Wednesday, May 22, 2013

Parker 71315SN Series 3-way Solenoid Valves

Parker Skinner 71315 series three way Solenoid valves from Flow Factor

Three way valves are used to operate cylinders, valves and other pneumatic or hydraulic parts.  The three way valve can also be used as a diverting valve to change a fluid's direction one way or another way.  Direct acting three way valves can be ported to be Normally Closed, Normally Open or Diverting.  The most common 71315 series parker valves are listed below.  The series comes in 1/8 or 1/4 inch ports, up to 800 psi, and can have 12 vdc, 24 vdc, 12vac, 24vac, 120vac, 240vac abd 480 vac coils.

Use our valve parts form to help us send you a quote.

View our Parker Three Way valves HERE!

Parker 71315 1/8 inch valves 

71315AKDKN00
71315AKDKN00N0C111P3
71315AKDKN00N0H111C2
71315AKDKN00N0H111P3
71315AKDKN00N0HZ10C2
71315J31MN00
71315SN1EN00
71315SN1EN00N0C111B2
71315SN1EN00N0C111P3
71315SN1EN00N0C111Q3
71315SN1EN00N0L111C2
71315SN1ENJ1
71315SN1ENJ1M2G011C1
71315SN1ENJ1N0C111B2
71315SN1ENJ1N0C111C1
71315SN1ENJ1N0C111C2
71315SN1ENJ1N0C111C6
71315SN1ENJ1N0C111P0
71315SN1ENJ1N0C111P3
71315SN1ENJ1N0C111Q3
71315SN1ENJ1N0H111C2
71315SN1ENJ1N0H111C6
71315SN1ENJ1N0L111C1
71315SN1ENJ1N0L111C2
71315SN1ENJ1N0L111P3
71315SN1ENM5N0C222C2
71315SN1ENM5N0L111P3
71315SN1EV00
71315SN1EV00N0C111C2
71315SN1EV00N0C111P3
71315SN1EV00N0C111Q3
71315SN1EVJ1
71315SN1EVJ1M2J011C2
71315SN1EVJ1N0C111P3
71315SN1EVJ1N0H111P3
71315SN1GN00
71315SN1GN00N0C111B2
71315SN1GN00N0C111C1
71315SN1GN00N0C111C2
71315SN1GN00N0C111P3
71315SN1GN00N0C111Q3
71315SN1GN00N0D100P3
71315SN1GN00N0H111C2
71315SN1GN00N0H111P3
71315SN1GN00N0L111C1
71315SN1GN00N0L111C2
71315SN1GN00N0L111P3
71315SN1GNJ1
71315SN1GNJ1N0C111B2
71315SN1GNJ1N0C111C1
71315SN1GNJ1N0C111C2
71315SN1GNJ1N0C111P3
71315SN1GNJ1N0C111Q8
71315SN1GNJ1N0H111C1
71315SN1GNJ1N0H111C2
71315SN1GNJ1N0H111P3
71315SN1GNJ1N0L111B2
71315SN1GNJ1N0L111C1
71315SN1GNJ1N0L111C2
71315SN1GNJ1N0L111P3
71315SN1GNM5
71315SN1GNM5N0C111C2
71315SN1GNM5N0C111P3
71315SN1GNM5N0L111P3
71315SN1GV00
71315SN1GV00N0C111P3
71315SN1GV00N0C111Q3
71315SN1GV00N0C222C1
71315SN1GV00N0D500C2
71315SN1GV00N0H111C2
71315SN1GVJ1
71315SN1GVJ1N0C111C2
71315SN1GVJ1N0C111P3
71315SN1GVJ1N0C111Q3
71315SN1GVJ1N0H111P3
71315SN1GVJ1N0H222C2
71315SN1GVJ1N0L111C2
71315SN1GVJ1N0L111P3
71315SN1GVM5N0L111P3
71315SN1KN00
71315SN1KN00N0C111C1
71315SN1KN00N0C111P3
71315SN1KN00N0C111Q3
71315SN1KN00N0H111P3
71315SN1KNJ1
71315SN1KNJ1N0C111B2
71315SN1KNJ1N0C111C1
71315SN1KNJ1N0C111C2
71315SN1KNJ1N0C111P3
71315SN1KNJ1N0C111Q3
71315SN1KNJ1N0C222C1
71315SN1KNJ1N0C222C2
71315SN1KNJ1N0H111C2
71315SN1KNJ1N0H111P3
71315SN1KNJ1N0H111Q3
71315SN1KNJ1N0HZ10Q3
71315SN1KNJ1N0L111B2
71315SN1KNJ1N0L111C2
71315SN1KNJ1N0L111P3
71315SN1KNJ1N0L111Q3
71315SN1KV00
71315SN1KV00M1G011P3
71315SN1KV00N0C111P3
71315SN1KV00N0H111C2
71315SN1KVJ1N0C111C2
71315SN1KVJ1N0C111P3
71315SN1KVJ1N0L111B2
71315SN1KVJ1N0L111C2
71315SN1KVK0N0L111P3
71315SN1KVM5
71315SN1KVM5N0C111P3
71315SN1KVM5N0L111P3
71315SN1MN00
71315SN1MN00N0C111P3
71315SN1MN00N0C111Q3
71315SN1MN00N0H111C2
71315SN1MN00N0H111P3
71315SN1MN00N0L111C2
71315SN1MN00N0L111P3
71315SN1MNJ1
71315SN1MNJ1N0C111B2
71315SN1MNJ1N0C111C2
71315SN1MNJ1N0C111P3
71315SN1MNJ1N0H111C6
71315SN1MNJ1N0H111P3
71315SN1MNJ1N0L111C1
71315SN1MNJ1N0L111P3
71315SN1MNM5N0C111P3
71315SN1MTJ1
71315SN1MTJ1N0C111P3
71315SN1MTJ1N0L111C2
71315SN1MV00
71315SN1MV00M1G011P3
71315SN1MV00N0C111C2
71315SN1MV00N0C111P3
71315SN1MVJ1
71315SN1MVJ1N0C111C2
71315SN1MVJ1N0C111P3
71315SN1MVJ1N0C222P3
71315SN1SNJ1
71315SN1SNJ1N0C111B2
71315SN1SNJ1N0C111C2
71315SN1SNJ1N0C111P3
71315SN1SV00N0L111C1
71315SN1SVJ2N0C111C2
71315SN1VN00N0C111P3
71315SN1VNJ1
71315SN1VNJ1N0C111P3

Parker 71315 1/4 inch valves
71315SN2EN00
71315SN2EN00M1J011C1
71315SN2EN00M2G011C2
71315SN2EN00N0C111B2
71315SN2EN00N0C111C1
71315SN2EN00N0C111C2
71315SN2EN00N0C111P3
71315SN2EN00N0C111Q3
71315SN2EN00N0C222P3
71315SN2EN00N0H111C2
71315SN2EN00N0H111P3
71315SN2EN00N0L111C1
71315SN2EN00N0L111C2
71315SN2EN00N0L111P3
71315SN2EN00N0L222C2
71315SN2ENJ1
71315SN2ENJ1M1G011C1
71315SN2ENJ1M1G011C2
71315SN2ENJ1M1G011P3
71315SN2ENJ1M1J011C1
71315SN2ENJ1M1J011C2
71315SN2ENJ1M2J011C1
71315SN2ENJ1N0C111B2
71315SN2ENJ1N0C111C1
71315SN2ENJ1N0C111C2
71315SN2ENJ1N0C111C6
71315SN2ENJ1N0C111P3
71315SN2ENJ1N0C111Q3
71315SN2ENJ1N0H111B2
71315SN2ENJ1N0H111C1
71315SN2ENJ1N0H111C2
71315SN2ENJ1N0H111C6
71315SN2ENJ1N0H111P3
71315SN2ENJ1N0H111Q3
71315SN2ENJ1N0HZ09C2
71315SN2ENJ1N0HZ10Q3
71315SN2ENJ1N0L111C1
71315SN2ENJ1N0L111C2
71315SN2ENJ1N0L111P3
71315SN2ENM5
71315SN2ENM5N0C111C1
71315SN2ENM5N0C111C2
71315SN2ENM5N0C111C6
71315SN2ENM5N0C111P3
71315SN2ENM5N0H111C1
71315SN2ENM5N0H111C2
71315SN2ENM5N0H111P3
71315SN2ENR1
71315SN2ENR1N0H111C2
71315SN2ENR1N0H111P3
71315SN2ENR1N0HZ10C2
71315SN2ETJ1
71315SN2ETJ1N0C111P3
71315SN2EV00
71315SN2EV00M2G011C1
71315SN2EV00N0C111P3
71315SN2EV00N0L111C2
71315SN2EV00N0L111P3
71315SN2EVJ1
71315SN2EVJ1N0C111B2
71315SN2EVJ1N0C111C1
71315SN2EVJ1N0C111C2
71315SN2EVJ1N0C111C6
71315SN2EVJ1N0C111P3
71315SN2EVJ1N0C111Q3
71315SN2EVJ1N0H111C2
71315SN2EVJ1N0H111P3
71315SN2EVJ1N0H111Q3
71315SN2EVJ1N0H2223N
71315SN2EVJ1N0H222C2
71315SN2EVJ1N0H222P3
71315SN2EVJ1N0L222C1
71315SN2EZ01N0C111P3
71315SN2GEJ1
71315SN2GEJ1N0C111P3
71315SN2GEJ1N0D100C2
71315SN2GN00
71315SN2GN00N0C111C2
71315SN2GN00N0C111P3
71315SN2GN00N0C111Q3
71315SN2GN00N0D100C1
71315SN2GN00N0D100P3
71315SN2GN00N0H111B2
71315SN2GN00N0H111C2
71315SN2GN00N0H111P3
71315SN2GN00N0H111Q3
71315SN2GN00N0H222P3
71315SN2GN00N0HZ09C2
71315SN2GN00N0L111C2
71315SN2GN00N0L111P3
71315SN2GNJ1
71315SN2GNJ1M1G011P3
71315SN2GNJ1M1J011C1
71315SN2GNJ1N0C111B2
71315SN2GNJ1N0C111C1
71315SN2GNJ1N0C111C2
71315SN2GNJ1N0C111P3
71315SN2GNJ1N0C111Q3
71315SN2GNJ1N0C111Q8
71315SN2GNJ1N0C222C1
71315SN2GNJ1N0C222P3
71315SN2GNJ1N0D100C2
71315SN2GNJ1N0D100Q3
71315SN2GNJ1N0H111B2
71315SN2GNJ1N0H111C1
71315SN2GNJ1N0H111C2
71315SN2GNJ1N0H111C6
71315SN2GNJ1N0H111P3
71315SN2GNJ1N0H111Q3
71315SN2GNJ1N0H222C2
71315SN2GNJ1N0H222P3
71315SN2GNJ1N0HZ09C2
71315SN2GNJ1N0HZ09P3
71315SN2GNJ1N0HZ09Q3
71315SN2GNJ1N0L111C1
71315SN2GNJ1N0L111P3
71315SN2GNJ1N0L111Q3
71315SN2GNM5
71315SN2GNM5N0C111P3
71315SN2GNM5N0H111C2
71315SN2GNM5N0H111P3
71315SN2GNM5N0L111P3
71315SN2GNR1N0H111P3
71315SN2GTJ1
71315SN2GTJ1N0C111P3
71315SN2GV00
71315SN2GV00N0C111C8
71315SN2GV00N0C111P3
71315SN2GV00N0C111Q3
71315SN2GV00N0C222P3
71315SN2GV00N0H111C2
71315SN2GVJ1
71315SN2GVJ1N0C111B2
71315SN2GVJ1N0C111C2
71315SN2GVJ1N0C111P3
71315SN2GVJ1N0D100P3
71315SN2GVJ1N0H111C1
71315SN2GVJ1N0H111C2
71315SN2GVJ1N0H111P3
71315SN2GVJ1N0H111Q3
71315SN2GVJ1N0H222P3
71315SN2GVJ1N0L111P3
71315SN2GVJ2N0D100C2
71315SN2GVM5
71315SN2GVM5N0C222C2
71315SN2GVM5N0C222P3
71315SN2GVM5N0H111P3
71315SN2GZ05N0C111P3
71315SN2GZ05N0C111Q3
71315SN2KEJ1N0D100C2
71315SN2KEJ1N0H111C2
71315SN2KEJ1N0H222P3
71315SN2KN00
71315SN2KN00N0C111C2
71315SN2KN00N0C111P3
71315SN2KN00N0C111Q3
71315SN2KN00N0D100P3
71315SN2KN00N0H111B2
71315SN2KN00N0H111C2
71315SN2KN00N0H111P3
71315SN2KN00N0H111Q3
71315SN2KN00N0L111C1
71315SN2KN00N0L111C2
71315SN2KN00N0L111P3
71315SN2KNJ1
71315SN2KNJ1M1G011P3
71315SN2KNJ1N0C111B2
71315SN2KNJ1N0C111C1
71315SN2KNJ1N0C111C2
71315SN2KNJ1N0C111C6
71315SN2KNJ1N0C111P3
71315SN2KNJ1N0C111Q3
71315SN2KNJ1N0C111Q8
71315SN2KNJ1N0D100C1
71315SN2KNJ1N0D100C2
71315SN2KNJ1N0D100P3
71315SN2KNJ1N0D100Q3
71315SN2KNJ1N0H111C1
71315SN2KNJ1N0H111C2
71315SN2KNJ1N0H111P3
71315SN2KNJ1N0H111Q3
71315SN2KNJ1N0L111C1
71315SN2KNJ1N0L111P3
71315SN2KNM0
71315SN2KNM0N0L111P3
71315SN2KNM5
71315SN2KNM5M1J011C1
71315SN2KNM5N0C111B2
71315SN2KNM5N0C111C1
71315SN2KNM5N0C111C2
71315SN2KNM5N0C111P3
71315SN2KNM5N0H111C2
71315SN2KNM5N0H111P3
71315SN2KTJ1
71315SN2KV00
71315SN2KV00N0C111P3
71315SN2KV00N0H111P3
71315SN2KV00N0L111P3
71315SN2KVJ1
71315SN2KVJ1N0C111B2
71315SN2KVJ1N0C111C2
71315SN2KVJ1N0C111P3
71315SN2KVJ1N0C222C2
71315SN2KVJ1N0H111C1
71315SN2KVJ1N0H111C2
71315SN2KVJ1N0H111C6
71315SN2KVJ1N0H111P3
71315SN2KVJ1N0L222C1
71315SN2KVJ2
71315SN2KVJ2N0H111P3
71315SN2KVM5N0H111C2
71315SN2KVM5N0L111P3
71315SN2ME00N0D100C2
71315SN2ME00N0D100P3
71315SN2MEJ1
71315SN2MEJ1N0H111P3
71315SN2MEJ1N0L111P3
71315SN2MN00
71315SN2MN00N0C111C1
71315SN2MN00N0C111C2
71315SN2MN00N0C111P3
71315SN2MN00N0C222P3
71315SN2MN00N0D100C2
71315SN2MN00N0H111P3
71315SN2MN00N0H111Q3
71315SN2MN00N0L111C1
71315SN2MN00N0L111P3
71315SN2MN00N0L111Q3
71315SN2MNJ1
71315SN2MNJ1N0C111B2
71315SN2MNJ1N0C111C1
71315SN2MNJ1N0C111C2
71315SN2MNJ1N0C111C6
71315SN2MNJ1N0C111P3
71315SN2MNJ1N0C111Q3
71315SN2MNJ1N0D100P3
71315SN2MNJ1N0H111C1
71315SN2MNJ1N0H111C2
71315SN2MNJ1N0H111C6
71315SN2MNJ1N0H111P3
71315SN2MNJ1N0H111Q3
71315SN2MNJ1N0L111C2
71315SN2MNJ1N0L111P3
71315SN2MNM5
71315SN2MNM5M1J011C1
71315SN2MNM5N0C111C1
71315SN2MNM5N0C111C6
71315SN2MNM5N0H111C1
71315SN2MNM5N0H111C2
71315SN2MNM5N0H111P3
71315SN2MTJ1
71315SN2MTJ1N0C111C2
71315SN2MTJ1N0C111P3
71315SN2MTJ1N0LZ01P3
71315SN2MV00
71315SN2MV00N0C111C2
71315SN2MV00N0C111P3
71315SN2MV00N0H111C2
71315SN2MV00N0H111P3
71315SN2MV00N0L111Q3
71315SN2MVJ1
71315SN2MVJ1M2G011C2
71315SN2MVJ1N0C111B2
71315SN2MVJ1N0C111C2
71315SN2MVJ1N0C111P3
71315SN2MVJ1N0H111P3
71315SN2MVJ1N0L111C2
71315SN2MVJ1N0LZ01P3
71315SN2MZ01N0L111C1
71315SN2SN00
71315SN2SN00N0C111P3
71315SN2SN00N0H111C2
71315SN2SN00N0L111C2
71315SN2SN00N0L111P3
71315SN2SNJ1
71315SN2SNJ1N0C111B2
71315SN2SNJ1N0C111C1
71315SN2SNJ1N0C111C2
71315SN2SNJ1N0C111P3
71315SN2SNJ1N0C111Q3
71315SN2SNJ1N0D100C2
71315SN2SNJ1N0D100P3
71315SN2SNJ1N0H111C2
71315SN2SNJ1N0H111P3
71315SN2SNJ1N0L111C2
71315SN2SNJ1N0L111P3
71315SN2SNJ1N0L111Q3
71315SN2SVJ1
71315SN2SVJ1N0C111C2
71315SN2SVJ1N0H111C2
71315SN2VN00
71315SN2VN00N0C111P3
71315SN2VNJ1
71315SN2VNJ1M2G011C1
71315SN2VNJ1N0C111C1
71315SN2VNJ1N0C111C2
71315SN2VNJ1N0C111P3
71315SN2VNJ1N0C111Q3
71315SN2VNJ1N0D100C1
71315SN2VNJ1N0H111C2
71315SN2VNJ1N0H111P3
71315SN2VNJ1N0L111C2
71315SN2VNJ1N0L111P3
71315SN2VNJ1N0L111Q8
71315SN2VVJ1
71315SN2VVJ1N0C222P3
71315SN2VVJ1N0D100C2
71315SN2VVJ1N0L111C2
71315SN2VVJ1N0L111Q3

Use our valve parts form to help us send a quote or call the number below.


866-360-9830

www.flowfactor.com

Wednesday, February 13, 2013

Chromalox MT-3 Heaters with Explosion Proof Housings

Flow Factor provides Screw Plug immersion Heaters with Explosion resistant housings (NEMA7).

These MT-3 series Chromalox COPPER Screw Plug Immersion heaters for clean water have a 2 ½ inch NPT(M) Brass Screw Plug and copper sheathed electric heating elements. The Watt Density is between 46 and 51 and total wattages from 3 to 18 kilowatts (KW). Voltages come in 120, 208, 240, 480 single phase and 208, 240 and 480 three phase with explosion resistant (NEMA 7 – E2 style) terminal housings.

Below are catalog parts, MT-330, MT-345, MT-360, MT-375, MT-390, MT-3120, MT-3150, MT-3180.

Wattages are, 3.3 kw, 3.45 kw, 6kw, 7.5 kw, 9kw, 12kw, 15 kw and 18 kilowatts.

All the below COPPER sheathed heaters are 240 volts or 480 volts, single or three phase.  These are the most common voltages.  For some wattages, 120 volts and 208 volts are available, click HERE for full list.

Chromalox MT-330E2, Immersion Heater, 3 kw, 240 volts, Copper Elements, NEMA 7 Enclosure  pcn 288809

Chromalox MT-330E2, Immersion Heater, 3 kw, 240 volts/3 phase, Copper Elements, NEMA 7 Enclosure pcn 288817

Chromalox MT-330E2, Immersion Heater, 3 kw, 480 volts, Copper Elements, NEMA 7 Enclosure  pcn 310818

Chromalox MT-330E2, Immersion Heater, 3 kw, 480 volts/3 phase, Copper Elements, NEMA 7 Enclosure  pcn  322288
Chromalox MT-337E2, Immersion Heater, 3.75 kw, 240 volts, Copper Elements, NEMA 7 Enclosure  pcn  288825

Chromalox MT-337E2, Immersion Heater, 3.75 kw, 240 volts/3 phase, Copper Elements, NEMA 7 Enclosure  pcn  288833

Chromalox MT-337E2, Immersion Heater, 3.75 kw, 480 volts, Copper Elements, NEMA 7 Enclosure  pcn  310834


Chromalox MT-337E2, Immersion Heater, 3.75 kw, 480 volts/3 phase, Copper Elements, NEMA 7 Enclosure  pcn  322333

Chromalox MT-345E2, Immersion Heater, 4.5 kw, 240 volts, Copper Elements, NEMA 7 Enclosure  pcn  288841

Chromalox MT-345E2, Immersion Heater, 4.5 kw, 240 volts/3 phase, Copper Elements, NEMA 7 Enclosure  pcn  288850

Chromalox MT-345E2, Immersion Heater, 4.5 kw, 480 volts, Copper Elements, NEMA 7 Terminal Enclosure  pcn  288868

Chromalox MT-345E2, Immersion Heater, 4.5 kw, 480 volts/3 phase, Copper Elements, NEMA 7 Terminal Enclosure  pcn  288876

Chromalox MT-360E2, Immersion Heater, 6 kw, 240 volts, Copper Elements, NEMA 7 Terminal Enclosure  pcn 288884

Chromalox MT-360E2, Immersion Heater, 6 kw, 240 volts/3 phase, Copper Elements, NEMA 7 Terminal Enclosure  pcn 288892

Chromalox MT-360E2, Immersion Heater, 6 kw, 480 volts, Copper Elements, NEMA 7 Enclosure pcn 288905

Chromalox MT-360E2, Immersion Heater, 6 kw, 480 volts/3 phase, Copper Elements, NEMA 7 Enclosure  pcn  288913

Chromalox MT-375E2, Immersion Heater, 7.5 kw, 240 volts, Copper Elements, NEMA 7 Terminal Enclosure  pcn  288921

Chromalox MT-375E2, Immersion Heater, 7.5 kw, 240 volts/3 phase, Copper Elements, NEMA 7 Enclosure  pcn  288930

Chromalox MT-375E2, Immersion Heater, 7.5 kw, 480 volts, Copper Elements, NEMA 7 Terminal Enclosure  pcn  288948

Chromalox MT-375E2, Immersion Heater, 7.5 kw, 480 volts/3 phase, Copper Elements, NEMA 7 Enclosure  pcn 288956

Chromalox MT-390E2, Immersion Heater, 9 kw, 240 volts, Copper Elements, NEMA 7 Enclosure  pcn  288964

Chromalox MT-390E2, Immersion Heater, 9 kw, 240 volts/3 phase, Copper Elements, NEMA 7 Terminal Enclosure  pcn  288972

Chromalox MT-390E2, Immersion Heater, 9 kw, 480 volts, Copper Elements, NEMA 7 Terminal Enclosure  pcn  288980

Chromalox MT-390E2, Immersion Heater, 9 kw, 480 volts/3 phase, Copper Elements, NEMA 7 Enclosure  pcn  288999



Chromalox MT-3120E2, Immersion Heater, 12 kw, 240 volts, Copper Elements, NEMA 7 Encl.  pcn  322552

Chromalox MT-3120E2, Immersion Heater, 12 kw, 240 volts/3 phase, Copper Elements, NEMA 7 Terminal Encl.  pcn  322579

Chromalox MT-3120E2, Immersion Heater, 12 kw, 480 volts, Copper Elements, NEMA 7 Term. Encl. :  product code number (pcn) 322595


Chromalox MT-3120E2, Immersion Heater, 12 kw, 480 volts/3 phase, Copper Elements, NEMA 7 Term. Enclosure :  product code is 322616

Chromalox MT-3150E2, Immersion Heater, 15 kw, 240 volts, Copper Elements, NEMA 7 Explosion Proof Terminal Enclosure  pcn  322675


Chromalox MT-3150E2, Immersion Heater, 15 kw, 240 volts/3 phase, Copper Elements, NEMA 7 Encl.  pcn  322691

Chromalox MT-3150E2, Immersion Heater, 15 kw, 480 volts, Copper Elements, NEMA 7 Explosion Resistant Terminal Enclosure : pcn  322712

Chromalox MT-3150E2, Immersion Heater, 15 kw, 480 volts/3 phase, Copper Elements, NEMA 7 Terminal Enclosure  pcn  322739

Chromalox MT-3180E2, Immersion Heater, 18 kw, 240 volts, Copper Elements, NEMA 7 Terminal Enclosure  pcn  322771


Chromalox MT-3180E2, Immersion Heater, 18 kw, 240 volts/3 phase, Copper Elements, NEMA 7 Terminal Enclosure  pcn  322798

Chromalox MT-3180E2, Immersion Heater, 18 kw, 480 volts, Copper Elements, NEMA 7 Terminal Enclosure  pcn  322819

Chromalox MT-3180E2, Immersion Heater, 18 kw, 480 volts/3 phase, Copper Elements, NEMA 7 Terminal Enclosure  pcn  322835



For similar heaters with STAINLESS Steel Element, please click Here.
For INCOLOY Element Immersion Heaters, Please click HERE.

Please note that the heaters will require contactors, solid state relays or SCR controls for the power switching.
These are sized in amps.  We can help with the sizing of the heaters.

Please call Flow Factor at 216-765-4231 or contact us by email HERE.
www.flowfactor.com

Monday, February 11, 2013

ERDCO Flow Meters

Indicating and measuring Flow with ERDCO Flow Meters is a simple Process at Flow Factor.

Flow measurement solutions for liquid, gas or steam service in 1/2" to 72" pipe sizes.


ERDCO® offers a complete line of flowmeters, sight flow indicators, flow transmitters and flow indicating switches. We employ elegantly simple measuring technologies with proven reliability in utility fluid applications.
Whether it's chilled water, air, nitrogen, steam, lube oil or other process support fluid, ERDCO has the flow measurement solution. Select from in-line and insertion styles that feature simplicity, rugged construction and reliable operation. This product range has great versatility across a broad set of applications.

3100 See-Flo® Indicator

See-Flo® indicators show you at a glance, the color, clarity and flow of liquids in process lines. An alloy vane indicator is flexed in proportion to flow through the variable area indicator housing. The large tempered glass window permits easy observation of fluid conditions and vane indicator position for a wide range of liquids in vertical or horizontal piping runs.
The wedge shape of the indicator housing makes the See-Flo® practically self-cleaning. Where periodic maintenance might be necessary, the window is easily removed and replaced. As it is intended to be used as a flow indicator, the scale is not calibrated in this model.
A special write-on surface is provided along the sweep of the indicator on which system reference points may be marked. This can help you establish normal operating limits, rate efficiency or balance a process system.

3200 See-Flo® Indicator




See-Flo® meters indicate flow rate and permit visual inspection of water, air or other transparent fluids. For general purpose industrial service, See-Flo® meters handle a wide range of process fluids in vertical or horizontal piping runs.
The wedge shape of the meter housing makes See-Flo® practically self-cleaning. Where periodic maintenance might be necessary, the tempered glass window is easily removed and replaced. Because of its large internal cavities this product will not plug up like the old glass tube "rotameters".
Each flowmeter is calibrated to be direct reading for the liquid or gas operating conditions that you specify. Scales with special engineering units and dual units of measure are available.

3400 Armor-Flotm meters

Measure liquid, gas or steam flow rates in horizontal or vertical pipelines. Armor-Flotm meters handle more aggressive fluids that cannot be measured with See-Flo® due to clarity, pressure or where process also requires limit switches or signal transmission.
Rare earth cobalt magnets are used to couple the flow isolated indicator with the vane. There are no shaft connections or stuffing boxes. The internal wedge shape of the Armor-Flotm housing is designed for self-cleaning. These features emphasize simplicity and reduce maintenance.
Each flowmeter is calibrated to be direct reading for a liquid or gas at it's operating conditions. The large indicator and dial are easy to read. Scales with special engineering units and dual units of measure are available.

3500 Armor-Flotm meter with Limit Switch


In addition to the performance benefits of the 3400 Series flow rate meter, the 3500 Series Armor-Flotm includes switching capabilities. Adjustable flow switches provide positive indication of flow/no flow conditions or may be positioned to establish process limits. In either application the switch captures the indicator preventing movement until the flow rate is within the acceptable range.
The glass encapsulated reed switches are SPDT rated at 0.25 amperes at 120vac (1.5 amperes at 24vdc). This switch is appropriate for use in Class I, Division 2 areas.


3600 Armor-Flotm meter with Signal Output

Here is a combination of signal transmission with independent mechanical local flow rate indication. Should your 24vdc loop go down, you will still be able to take flow rate readings at the meter.
The output signal is linear within the middle 80% of the range and well suited for tracking utility applications. A response curve is furnished with each flowmeter. Transmitter signal options include:
  • 4-20 mA two wire loop powered
  • 4-20 mA with concurrent 0-1000Hz frequency output
  • 4-20 mA with two adjustable set points
Applications include valve modulation, remote metering, sub-metering, blending and totalizing. Use with ERDCO accessory displays for remote indication or totalizing.

3700 Armor-Flotm meter w/ NEMA-7 Enclosure

Transmit a signal or actuate limit switches in hazardous areas with the 3700 Series Armor-Flotm meter. The cover housing is listed by Underwriters Laboratories as an enclosure for metering equipment in hazardous areas. It contains an easy to read calibrated scale and the signal output or switch circuitry. These devices are magnetically coupled with the flow sensor. This results in complete isolation from the fluid stream.
Six signal and switch options are available:
  • 4-20 mA two wire transmitter
  • 4-20 mA transmitter and frequency output
  • 4-20 mA transmitter with 2 adjustable setpoints
  • Low flow limit switch
  • High flow limit switch
  • Low and high flow limit switches
All instruments are calibrated to the liquid or gas flow conditions that you specify. A wide range of connection types, engineering units, signal options and sizes are available.

20 Series Turbo-Flotm Probe



Here is the precision of a turbine meter with insertion meter ease of use. The low mass non-metallic turbine rotates in direct proportion to fluid velocity and can provide local flow rate and total information with no external power required. 4-20 mA signal outputs are also available for control and automation functions.
The Series 20 probe features 304 stainless steel probe and fitting construction with insertion length for 1.5 to 72 inch pipe sizes. This product is typically installed through 1.25/1.5 inch pipe tees, saddles or threaded spuds - all standard pipe fittings. Very popular method of installation is through a 1.5 inch port ball valve which provides for easy installation and removal.
A full compliment of instrumentation for indication of flow rate, totalization and control function is available. Make Turbo-Flotm your flow measurement solution for water-based liquids.

22 Series Turbo-Flotm Probe


Here is an easy to install insertion meter with turbine meter accuracy. The low mass non-metallic turbine rotates in direct proportion to fluid velocity and can provide local flow rate and total information with no external power required. 4-20 mA signal outputs are also available for control and automation functions.
The 22 Series probe has its own integral screw jack mechanism for "hot tap" insertion through a 1.5 inch full port ball valve at pressures up to 400 psig. By rotating the crank handle at the top of the probe, the turbine is lowered through the open ball valve into the stream. What an improvement over the "tighten down nuts on three threaded rods in rotation" method!
This instrument is ideal for periodic sampling or permanent installation. It is often used as a flow prover for other metering devices in large line sizes.

ERDCO 25 Series Turbo-Flotm Probe


Here is the precision of a turbine meter with insertion meter ease of use. The low mass non-metallic turbine rotates in direct proportion to fluid velocity and can provide local flow rate and total information with no external power required. 4-20 mA signal outputs are also available for control and automation functions.
The 25 Series range offers high performance non-metallic materials of construction like DuPont Delrin® and PVC that are also more economical than stainless steel. Delrin is a particularly good choice for water applications and due to its high natural lubricity, it resists coating from organics and mineral salts. We recommend PVC construction for use in PVC piping systems.
Probe lengths for use in up to 10 inch diameter pipe sizes are available. A full compliment of instrumentation for indication of flow rate, totalization and control functions are available.

HP-302 Open Stream Velocity Meter


The HP-302 is a hand held turbine meter intended for field use. The turbine, when immersed in a flowing stream, rotates at a speed in direct linear proportion to the fluid velocity. A pulse signal is produced with each rotation of the turbine.
The patented design of the turbine and shroud offer unique capabilities. In combination, turbine and shroud are highly directional, enabling detection of stream patterns as well as measurement of velocity. By adjustment of a pivot, the turbine may be rotated over 90 degrees for a vertical velocity measurement and insertion into pipe discharge ends. Small size permits measurement of streams as shallow as 1.5 inches. In addition to the 3 foot probe, extensions may be used for an overall reach of 21 feet enabling sewer surveys from street level.


Please call Flow Factor at 216-765-4231 for more information or to order.
Their are almost infinite combinations so a meter can be built just for your application.
Please ask for our ERDCO expert, Jerry.

Or use our contact form HERE.








Sunday, January 20, 2013

Flow Factor sells Sump Pumps Systems

A sump pump is used in applications where excess rainwater or groundwater needs to be pumped away from a particular area. A sump pump sits inside a basin (also known as a sump) that collects this excess water.


A sump pump is a pump used to remove water that has accumulated in a water collecting sump basin, commonly found in the basement of homes. The water may enter via the perimeter drains of a basement waterproofing system, funneling into the basin or because of rain or natural ground water, if the basement is below the water table level.
Sump pumps are used where basement flooding happens regularly and to remedy dampness where the water table is above the foundation of a home. Sump pumps send water away from a house to any place where it is no longer problematic, such as a municipal storm drain or a dry well.
Pumps may discharge to the sanitary sewer in older installations. Once considered acceptable, this practice may now violate the plumbing code or municipal bylaws, because it can overwhelm the municipal sewage treatment system. Municipalities urge homeowners to disconnect and reroute sump pump discharge away from sanitary sewers. Fines may be imposed for noncompliance. Many homeowners have inherited their sump pump configurations and do not realize that the pump discharges to the sewer. If the discharge is fed to a laundry sink in the basement, it's likely going to the sewer.
Usually hardwired into a home's electrical system, sump pumps may have a battery backup. The home's pressurized water supply powers some pumps, eliminating the need for electricity at the expense of using potable water, potentially making them more expensive to operate than electrical pumps and creating an additional water disposal problem. Since a sump basin may overflow if not constantly pumped, a backup system is important for cases when the main power is out for prolonged periods of time, as during a severe storm.

There are generally two types of sump pumps — pedestal and submersible. The pedestal pump's motor is mounted above the sump, where it is more easily serviced, but is also more conspicuous. The pump impeller is driven by a long, vertical extension shaft and the impeller is in a scroll housing in the base of the pump. The submersible pump is entirely mounted inside the sump, and is specially sealed to prevent electrical short circuits.
Sump pump systems are also utilized in industrial and commercial applications to control water table-related problems in surface soil. An artesian aquifer or periodic high water table situation can cause the ground to become unstable due to water saturation. As long as the pump functions, the surface soil will remain stable. These sumps are typically ten feet in depth or more; lined with corrugated metal pipe that contains perforations or drain holes throughout. They may include electronic control systems with visual and audible alarms and are usually covered to prevent debris and animals from falling in.

Pump selection

The selection of a sump pump will rest heavily on the application in which it will be used. To select the appropriate sump pump, consider the following:[1]
  • Automatic vs. manual operation — Selection of a manual sump pump means that one will turn the pump on and off when appropriate. Selecting an automatic sump pump means that a switch is wired to the sump pump to turn it on or off at appropriate water levels. Automatic switches include pressure switches, low level pressure switches and float switches.
  • Power — Sump pump motive power will vary from 1/4 horsepower to multiple horsepower.
  • Head pressure — The head pressure of a sump pump describes the maximum height that the pump will move water. For instance, a sump pump with a 15 ft maximum head (also called a shutoff head) will raise water up 15 ft before it completely loses flow. Technically, head pressure is defined as an expression of a pressure in terms of the height of fluid; P = yρg, where y is the fluid column height, ρ is fluid density and g is the acceleration of gravity. Other considerations may be added to overall head pressure, including loss from elbows/bends and friction loss from long horizontal runs.
  • Power cord length — It is important to consider the length of the cord of any special switches that may be connected to the pump. Running a more powerful electrical motor a long distance from the main service panel will require heavier gauge wires to assure sufficient voltage at the motor for proper pump performance.
  • Phase and voltage — Sump pumps powered from the AC mains are available with single-phase three-phase motors. rated for 110-120, 220-240, or 460 volts. Three-phase power is typically not available in residential locations.
  • Water level sensing switch type — Pressure switches are fully enclosed, usually inside the pump body, making them immune to obstructions or floating debris in the sump basin. Float switches, particularly the types attached to the end of a short length of flexible electrical cable, can get tangled or obstructed, especially if the pump is prone to movement in the basin due to torque effects when starting and stopping. Pressure switches are typically factory set and not adjustable, while float switches can be adjusted in place to set the high and low water levels in the sump basin.
  • Backup system and alarm — If redundancy and an alert system are vital for operation of your sump pump, consider a backup system and/or alarm.

Backup components

A secondary, typically battery-powered sump pump can operate if the first pump fails. A battery powered secondary pump requires the following components in parallel with the above others:
  • A battery-driven 12 volt sump pump with its own water level sensor, piping, and check valve (the pipes usually join after the check valves to prevent reverse flow through the primary when the secondary unit is pumping);
  • It must be a marine deep cycle battery, or special long-life standby battery. Standard automobile batteries are not suitable for this application. Auto batteries are designed to deliver a high current for a short period. Sump pumps need a smaller current for a long time.
  • A trickle-charge battery charger. May alternately have a specialized controller to manage, monitor and test that the battery holding a charge.
Alternative sump pump systems can be driven by municipal water pressure. Water-powered sump pumps are similar to backup battery-driven systems with a separate pump, float and check valves. One can also use an ejector pump that uses an ordinary garden hose to supply high pressure water and another garden hose to carry the water away. Although such ejector pumps waste water and are relatively inefficient, they have the advantage of having no moving parts and offer the utmost in reliability.
If the backup sump system is rarely used, a component failure may not be noticed, and the system may fail when needed. Some battery control units test the system periodically and alert on failed electrical components.
A simple, battery-powered water alarm can be hung a short distance below the top of the sump to sound an alarm should the water level rise too high.

Pedestal style Sump Pump
















Ejector / non-electric / venturi style sump pump














Submersible Sump Pumps

    



Bak-Up Systems with Battery















Call Flow Factor with your Sum Pump Application
or use our contact form here.

216-765-4231

info@flowfactor.com