Penberthy Jet Pump Applications


Flow Factor Sells Penberthy Jet Pumps / Eductors

Terms
  • Motive - the fluid used to "power" the eductor
  • Suction - the secondary fluid being educted
  • Discharge - the combined motive/suction fluid stream exiting the eductor
LL Jet - Liquid motive / Low Head
LM Jet - Liquid Motive / Medium Head 
LH Jet - Liquid Motive / High Head
GL Jet - Gas Motive / Low Head
GH Jet - Gas Motive / High Head
ELL Jet - Heating Liquids
CTE Jet - In Tank mixing and heating eductor



Below are listed some of the problems encountered by our users in different industries and the solutions that were used to solve these problems. These industries include:
Water/Waste Water TreatmentMarina
AutomotiveFood Processing
EnvironmentalWater Collection Pits
RailwayMixing/Blending
Barge TerminalTank Heating
BreweryTransporting Solids
Corn ProcessingHeating Systems

Water/Waste Water Treatment:
Problem A water treatment plant wanted to entrain activated carbon as a filtering media to treat and regenerate application material to meet EPA regulations prior to disposing in a sewer.
Solution A Penberthy Model ELL was used to hydraulically transport the carbon media. Model LM could also have been used
Problem A treatment facility needed to pump and mix a variety of chemicals in a water stream to control pH levels.
Solution Using a Penberthy L Series liquid motive jet, they were able to do this in-line

Automotive Industry:
Problem Assemblers had to hold windshields in place during assembly.
Solution Using a Penberthy G Series jet, they were able to generate a vacuum to hold the windshield while it was positioned.
Problem A tire manufacturer needed to evacuate steam from a bladder in order for the tire to be removed from the tire press.
Solution A Penberthy G Series jet was installed to evacuate the steam and speed up the production cycle.
Problem Settling of materials in electrocoat and pretreatment tanks in automotive paint lines had to be eliminated in order to improve overall paint quality.
Solution Installation of Penberthy Model TME (Tank Mixing Eductors) provided low electrical conductivity and smooth mixing flow characteristics, improving paint finishes.

Environmental Ground Water Testing:
Problem A chemist required an efficient method of extracting ground water samples for chemical analysis.
Solution Using Penberthy Series L jet pumps, samples were taken and transferred to holding tanks for evaluation and testing.

Railcar Cleaning:
Problem Railcars need an effective method of removing a variety of powdered materials.
SolutionA simple and effective method would be to use a Penberthy GST Model jet using compressed air as the motive

Barge Terminals/Barge Cleaning:
Problem Barge terminal operators need a cost-effective method of removing rainwater from barges.
SolutionPenberthy Model L Series jet pumps are used to hydraulically pump the water from the barge. This water is transported into another barge for testing and treatment before being discharged back into the river.

Breweries:
Problem A brewery needed to heat liquids as part of the pasteurization process.
SolutionUsing a Penberthy Model SRH, the liquid was heated and pasteurized in-line. In this application, processing was improved by 30%.

Corn Processing Plants:
Problem A corn processing plant needed an inexpensive and efficient method or removing carbon dust from the bottom of their furnaces.
SolutionThey attached a perforated pipe to the suction inlet of a Penberthy Model LM jet, and using water as the motive, a vacuum was created sucking up the carbon dust.

Plastics Industries:
Problem The company needed an effective means of detecting leaks in molds.
SolutionBy using a Penberthy Model LM jet with the suction hooked up to the mold, they were able to generate a vacuum which detected leaks in the mold or seals.

Boat Docks:
Problem Boats sitting in a marina during the winter months became immobilized due to ice buildup.
SolutionUsing a Penberthy Model CTE, warmer water was brought to the surface preventing the water from freezing.

Food Processing:
Problem A processor potato chips wanted to heat water in a blancher to remove potato skins.
SolutionA Penberthy Model SRH was installed at the bottom of a tank. The water draining from the tank had sufficient head pressure to mix with the steam to allow recirculation back into the tank as well as reaching desired temperature.

Water Collection Pits:
Problem A number of businesses and homeowners needed an effective way to remove water from sump pits during flooding.
SolutionPenberthy Sump Drainer and L Series jets provided reliable methods of removing the water using no electrical power.

Mixing/Blending Applications:
Problem A storage tank manufacturer needed to move dry solids - diatomaceous earth - into a blending tank.
SolutionUsing a Penberthy Model LM with a Penberthy Washdown Hopper, they were able to mix the earth with the motive fluid and transport it into the blending tank. Once in the tank, a Penberthy Model CTE was used to provide continuous in-tank mixing.

Tank Heating:
Problem A company needed to maintain a minimum liquid temperature in their tanks, regardless of outside ambient temperatures.
Solution Using a Penberthy Model CTE as an in-tank heater in conjunction with a simple temperature control system, steam was mixed with the liquid when the outside temperature fell below a certain level.

Transporting Solids:
Problem A manufacturer of silo systems for wastewater treatment that used wetting cones with powdered activated carbon needed a means of moving the resulting slurry.
Solution By installing various Penberthy Series L liquid motive jets at the bottom of each cone, the manufacturer was able to move the slurry away using water as the motive.

Heating Systems:
Problem Condensation pits associated with underground heating systems needed to be emptied.
Solution A Penberthy model 2-R Sump Drainer was installed in each pit. This stand-alone system uses water as the motive and requires no electrical power.


Visit Flow Factor for your Penberthy Jet Pump Needs


Cv Flow Factor - Flow Coefficient for Valves

Flow Factor sells Solenoid valves, Jet Pumps and Control Valves.

The Flow Coefficient or Flow Factor is used to size and compare the flow rate through valves and other devices used for moving liquids and gases.



The flow coefficient - Cv - let us compare flow capacities of valves at different sizes, types and manufacturers. The flow coefficient is in general determined experimentally and express the flow capacity in imperial units - GPM (US gallons per minute) of water that a valve will pass for a pressure drop of 1 lb/in2 (psi).

The flow factor - Kv - is also in common use, but express the capacity in SI-units.

The flow coefficient - Cv - required for a specific application can be estimated by using specific formulas for the different fluids or gases. With the estimated Cv value - the correct valve can be selected from the manufacturers catalogues.

In more practical terms, the flow coefficient Cv is the volume (in US gallons) of water at 60°F that will flow per minute through a valve with a pressure drop of 1 psi across the valve.
The use of the flow coefficient offers a standard method of comparing valve capacities and sizing valves for specific applications that is widely accepted by industry.




Flow Coefficient - Cv - for Liquids

For liquids the flow coefficient - Cv - expresses the flow capacity in gallons per minute (GPM) of 60oF water with a pressure drop of 1 psi (lb/in2).

Flow expressed by volume

Cv = q (SG / dp)1/2         (1)
where
q = water flow (US gallons per minute)
SG = specific gravity (1 for water)
dp = pressure drop (psi)

C_v = F \sqrt{\dfrac{SG}{\Delta P}}



Flow Coefficient - Cv - for Air and other Gases

Note! - there is a difference between critical and non critical pressure drops. 

For critical pressure drop, where the outlet pressure - po - from the control valve is less than 53% of the inlet pressure - pi, the flow coefficient can be expressed as:
Cv = q [SG (T + 460)]1/2/ 660 pi         (5)
where
q = free gas per hour, standard cubic feet per hour (Cu.ft/h)
SG = specific gravity of flowing gas gas relative to air at 14.7 psia and 60oF
T = flowing air or gas temperature (oF)
pi = inlet gas absolute pressure (psia)

 For non critical pressure drop, where the outlet pressure - po - from the control valve is greater than 53% of the inlet pressure - pi, the flow coefficient can be expressed as:
Cv = q [SG (T + 460)]1/2/ [1360 (dp po)1/2]         (5b)
where
dp = (pi - po)
po = outlet gas absolute pressure (psia)

Specific Gravities of common materials and mediums

Alcohol0.82
Mercury13.95
Paraffin0.80
Petrol0.72
Water (4oC)1.00
Sea water1.02
Aluminum2.72
Brass8.48
Cadmium8.57
Chromium7.03
Copper8.79
Cast iron7.20
Lead11.35
Nickel8.73
Nylon1.12
PVC1.36
Rubber0.96
Steel7.82
Tin7.28
Zinc7.12
Acetylene0.0017
Dry air0.0013
Carbon dioxide0.00198
Carbon monoxide0.00126
Hydrogen0.00009
Nitrogen0.00125
Oxygen0.00143



www.flowfactor.com
866-360-9830

Saturday, April 14, 2012

American Meter Gas Meters In Stock


Flow Factor Stocks Elster American Meter Gas Meters

Elster American Meter is the industry’s leading supplier of diaphragm gas meters. With models to meet your applications from domestic service to large industrial uses, Elster American Meter diaphragm meters have an outstanding record for durability and reliability.

AC-250-10#TC AMCO METER, 1", ODOMETER INDEX
AC-250-5#TC
AMCO AC-250, 5# WP, TEMP. COMP

AC-630-25#TC
AMCO AC-630 METER, 25#, TC


AL-425-10# AMCO METER, 1-1/4, W/ODOMETER
AL-425-10#TC AMCO AL-425, 10#WP, TEMP. COMP

AL-425-25# AMCO METER, 1-1/4, W/ODOMETER

AL-425-25#TC AMCO AL-425, 25# WP, TEMP. COM

AM-250-5#TC

AMCO METER, TC, 5#


2M-CID-2" AMCO RPM METER WITH


2M-MTCI-2"-TWELL AMCO 2" 2M RPM W/ MERCURY TCI


3.5M-CTR-2"-TWELL AMCO 3.5M RPM WITH TWELL


3.5M-MTCI-2"-TWELL AMCO 2" 3.5M RPM W/MERCURY TCI


5.5M-CTR-2"-TWELL AMCO 5.5M RPM W/TWELL


5.5M-CTR-3"-TWELL AMCO 5.5M RPM W/TWELL


5.5M-MTCI-3"-TWELL AMCO 3" 5.5M RPM W/MERCURY TCI



Please contact us to get your Elster American Gas meter or regulator shipped today!

866-360-9830 and ask for Jerry, the AMCO METER EXPERT !
info@flowfactor.com or use our AMCO parts form

Friday, March 23, 2012

NFPA 70 E Safety (Meltric) and OSHA

NFPA 70E: THE STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE

As the foremost consensus standard for electrical safety in the workplace, NFPA 70E is the primary resource for employers to use in determining how to comply with OSHA’s electrical
safety regulations. It is also used by OSHA and the courts in the investigation of injuries in order to assess whether or not the involved employers took reasonable steps and precautions to protect their employees.

The key elements of the standard are summarized below. Complete details should be obtained from the standard itself. In Canada, CSA recently published CSA Z462 ‘Workplace Electrical Safety’ which is based on and is harmonized with NFPA 70E. Key elements in CSA Z462 are essentially the same as those found in NFPA 70E.

Article 110 – General Requirements for Electrical Safety-Related Work Practices

Training Requirements (110.6)

Employees who may be exposed to electrical hazards must be specifically trained to understand the
hazards associated with electrical energy as well as the safety-related work practices and procedures required to provide protection from them. The level of training provided determines the tasks that an employee is qualified to perform.

Only specially ‘Qualified Persons’ may perform work on or near exposed and energized electrical conductors or circuit parts. The training requirements include:

  • How to recognize the potential hazards that exist
  • How to distinguish energized from non-energized parts
  • How to determine the voltage of exposed energized electrical conductors
  • The relationship between the hazard and potential injury
  • How to avoid exposure to the hazards
  • How to select appropriate personal protective equipment
  • Specific work practices and procedures to be followed
  • Emergency procedures for assisting victims of electrical incidents
  • How to perform a hazard/risk analysis
  • How to determine approach and flash protection boundaries
Electrical Safety Program (110.7)

Employers are required to implement and document an electrical safety program to direct employee activities in a manner that is appropriate for the different voltage, energy level and circuit conditions that may be encountered. This safety program shall include all electrical safety procedures, be documented in writing, and be made available to all employees. If work on or near energized electrical conductors and circuit parts operating at 50V or more is required, the safety program must:

  • Include a procedure that defines requirements and provides guidance for workers as they perform
    work on or near live parts

  • Identify the hazard/risk evaluation procedure to be used before work is started within the limited approach boundary of energized electrical conductors and circuit parts operating at 50 volts or more.

  • Include a job briefing process to inform employees of the hazards, proper procedures, special precautions, energy source controls and PPE requirements
Working While Exposed to Electrical Hazards (110.8)

Safety work practices consistent with the nature and extent of the associated electrical hazards shall be used to safeguard employees from injury while working on or near exposed electrical or circuit parts that are or can become energized. Two primary conditions are identified and addressed:

  1. Energized Electrical Conductors and Circuit Parts – Safe Work Condition. Live parts to
    which an employee might be exposed shall be put into an electrically safe work condition before employees can work on or near them, unless work on energized components can be justified
    according to section 130.1.

  2. Energized Electrical Conductors and Circuit Parts – Unsafe Work Condition. Only qualified persons may work on electrical conductors or circuit parts that have not been put into an electrically safe work condition.

The requirements for establishing an electrically safe work condition are indicated in Article 120, while
the requirements for work involving electrical hazards are covered in Article 130.

Article 120 – Establishing an Electrically Safe Work Condition

The most effective way to prevent an electrical injury is to completely remove the source of electrical
energy and eliminate the possibility of its reappearance. To do so, workers must identify and disconnect
all possible sources of electricity.

Process of Achieving an Electrically Safe Work Condition (120.1)
  1. Identify all possible sources of electric supply.
    Care should be taken to identify the possible presence of secondary sources.

  2. Properly interrupt the load current(s) and open the disconnecting device(s).
    Not all disconnecting devices are rated to interrupt load currents; this should only be done with a properly rated device.

  3. Verify deenergization through visual inspection of the disconnect contacts.
    Disconnecting means may sometimes fail to open all phase conductors when the handle is operated,
    so it is necessary to verify physical contact separation. If this requires removing the disconnect
    door or cover, appropriate PPE must be used.

  4. Apply lockout/tagout devices.
    This should be done in accordance with a formally established company policy.

  5. Use a voltage detector to test each conductor to which the worker may be exposed in
    order to verify deenergization.

    The voltage detecting device must be functionally tested both before and after taking the measurements in order to ensure that it is working satisfactorily.

  6. Circuit parts with induced voltages or stored electrical energy must be grounded.
    If the conductors being deenergized could contact other energized conductors or circuit parts, grounding devices rated for the available fault duty should be applied.
Justification (130.1)

Deciding to work on or near energized electrical conductors and circuit parts should be a last resort in
the workplace, after all other opportunities for establishing an electrically safe work condition have been exhausted. Work on energized parts at 50V or more should only be performed if the employer can demonstrate that deenergizing will introduce additional hazards or is not feasible due to equipment
design or operational limitations.

When non-routine work must be performed on energized parts, a detailed work permit must be
prepared before the work can start. The work permit must document the following elements and be approved by a responsible manager or safety officer:

  • A description of the circuit and equipment to be worked on
  • Justification for performing the work in an energized condition
  • A description of the safe work practices to be employed
  • Results of the shock hazard analysis
  • Determination of shock protection boundaries
  • Results of the flash hazard analysis
  • The flash protection boundary
  • The personnel protective equipment required for worker safety
  • Restricted access of unqualified persons from the work area
  • Evidence that the job briefing has been completed
Approach Boundaries to Energized Electrical Conductors or Circuit Parts (130.2)

Limited, restricted and prohibited approach boundaries must be determined in order to identify safe approach distances and the precautions required to minimize the possibility of shock.

Arc Flash Hazard Analysis (130.3)

An arc flash hazard analysis shall be done in order to protect personnel from the possibility of being injured by an arc flash. As part of this analysis, flash protection boundaries must be determined based on available bolted fault currents and the incident energy exposure level for personnel working within this boundary must be calculated.

Personal and Other Protective Equipment (130.7)

Employees working in areas where electrical hazards are present shall be provided with, and shall use, protective equipment that is designed and constructed for the specific part of the body to be protected
and for the work to be performed.

Requirements for eye, hand, head and body protection and/or v-rated tools are determined based on the hazard/risk category for the work to be performed. The standard provides a reference table indicating the hazard/risk category for many of the electrical tasks performed in industry and also provides a chart showing the protective equipment that is required for each hazard/risk category.

The tables below show the hazard/risk categories for several common tasks and describe the protective equipment required for each of the categories.

Panelboards or Switchboards Rated >240V and up to 600V
CB or fused switch operation with covers on RISK level 0
CB or fused switch operation with covers off RISK level 1
Work on energized parts, including voltage testing RISK level 2*

Other 600V Class (277V through 600V, nominal) Equipment
Opening hinged covers (to expose bare, energized parts) RISK level 1
Removal of bolted covers (to expose bare, energized parts) RISK level 2*

Typical Protective Clothing Systems
Long sleeve shirt and pants plus safety glasses, hearing protection and gloves for RISK level 0
Arc-rated (level 4) long sleeve shirt, pants, coverall, face shield, jacket, leather gloves
and work shoes for RISK level 1
Arc-rated (level 8) long sleeve shirt, pants, coverall, face shield, jacket, leather gloves
and work shoes for RISK level 2
Arc-rated (level 8) suit hood, long sleeve shirt, pants, coverall, jacket, leather gloves
and work shoes for RISK level 2*