Showing posts with label Immersion Heater. Show all posts
Showing posts with label Immersion Heater. Show all posts

Sunday, October 27, 2019

Watlow Flanged Immersion Heaters

3"- 6" Flange Heaters with Baffles from WATLOW and Flow Factor


For a Quote, please use our Watlow Form HERE!








Watlow flanged immersion heaters are easy to install and maintain. Designed for heating liquids and gases in tanks and pressure vessels, ANSI flanged immersion heaters are ideal for applications requiring higher kilowatts.

Watlow flanged immersion heaters are made with WATROD or FIREBAR tubular elements brazed or welded to a flange. Stock flange heaters are equipped with a general purpose terminal enclosure.

Watlow Flanged immersion heaters, with FIREBAR elements, also answer the need for liquid immersion applications requiring high kilowatts in small tanks. The FIREBAR element's unique flat surface geometry packs more power in a smaller bundle, with lower watt density, making it especially well-suited for petroleum-based liquid heating applications.

Features and Benefits:

UL® and CSA component recognition.
ANSI and ANSI compatible 2, 2½, 3 thru 48 inch flanges.
Integral thermowells provide convenient temperature sensor insertion       and replacement without draining the fluid being heated.
Standard, general purpose terminal enclosure for easy access to wiring.
All units are inspected and/or tested to ensure element-to-flange pressure seals do not leak.

Specifications

Alloy 800 Material = 1600º Max. Temp and 100 Watt Density Max.
Stainless Steel Material = 1200º Max. Temp and 100 Watt Density Max.
Steel Material = 750º Max. Temp and 100 Watt Density Max.

Typical Applications
• Water: Deionized Demineralized Clean Potable Process • Industrial water rinse tanks • Vapor degreasers • Hydraulic oil, crude, asphalt • Lubricating oils at API specified watt densities • Air and gas flow • Caustic solutions • Chemical baths • Process air equipment • Boiler equipment • Freeze protection of any fluid • Anti-freeze (glycol) solutions • Paraffin

Options
Terminal Enclosures
General purpose terminal enclosures, without thermostats, are standard on all flange immersion heaters. Optional terminal enclosures include:
• General purpose with a single or double pole thermostat.
• Moisture resistant. Available with or without a single or double pole thermostat.
• Corrosion resistant. Available with or without a single or double pole thermostat.
• Explosion resistant Class 1, Div. 1 and 2, Groups B, C and D, T1-T6. Available with or without a single or double pole thermostat.
• Explosion/moisture resistant combinations. Available with or without a single or double pole thermostat.


Stand-off Terminal Enclosures
Stand-off terminal enclosures provide an air-insulating barrier between the flange and terminal enclosure by mounting the terminations and wiring away from the flange. Stand-off terminal enclosures are recommended whenever a process operating temperature exceeds 210°F (100°C). This helps minimize terminal enclosure temperatures.

Certified Enclosures
CSA, ATEX, IECEx or PESO certified enclosures protect wiring in hazardous gas environments.

ASME Pressure Vessel Code Welding
Flange assemblies can be provided with an ASME Section VIII, Div. I pressure vessel stamp upon request.

Thermostats
To provide process temperature control, Watlow offers optional single pole, single throw (SPST) and double pole, single throw (DPST) thermostats.
Unless otherwise specified, thermostats are mounted inside the terminal enclosure. Please verify that the thermostat’s sensing bulb outside diameter is compatible with the flange heater’s thermowell inside diameter.

Thermocouples
ASTM Type J or K thermocouples offer more accurate sensing of process and/or sheath temperatures. A thermocouple may be inserted into the thermowell or attached to the heater’s sheath.
Thermocouples are supplied with 120 in. (3050 mm) leads (longer lead lengths available). Unless otherwise specified, thermocouples are supplied with temperature ranges.
Using a thermocouple requires an appropriate temperature and power controller. These must be purchased separately. Watlow offers a wide variety of temperature and power controllers to meet virtually all applications. Temperature controllers can be configured to accept process variable inputs, too. Contact a Watlow representative for details.
To order, specify Type J or K thermocouple and lead length. Indicate if the thermocouple is for process temperature sensing or heater sheath high-limit protection. Please specify if the flange heater will be mounted vertical or horizontal in the tank. If vertical, specify if the housing is on top or bottom.
If the flange heater is part of an in-line circulation heating application, indicate flow direction relative to the heater’s enclosure.F

Wattages and Voltages
Watlow routinely supplies flange immersion heaters with 240 to 480VAC as well as wattages from 150 watts to one megawatt.
If required, Watlow will make heaters with voltage up to 600VAC and wattage beyond one megawatt.

Selected Watlow 3 inch Flange Heater part Numbers:
Watlow FMN715J10 6 kw , 120 volts
Watlow FMN715J11S 6 kw 480 volts
Watlow FMN721J10S  9 kw  120 volts
Watlow FMN721J11S  9 kw  480 volts
Watlow FMN727A3S 12 kw  240 volts
Watlow FMN727A5S 12 kw  480 volts
Watlow FMN732J3S  15 kw  240 volts
Watlow FMN732J5S  15 kw  480 volts
Watlow FMN738A3S  18 kw  240 volts
Watlow FMN738A5S  18 kw  480 volts
Watlow FMN751A5S  25 kw  480 volts
Watlow FMN760J5S  30 kw  480 volts

Selected Watlow 4 inch Flange Heater part Numbers:
Watlow FON715J10W  12 kw 240 volts
Watlow FON715J5W 12 kw 480 volts
Watlow FON721J10W 18 kw 240 volts
Watlow FON721J5W  18 kw  480 volts
Watlow FON727A10W  24 k  240 volts
Watlow FON727A5W  24 kw  480 volts
Watlow FON732J3W 30 kw  240 volts
Watlow FON732J5W   30 kw  480 volts
Watlow FON738A3W  36 kw  240 volts
Watlow FON738A5W  36 kw  480 volts
Watlow FON751J5W   50 kw  480 volts

Selected Watlow 5 inch Flange Heater part Numbers:
Watlow FNN715J3S  12 kw  240 volts
Watlow FNN715J5W  12 kw  480 volts
Watlow FNN721J3S  18 kw  240 volts
Watlow FNN721J5W  18 kw  480 volts
Watlow FNN727A3S  24 kw  240 volts
Watlow FNN727A5W  24 kw  480 volts
Watlow FNN732J3S  30 kw  240 volts
Watlow FNN732J5W  30 kw  480 volts
Watlow FNN738A3S  36 kw 240 volts
Watlow FNN738A5W  36 kw 480 volts
Watlow FNN751A5S  50 kw  480 volts
Watlow FNN760J5W  60 kw  480 volts

Selected Watlow 6 inch Flange Heater part Numbers:
Watlow FPN715G10XS  30 kw  240 volts
Watlow FPN715G5XW  30 kw  480 volts
Watlow FPN721G10XS  45 kw  240 volts
Watlow FPN721G5XW  45 kw  480 volts
Watlow FPN726R3XS  60 kw  240 volts
Watlow FPN726R5XW  60 kw  480 volts
Watlow FPN732G3XS  75 kw  240 volts
Watlow FPN732G5XW  75 kw  480 volts
Watlow FPN737R3XS  90 kw  240 volts
Watlow FPN737R5XW  90  kw  480 volts
Watlow FPN750R5XW  125  kw  480 volts
Watlow FPN760G5XW  150 kw  480 volts


For a Watlow Flanged Immersion Heater Quote, please use our Watlow Form HERE! 

Flow Factor
216-765-4231

Watlow Flanged Immersion Heaters  Watlow Flanged Immersion Heaters  Watlow Flanged Immersion Heaters

Thursday, September 26, 2019

Watlow FIREBAR® Heaters from Flow Factor

FIREBAR® Single/Double-Ended Heaters by Watlow


Get a Quote HERE!













Watlow FIREBAR heating elements provide added heating performance over standard round tubular heating elements—especially for immersion applications in petroleum-based liquids requiring high kilowatts. 
The FIREBAR's unique flat surface geometry packs more power in shorter elements and assemblies, along with a host of other performance improvements. These include:

-Minimizing coking and fluid degrading

-Enhancing the flow of fluid past the element's surface to carry heat from the sheath

-Improving heat transfer with a significantly larger boundary layer allowing much more liquid     to flow up and across the sheath's surface

Watlow FIREBAR elements are available in single- and double-ended constructions with one inch or 5⁄8 inch heights. These two configuration variables make it possible to use FIREBAR elements instead of round tubular elements in virtually all applications.

70 percent greater surface area per linear inch compared to a 0.430 in. (11 mm) diameter round tubular heater

Compacted MgO insulation maximizes thermal conductivity and dielectric strength

Precision wound nickel-chromium resistance wires

0.040 in. (1 mm) thick MgO walls transfer heat more efficiently

Three resistance coil design readily adapts to a variety of electrical sources and wattages outputs














Get a Quote HERE!

Flow Factor
216-765-4231

Saturday, September 14, 2019

Watlow Over-The-Side Immersion Heaters

Flow Factor and Over-The-Side Immersion Heaters

Contact Flow Factor HERE!

L and O Shaped Immersion Heaters

Over-The-Side immersion heaters are ideal for heating water, Oils and solvents, salts and acids. These Immersion heaters provide application versatility with optional sheath materials, kilowatt (KW) ratings, terminal enclosures and mounting methods.  Voltages are can be 120, 240 or 480 and KW ratings from 3 to 18.  (Specials could be made as well.)

The Over-The-Side L and O shaped Immersion "install from the top" heaters slide easily into tanks, with the heated portion immersed along the side or bottom. The O-T-S immersion heaters can come equipped with integral thermostats, thermal wells and sensors if needed for temperature control or monitoring. Sludge legs can be added as well to keep the bottom style heaters above the tank bottom. The heater riser can be up to 60 feet if necessary, common riser height is 39 and 51 inches.

Applications are:
Water Heating
Freeze Protection
Viscous oils
Storage Tanks
Degreasing Tanks
Solvents
Salts
Caustic Solutions
Parafin

Standard L shaped 240 volt part numbers are:

OLN714L3W  3 KW 48 Watt Density
OLN722L3W  6 KW 48 Watt Density
OLN730C3W  9 KW 48 Watt Density
OLN737L3W  12 KW 48 Watt Density
OLN745C3W  15 KW 48 Watt Density
OLN752L3W  18 KW 48 Watt Density
OLNA22L3W  3 KW  23 Watt Density
OLNA37L3W  6 KW  23 Watt Density
OLNA52L3W  9 KW  23 Watt Density
OLS722L3W   3 KW  23 Watt Density
OLS737L3W   6 KW  23 Watt Density
OLS752L3W   9 KW  23 Watt Density

Standard L shaped 480 volt part numbers are:

OLN714L13W  3 KW  48 Watt Density
OLN722L5W    6 KW  48 Watt Density
OLN730C5W    9 KW  48 Watt Density
OLN737L5W  12 KW  48 Watt Density
OLN745C5W  15 KW  48 Watt Density
OLN752L5W  18 KW  48 Watt Density
OLNA22L5W  3 KW   23 Watt Density
OLNA37L5W  6 KW  23 Watt Density
OLNA52L5W  9 KW  23 Watt Density
OLS722L5W   3 KW   23 Watt Density
OLS737L5W   6 KW   23 Watt Density
OLS752L5W   9 KW   23 Watt Density

Over-The-Side Immersion Heaters - L and O Shaped





















Standard O shaped 240 volt part numbers are:

ORN710N3W  3 KW 48 Watt Density
ORN713J3W  6 KW 48 Watt Density
ORN716A3W  9 KW 48 Watt Density
ORN718J3W  12 KW 48 Watt Density
ORN721E3W  15 KW 48 Watt Density
ORN723J3W  18 KW 48 Watt Density
ORNA13J3W  3 KW  23 Watt Density
ORNA18J3W  6 KW  23 Watt Density
ORNA23J3W  9 KW  23 Watt Density
ORS713J3W   3 KW  23 Watt Density
ORS718J3W   6 KW  23 Watt Density
ORS723J3W   9 KW  23 Watt Density

Standard O shaped 480 volt part numbers are:

ORN710N13W  3 KW 48 Watt Density
ORN713J5W  6 KW 48 Watt Density
ORN716A5W  9 KW 48 Watt Density
ORN718J5W  12 KW 48 Watt Density
ORN721E5W  15 KW 48 Watt Density
ORN723J5W  18 KW 48 Watt Density
ORNA13J5W  3 KW  23 Watt Density
ORNA18J5W  6 KW  23 Watt Density
ORNA23J5W  9 KW  23 Watt Density
ORS713J5W   3 KW  23 Watt Density
ORS718J5W   6 KW  23 Watt Density
ORS723J5W   9 KW  23 Watt Density

Please use our Parts Form HERE for a quote/


FLOW FACTOR
216-765-4231
www.flowfactor.com


Thursday, October 31, 2013

Watlow FIREBAR 1.25 Screw Plug Immersion Heaters

Fire Bar Screw Plug Immersion Heaters by Watlow and Flow Factor

Watlow FIREBAR 1.25 inch Screw Plug Immersion heaters (BDNF Series) for heating Process water. The screw plug is made of 304 Stainless Steel and the element is made of Alloy 800. The watt density is about 45 watts per square inch.

Also available with integral thermostats in two ranges 60-250 or 100-550 degrees F.


The FIREBAR has a few advantages over a tubular element.

The FIREBAR element has three resistant wires and thus can be wired in single or three phase with only a single element.

The FIREBAR element has lower watt density for the same length of immersion, or put another way it can have higher wattage with less immersion depth.

The FIREBAR design has better heat transfer due to the design of the element than the round tubular element, it creates more surface area within the medium.

Call Flow Factor for more information or to order.  216-765-4231
Email to info@flowfactor.com


Tuesday, September 24, 2013

Watlow Screw Plug Immersion Heaters - 2 1/2 Inch Plugs

Flow Factor sells Watlow Screw Plug Immersion Heaters


Watlow is a world leader in the manufacture of Electric heating elements.  Immersion heaters are made with electric elements with a fitting so that the heater can protrude though the tank wall for direct immersion into the liquid or medium being heated.  The elements can be made of Copper, Stainless Steel, Steel or Alloy 800 (a nickel enriched metal).  Watlow uses Alloy 800 for the majority of their heaters and Stainless for specific types of liquids like DI Water.  With the cost of copper skyrocketing, Watlow has discontinued its' use.  n this blog are the most common size of screw plug heater the 2 1/2 inch size.  2.5 inch screw plug are popular since a bundle of three elements can be used along with a thermowell.  The common voltages are 240 and 480 in either 1 phase or 3 phase, three phase being more common due to the lower amp draw and the widespread use of 480 within USA manufacturing facilities.

Heaters in this blog are designed for use with water or liquids similar in viscosity of water.  Oils and other more viscous materials will need different wattages and materials of construction than these water heaters.

Watlow's BLN (3 elements) series Screw Plug Immersion heaters are for CLEAN water have a 2 1/2 inch NPT(M) Stainless Steel Screw Plug and nickel alloy 800 electric heating elements. The Watt Density is between 59 and 61 and total wattages from 2 to 18 kilowatts (KW). Voltages come in 120 single phase or 240 and 480 three phase with General Purpose (NEMA 1) enclosure. The units with the built in Thermostat have a range of 30-110F, 60-250F or 100-550F.  Please note that running the elements dry will cause them to burn out.  Use a low water cut off or liquid level control to protect the heating elements.




Watlow BLN77L1S, Immersion Heater, 3 kw, 120 VAC/1 phase, Alloy 800 Elements

Watlow BLN77L3S4, Immersion Heater, 3 kw, 240 VAC/1 ph, Alloy 800 Elements, 30-110 Tstat

Watlow BLN77L13S7A, Immersion Heater, 3 kw, 480 VAC/1 ph, Alloy 800 Elements, 100-550 Tstat

Watlow BLN710L1S, Immersion Heater, 4.5 kw, 120 VAC/1 phase, Alloy 800 Elements

Watlow BLN710L3S4, Immersion Heater, 4.5 kw, 240 VAC/1 ph, Alloy 800 Elements, 30-110 Tstat

Watlow BLN610K13S7A, Immersion Heater, 4.5 kw, 480 VAC/1 ph, Alloy 800 Elements, 100-550 Tstat

Watlow BLN720L3S, Immersion Heater, 9 kw, 240 VAC/3 phase, Alloy 800 Elements

Watlow BLN720L3S4, Immersion Heater, 9 kw, 240 VAC/1 ph, Alloy 800 Elements, 30-110 Tstat

Watlow BLN726C5S, Immersion Heater, 12 kw, 480 VAC/3 phase, Alloy 800 Elements

Watlow BLNF15C3S, Immersion Heater, 15 kw, 240 VAC/3 phase, Alloy 800 Elements

Watlow BLNF28L5S, Immersion Heater, 32 kw, 480 VAC/3 phase, Alloy 800 Elements


Watlow's BLN (3 elements) series Screw Plug Immersion heaters are for CLEAN water have a 2 1/2 inch NPT(M) Stainless Steel Screw Plug and nickel alloy 800 electric heating elements. The Watt Density is between 59 and 61 and total wattages from 2 to 18 kilowatts (KW). Voltages come in 120 single phase or 240 and 480 three phase with Moisture Resistant/Explosion resistant (NEMA 4 & 7) enclosure. The units with the built in Thermostat have a range of 30-110F, 60-250F or 100-550F.  Please note that running the elements dry will cause them to burn out.  Use a low water cut off or liquid level control to protect the heating elements.




Watlow BLN77L1C, Immersion Heater, 3 kw, 120 VAC/1 phase, Alloy 800 Elements

Watlow BLN77L3C4, Immersion Heater, 3 kw, 240 VAC/3 phase, Alloy 800 Elements, 30-110 Tstat

Watlow BLN77L13C7A, Immersion Heater, 3 kw, 480 VAC/3 phase, Alloy 800 Elements, 100-550 Tstat

Watlow BLN710L1C, Immersion Heater, 4.5 kw, 120 VAC/1 phase, Alloy 800 Elements

Watlow BLN710L3C4, Immersion Heater, 4.5 kw, 240 VAC/3 phase, Alloy 800 Elements, 30-110 Tstat

Watlow BLN610K13C7A, Immersion Heater, 4.5 kw, 480 VAC/3 phase, Alloy 800 Elements, 100-550 Tstat

Watlow BLN720L3C, Immersion Heater, 9 kw, 240 VAC/3 phase, Alloy 800 Elements

Watlow BLN720L3C4, Immersion Heater, 9 kw, 240 VAC/3 phase, Alloy 800 Elements, 30-110 Tstat

Watlow BLN720L5C, Immersion Heater, 9 kw, 480 VAC/3 phase, Alloy 800 Elements

Watlow BLN726C5C, Immersion Heater, 12 kw, 480 VAC/3 phase, Alloy 800 Elements

Watlow BLNF15C3C, Immersion Heater, 15 kw, 240 VAC/3 phase, Alloy 800 Elements

Watlow BLNF28L5C, Immersion Heater, 32 kw, 480 VAC/3 phase, Alloy 800 Elements

These BLN (3 elements) series Watlow Screw Plug Immersion heaters for PROCESS water or solution water have a 2 1/2 inch NPT(M) Stainless Steel Screw Plug and nickel alloy 800 electric heating elements. The Watt Density is between 47 and 49 and total wattages from 2 to 18 kilowatts (KW). Voltages come in 120 single phase or 240 and 480 three phase with General Purpose (NEMA 1) enclosure. The units with the built in Thermostat have a range of 30-110F, 60-250F or 100-550F. Use of a liquid level control is recommended to protect the heating elements from "running dry"!  The use of a contactor may also be required to switch a high amp load.

Watlow BLN79G3S, Immersion Heater, 3 kw, 240 VAC/3 phase, Alloy 800 Elements

Watlow BLN79G3S5A, Immersion Heater, 3 kw, 240 VAC/1 ph, Alloy 800 Elements, 60-250 Tstat

Watlow BLN79G5S4, Immersion Heater, 3 kw, 480 VAC/1 ph, Alloy 800 Elements, 30-110 Tstat

Watlow BLN712R1S, Immersion Heater, 4.5 kw, 120 VAC/1 phase, Alloy 800 Elements

Watlow BLN712R3S5A, Immersion Heater, 4.5 kw, 240 VAC/1 ph, Alloy 800 Elements, 60-250 Tstat

Watlow BLN712R5S7A, Immersion Heater, 4.5 kw, 480 VAC/1 ph, Alloy 800 Elements, 100-550 Tstat

Watlow BLN719R3S4, Immersion Heater, 7.5 kw, 240 VAC/1 ph, Alloy 800 Elements, 30-110 Tstat

Watlow BLN719R5S, Immersion Heater, 7.5 kw, 480 VAC/3 phase, Alloy 800 Elements

Watlow BLN724R3S7A, Immersion Heater, 9 kw, 240 VAC/1 ph, Alloy 800 Elements, 100-550 Tstat

Watlow BLN724R5S, Immersion Heater, 9 kw, 480 VAC/3 phase, Alloy 800 Elements

Watlow BLN739R5S, Immersion Heater, 15 kw, 480 VAC/3 phase, Alloy 800 Elements

Watlow BLN747G5S, Immersion Heater, 18 kw, 480 VAC/3 phase, Alloy 800 Elements

Watlow Heater Cmpany BLN (3 elements) series Screw Plug Immersion heaters for PROCESS water have a 2 1/2 inch NPT(M) Stainless Steel Screw Plug and nickel alloy 800 electric heating elements. The Watt Density is between 47 and 49 and total wattages from 2 to 18 kilowatts (KW). Voltages come in 120 single phase or 240 and 480 three phase with Moisture Resistant/Explosion resistant (NEMA 4 & 7) enclosure. The units with the built in Thermostat have a range of 30-110F, 60-250F or 100-550F. Liquid level controls should be used to protect the heater from turning on with no liquid present.  Call Flow Factor for Explosion Proof Level control.  

Watlow BLN79G1C, Immersion Heater, 3 kw, 120 VAC/1 phase, Alloy 800 Elements

Watlow BLN79G3C5A, Immersion Heater, 3 kw, 240 VAC/3 phase, Alloy 800 Elements, 60-250 Tstat

Watlow BLN79G5C7A, Immersion Heater, 3 kw, 480 VAC/3 phase, Alloy 800 Elements, 100-550 Tstat

Watlow BLN717G3C, Immersion Heater, 6 kw, 240 VAC/3 phase, Alloy 800 Elements

Watlow BLN717G3C7A, Immersion Heater, 6 kw, 240 VAC/3 phase, Alloy 800 Elements, 100-550 Tstat

Watlow BLN717G5C5A, Immersion Heater, 6 kw, 480 VAC/3 phase, Alloy 800 Elements, 60-250 Tstat

Watlow BLN719R3C7A, Immersion Heater, 7.5 kw, 240 VAC/3 phase, Alloy 800 Elements, 100-550 Tstat

Watlow BLN724R3C, Immersion Heater, 9 kw, 240 VAC/3 phase, Alloy 800 Elements

Watlow BLN724R3C7A, Immersion Heater, 9 kw, 240 VAC/3 phase, Alloy 800 Elements, 100-550 Tstat

Watlow BLN724R5C, Immersion Heater, 9 kw, 480 VAC/3 phase, Alloy 800 Elements

Watlow BLN732G5C, Immersion Heater, 12 kw, 480 VAC/3 phase, Alloy 800 Elements

Watlow BLN739R5C, Immersion Heater, 15 kw, 480 VAC/3 phase, Alloy 800 Elements

Watlow BLN747G5C, Immersion Heater, 18 kw, 480 VAC/3 phase, Alloy 800 Elements

Watlow's BLR (3 elements) series Screw Plug Immersion heaters for DI OR DEMINERALIZED water have a 2 1/2 inch NPT(M) Stainless Steel Screw Plug and STAINLESS STEEL electric heating elements. The Watt Density is between 59 and 61 and total wattages from 2 to 18 kilowatts (KW). Voltages come in 120 single phase or 240 and 480 three phase with General Purpose (NEMA 1) enclosure. The units with the built in Thermostat have a range of 30-110F, 60-250F or 100-550F. Liquid Level control is important to protect the elements from burning up in dry air.  Over Temperature limits are also a good idea.

Watlow BLR77L1S, Immersion Heater, 3 kw, 120 VAC/1 phase, Stainless Steel Elements

Watlow BLR77L3S4, Immersion Heater, 3 kw, 240 VAC/1 ph, Stainless Steel Elements, 30-110 Tstat

Watlow BLR77L5S5A, Immersion Heater, 3 kw, 480 VAC/1 ph, Stainless Steel Elements, 60-250 Tstat

Watlow BLR710L5S, Immersion Heater, 4.5 kw, 480 VAC/3 phase, Stainless Steel Elements

Watlow BLR714L3S4, Immersion Heater, 6 kw, 240 VAC/1 ph, Stainless Steel Elements, 30-110 Tstat

Watlow BLR714L5S5A, Immersion Heater, 6 kw, 480 VAC/1 ph, Stainless Steel Elements, 60-250 Thermostat

Watlow BLR717L3S4, Immersion Heater, 7.5 kw, 240 VAC/1 ph, Stainless Steel Elements, 30-110 Thermostat

Watlow BLR717L5S, Immersion Heater, 7.5 kw, 480 VAC/3 phase, Stainless Steel Elements

Watlow BLR720L3S4, Immersion Heater, 9 kw, 240 VAC/1 ph, Stainless Steel Elements, 30-110 Thermostat

Watlow BLR720L3S7A, Immersion Heater, 9 kw, 240 VAC/1 ph, Stainless Steel Elements, 100-550 Thermostat

Watlow BLR726C5S, Immersion Heater, 12 kw, 480 VAC/3 phase, Stainless Steel Elements

Watlow BLR731L5S, Immersion Heater, 15 kw, 480 VAC/3 phase, Stainless Steel Elements

Watlow BLR737C5S, Immersion Heater, 18 kw, 480 VAC/3 phase, Stainless Steel Elements

Watlow's BLR (3 elements) series Screw Plug Immersion heaters for DI OR DEMINERALIZED water have a 2 1/2 inch NPT(M) Stainless Steel Screw Plug and nickel alloy 800 electric heating elements. The Watt Density is between 59 and 61 and total wattages from 2 to 18 kilowatts (KW). Voltages come in 120 single phase or 240 and 480 three phase with Moisture Resistant/Explosion resistant (NEMA 4 & 7) enclosure. The units with the built in Thermostat have a range of 30-110F, 60-250F or 100-550F.

Watlow BLR77L1C, Immersion Heater, 3 kw, 120 VAC/1 phase, Stainless Steel Elements, Ex. Proof

Watlow BLR77L3C4, Immersion Heater, 3 kw, 240 VAC/3 phase, Stainless Steel Elements, 30-110 Thermostat

Watlow BLR77L5C7A, Immersion Heater, 3 kw, 480 VAC/3 phase, Stainless Steel Elements, 100-550 Thermostat

Watlow BLR710L3C, Immersion Heater, 4.5 kw, 240 VAC/3 phase, Stainless Steel Elements, Ex. Proof

Watlow BLR710L3C7A, Immersion Heater, 4.5 kw, 240 VAC/3 ph, Stainless Steel Elements, 100-550 Thermostat

Watlow BLR710L5C5A, Immersion Heater, 4.5 kw, 480 VAC/3 ph, Stainless Steel Elements, 60-250 Thermostat

Watlow BLR714L5C4, Immersion Heater, 6 kw, 480 VAC/3 phase, Stainless Steel Elements, 30-110 Thermostat

Watlow BLR717L3C, Immersion Heater, 7.5 kw, 240 VAC/3 phase, Stainless Steel Elements, Ex. Proof

Watlow BLR717L5C, Immersion Heater, 7.5 kw, 480 VAC/3 phase, Stainless Steel Elements, Ex. Proof

Watlow BLR720L3C5A, Immersion Heater, 9 kw, 240 VAC/3 phase, Stainless Steel Elements, 60-250 Thermostat

Watlow BLR720L5C, Immersion Heater, 9 kw, 480 VAC/3 phase, Stainless Steel Elements, Ex. Proof

Watlow BLR726C5C, Immersion Heater, 12 kw, 480 VAC/3 phase, Stainless Steel Elements, Explosion Proof Housing

Watlow BLR731L5C, Immersion Heater, 15 kw, 480 VAC/3 phase, Stainless Steel Elements, Explosion Proof


Watlow BLR737C5C, Immersion Heater, 18 kw, 480 VAC/3 phase, Stainless Steel Elements, Explosion Proof Housing




www.flowfactor.com
866-360-9830