08F25CL332ACF4C05, 12F25CL348ACF4C05, 16F25CL364ACF4C05, 06F25CL332A3F, 08F25CL332A3F, 12F25CL348A3F, 16F25CL364A3F, 06F25OL332ACF, 08F25OL332ACF, 12F25OL348ACF, 16F25OL364ACF, 06F25OL332A3F, 08F25OL332A3F, 12F25OL348A3F, 16F25OL364A3F


    Parker Lead Free Steam Valve Part Numbers
    06FS5CL432ACH, 08FS5CL432ACH, 12FS5CL448ACH, 16FS5CL464ACH, 08FS5CL432ACH4C05, 12FS5CL448ACH4C05, 16FS5CL464ACH4C05

    For a Quote, Contact us HERE!

    Flow Factor
    216-765-4231

    Parker Lead Free Hot Water and Steam Valves for Industry.

    Thursday, January 24, 2019

    Solenoid Valve Trouble Shooting Guide

    Marvin the Maintenance Man wants to help you troubled shoot Solenoid Valves.

    BUY valves HERE!  Contact Flow Factor HERE!


    Whoops: "Throw the extra parts away."  All parts must be assembled correctly for the valve to operate properly.

    Whoops: "I only hit the valve ONCE with my hammer." A hammer is not a trouble shooting tool. Valve abuse contributes to the most reported problems.

    Whoops:  "We don't need a special wrench; I'll find something to take the valve apart". Special tools for the valve disassembly may be needed.  Pipe wrenches etc. will damage parts.

    Whoops: "I'll add more teflon tape."  Gobs of tape will block internal passages and interfere with seating. (These are not ball valves).

    Whoops:  I forgot to turn on the electricity." "I forgot to open the hand valve." "A strainer takes up too much room." Beware of Marvin Maintenance.

    Whoops:  "It's only 10 PSI more than maximum operating pressure."  "It's almost at the minimum operating pressure." " Voltage is not that important." Name Plate Data Applies.

    Whoops: "I throw them away." Installation and maintenance instruction sheets have trouble shooting hints, maintenance notes and assembly instructions; etc." Do Not Throw Them Away.

    Whoops: "So I piped it up backwards and/or upside down." Proper Mounting is IMPORTANT.

    Whoops: "We're out of 1 inch pipe, so I used 1/4 inch pipe." Valves, especially 3-way and 4-way valves,  should not be restricted.

    Whoops: "Well it operated pretty well for the past 20 years."  A maintenance program is suggested.

    Whoops: "The Valve is defective."  "The Valve does not operate." "The Valve Failed."  Not very descriptive. Find out part number and get application data.

    Whoops:  "I need the silver thing." = Solenoid Sub Base Assembly.
                    "I need an orifice." = Not a spare part. Buy a new valve.
                    "I need  gasket." =  Specify which one.
                    "I need  plunger." = Core Assembly.
                    "I need a solenoid." = Coil

    Whoops:  "What is a Kit?" Do not replace individual parts.  Use a kit to replace all the wearable parts and restore the valve.  Call for kit # or look on name plate.

    Whoops: "Buy any two way valve, they're are all the same." Misapplication problems can be avoided.

    Whoops: "I can trouble shoot anything!"  We believe you Marvin.

    BUY valves HERE!

    TROUBLE SHOOTING 2 WAY VALVES

    Trouble shooting 2-way DIRECT ACTING Solenoid Valves
    Normally Closed Valve Fails to OPEN when energized:
    1. No Voltage
    2. Low Voltage
    3. Burned Out Coil
    4. Excessive Pressure
    5. Binding Core
    6. Swollen or cut resilient disc
    7. No Pressure to valve

    Trouble shooting 2-way DIRECT ACTING Solenoid Valves
    Normally Closed Valve Fails to CLOSE when energized:
    1. Faulty control circuit
    2. Improper Installation
    3. Scale of foreign matter
    4. Damaged Seat or Disc
    5. Binding Core
    6. Damaged or Missing Spring

    Trouble shooting 2-way DIRECT ACTING Solenoid Valves
    Excessive Solenoid NOISE when energized:
    1. Low Voltage
    2. Loose Solenoid Parts
    3. Foreign Matter on core or Plug Nut
    4. Worn Core or plug nut
    5. Incorrect or damaged spring


    Trouble shooting 2-way PILOT OPERATED Solenoid Valves
    Normally Closed Valve Fails to Open when energized:
    1. No Voltage
    2. Low Voltage
    3. Burned Out Coil
    4. Excessive Pressure
    5. Binding Core
    6. Swollen or cut resilient disc
    7. No Pressure to valve
    8. Low Pressure
    9. Ruptured diaphragm or damaged piston ring
    10. Plugged or restricted pilot orifices



    Installation Tips for 3 and 4 way Pilot Operated Valves

    1. Do Not Select Oversized Valves. Size Carefully for Flow and Cylinder speed. For Economy and reliable operation.

    2. Use Full Area Lines in Pressure and Exhaust.

    3. I.D. (Internal Diameter) of lines and fittings must be larger than orifice.

    4. Differential Between Pressure and Exhaust must exceed the minimum at all times.

    5. Do Not Meter Flow in Pressure or Exhaust Lines.

    6. Install Speed Control Valves in the Cylinder Lines Only.

    7. Avoid Pressure Regulators if Possible. If essential, the regulator must have flow capacity to maintain the MINIMUM Differential at all times.

    8. Hydraulic Pumps or Air Reservoirs must have adequate capacity to maintain the minimum DeltaP at all times.

    9. Pressure Differential may be measured by means of gages installed immediately at the pressure and exhaust connections.

    10. Do Not Mistake a Faulty Cylinder for a valve malfunction, Isolate the Cylinder.

    BUY valves HERE!

    Get a solenoid Valve Quotation HERE!

    Flow Factor
    216-765-4231
    www.flowfactor.com

    ASCO Solenoid Valves - Parker Solenoid Valves - Jefferson Valves

    Sunday, November 25, 2018

    Barksdale Explosion Proof Temperature Switches

    Flow Factor Sells Hazardous Rated Barksdale Switches


    Buy Barksdale Explosion Proof Switches HERE!

    Applications
    Oil & gas
    Heat tracing
    Printing machinery
    Compressors
    Process equipment

    Machine tools and industrial equipment


    Click HERE for the Barksdale Catalog Page for L1X, T1X and T2X Switches

    Barksdale's L1X, T1X & T2X Series Temperature Switches provide unmatched performance, quality & reliability in a mechanical thermostat - a safe solution for hazardous locations. The Barksdale single set point L1X & T1X and  the Barksdale dual set point T2X, can switch, measure & control temperatures from 50° to 650°F (-45° to 343°C), and meets Class 1, Div. 1 & 2 hazardous location requirements. The optional adjustable differential provides precise control. These Barksdale switches can be mounted locally for control directly at the source or remotely up to 25 feet. The Barksdale L1X, T1X & T2X Series are electrically rated for 10 amps @ 125/250 VAC & 3 amps @ 480 VAC. Standard 3 & 6 pin terminal strips simplify installation. The Barksdale L1X, T1X & T2X Series are rated NEMA 4, 7 & 9 and incorporate stainless steel temperature sensors to handle a wide range of media. Optional thermowells allow the sensor to work in pressurized vessels to 5000 psi. The Barksdale L1X, T1X & T2X Series are UL listed & CSA approved & ATEX Certified for hazardous zones within the European Community.

    Barksdale T1X, L1X, T2X Explosion-Proff Temperature Switches

    Features

    Explosion-Proof For Hazardous LocationsHigh Accuracy
    Remote, local or Ambient Sensing
    UL, CSA and ATEX approved
    NEMA 4, 7 and 9 and IP66

    Technical Specifications

    Accuracy: ±1% of mid-60% of full range. At constant ambient +/- 0.5% of full scale. (Knob indication is reference only)

    Switch: One (1) single pole double throw (SPDT) circuit.
                   Two (2) independent single pole double throw (SPDT) circuits.

    Electrical: All models incorporate Underwriters?? Laboratories, Inc. and CSA listed single pole double throw snap-action switching elements.         Switches may be wired normally open or normally closed.

    Wetted Parts: 304 stainless steel

    Electrical Connection:Single: 3-pin terminal strip 
                                                 Dual: 6-pin terminal strip

    Enclosure/Housing: Designed for hazardous locations: Class I, Division 1 & 2 
    NEMA 4, 7, 9 & IP65 tamper-proof external adjustment, enclosed terminal strip.

    Local Mount: Immersion length 2-1/16 inches

    Bulb & Capillary: 6 and 12 foot length standard.

    Temperature Range: -50 to 650º F.

    Adjustment: Tamper resistant external adjustment. Turn knob clockwise to increase setpoint. (Knob indication is reference only)

    Standard Options: Thermowels, split nuts and union connections.

    Weight: Single - approximate 3.0 lbs. Dual - approximate 7.0 lbs. 
                     Dual - approximate 7.0 lbs.

    Approvals: Underwriters’ Laboratories, Inc. and Canadian Standard Assoc. are listed under Temperature indicating and regulating equipment, for use in hazardous locations, Class I, Groups B, C and D; Class II, Groups E, F and G. 

    File No. E58658, Guide No. XBDV 
    File No. LR34556, 
    Guide 400-E-O.8. Class 4868. 
    EX models are ATEX marked as follows:
    CE 0081, ISSeP 08 ATEX024X
    Ex II 2G D, Ex db IIC T6 Gb
    Ex tb IIIC T80°C Db IP66
    -40°C ≤ Tamb ≤ +75°C


    Barksdale L1X Dual Switch Hazardous Area Temperature Switches








    Barksdale T1X Dual Switch Hazardous Area Temperature Switches









    Barksdale T2X Dual Switch Hazardous Area Temperature Switches









    Flow Factor
    216-765-4231

    Barksdale Explosion-Proof Mechanical Temperature Switches