Watlow FIREBAR® Heaters from Flow Factor

FIREBAR® Single/Double-Ended Heaters by Watlow


Get a Quote HERE!













Watlow FIREBAR heating elements provide added heating performance over standard round tubular heating elements—especially for immersion applications in petroleum-based liquids requiring high kilowatts. 
The FIREBAR's unique flat surface geometry packs more power in shorter elements and assemblies, along with a host of other performance improvements. These include:

-Minimizing coking and fluid degrading

-Enhancing the flow of fluid past the element's surface to carry heat from the sheath

-Improving heat transfer with a significantly larger boundary layer allowing much more liquid     to flow up and across the sheath's surface

Watlow FIREBAR elements are available in single- and double-ended constructions with one inch or 5⁄8 inch heights. These two configuration variables make it possible to use FIREBAR elements instead of round tubular elements in virtually all applications.

70 percent greater surface area per linear inch compared to a 0.430 in. (11 mm) diameter round tubular heater

Compacted MgO insulation maximizes thermal conductivity and dielectric strength

Precision wound nickel-chromium resistance wires

0.040 in. (1 mm) thick MgO walls transfer heat more efficiently

Three resistance coil design readily adapts to a variety of electrical sources and wattages outputs














Get a Quote HERE!

Flow Factor
216-765-4231

Saturday, September 14, 2019

Watlow Over-The-Side Immersion Heaters

Flow Factor and Over-The-Side Immersion Heaters

Contact Flow Factor HERE!

L and O Shaped Immersion Heaters

Over-The-Side immersion heaters are ideal for heating water, Oils and solvents, salts and acids. These Immersion heaters provide application versatility with optional sheath materials, kilowatt (KW) ratings, terminal enclosures and mounting methods.  Voltages are can be 120, 240 or 480 and KW ratings from 3 to 18.  (Specials could be made as well.)

The Over-The-Side L and O shaped Immersion "install from the top" heaters slide easily into tanks, with the heated portion immersed along the side or bottom. The O-T-S immersion heaters can come equipped with integral thermostats, thermal wells and sensors if needed for temperature control or monitoring. Sludge legs can be added as well to keep the bottom style heaters above the tank bottom. The heater riser can be up to 60 feet if necessary, common riser height is 39 and 51 inches.

Applications are:
Water Heating
Freeze Protection
Viscous oils
Storage Tanks
Degreasing Tanks
Solvents
Salts
Caustic Solutions
Parafin

Standard L shaped 240 volt part numbers are:

OLN714L3W  3 KW 48 Watt Density
OLN722L3W  6 KW 48 Watt Density
OLN730C3W  9 KW 48 Watt Density
OLN737L3W  12 KW 48 Watt Density
OLN745C3W  15 KW 48 Watt Density
OLN752L3W  18 KW 48 Watt Density
OLNA22L3W  3 KW  23 Watt Density
OLNA37L3W  6 KW  23 Watt Density
OLNA52L3W  9 KW  23 Watt Density
OLS722L3W   3 KW  23 Watt Density
OLS737L3W   6 KW  23 Watt Density
OLS752L3W   9 KW  23 Watt Density

Standard L shaped 480 volt part numbers are:

OLN714L13W  3 KW  48 Watt Density
OLN722L5W    6 KW  48 Watt Density
OLN730C5W    9 KW  48 Watt Density
OLN737L5W  12 KW  48 Watt Density
OLN745C5W  15 KW  48 Watt Density
OLN752L5W  18 KW  48 Watt Density
OLNA22L5W  3 KW   23 Watt Density
OLNA37L5W  6 KW  23 Watt Density
OLNA52L5W  9 KW  23 Watt Density
OLS722L5W   3 KW   23 Watt Density
OLS737L5W   6 KW   23 Watt Density
OLS752L5W   9 KW   23 Watt Density

Over-The-Side Immersion Heaters - L and O Shaped





















Standard O shaped 240 volt part numbers are:

ORN710N3W  3 KW 48 Watt Density
ORN713J3W  6 KW 48 Watt Density
ORN716A3W  9 KW 48 Watt Density
ORN718J3W  12 KW 48 Watt Density
ORN721E3W  15 KW 48 Watt Density
ORN723J3W  18 KW 48 Watt Density
ORNA13J3W  3 KW  23 Watt Density
ORNA18J3W  6 KW  23 Watt Density
ORNA23J3W  9 KW  23 Watt Density
ORS713J3W   3 KW  23 Watt Density
ORS718J3W   6 KW  23 Watt Density
ORS723J3W   9 KW  23 Watt Density

Standard O shaped 480 volt part numbers are:

ORN710N13W  3 KW 48 Watt Density
ORN713J5W  6 KW 48 Watt Density
ORN716A5W  9 KW 48 Watt Density
ORN718J5W  12 KW 48 Watt Density
ORN721E5W  15 KW 48 Watt Density
ORN723J5W  18 KW 48 Watt Density
ORNA13J5W  3 KW  23 Watt Density
ORNA18J5W  6 KW  23 Watt Density
ORNA23J5W  9 KW  23 Watt Density
ORS713J5W   3 KW  23 Watt Density
ORS718J5W   6 KW  23 Watt Density
ORS723J5W   9 KW  23 Watt Density

Please use our Parts Form HERE for a quote/


FLOW FACTOR
216-765-4231
www.flowfactor.com


Sunday, April 30, 2017

Barksdale BPS Pressure Switch

Pressure Switches From Flow Factor

BPS3000 Electronic Pressure Switch sets the benchmark




Barksdale BPS Switch

  • Compact and modern design
  • Rotatable 320° display and electrical connection
  • 4-digit 14 segment LED display
  • High EMI protection 
  • IP65/IP67 enclosure rating
We are pleased to announce the first release of the Generation 3000 Series: the BPS3000, an electronic dual pressure switch with a 4-digit display. The BPS3000 is part of Barksdale’s new Generation 3000 Series of electronic products that will soon include Temperature, Level and Flow sensor technology.

With a panel height just under four inches, and a diameter well under two inches, the BPS3000 allows for a compact installation. The large 14 segment LED angled display is aesthetically pleasing and allows clear readability of the process pressure. Even if the unit must be mounted upside down, the internal software is capable of rotating its display 180°. Plus, the 320° rotatable electrical connection and display housing, makes installing the unit very simple helping reduce installation costs allowing for versatility of installation method and location.  Robust EMI protection allowing for stable output in today’s factories where EMF and high powered walkie-talkies are present. Additionally, the IP67 class rated housing makes this unit suitable for the wettest of environments, and even full submersion.
Pressure ranges are available from 0 to 3 psi up to 0 to 9000 psi, with absolute pressure ranges up to 150 psia. Multiple process connections are offered as standard from ¼” NPT to 7/16” SAE just to name a few. The BPS3000 also offers
transmitter functionality by supplying analogue output signals 0 to 10 V DC to 4 to 20 mA respectively. The readable range can be set during installation enabling more flexibility.

Flow Factor

Friday, May 30, 2014

Capacitance Level Control Definitions


ROBERTSHAW CAPACITANCE LEVEL

For a quote or part number ID, please click HERE.

Capacitance Level Definitions

High Level Fail Safe (HLFS):
Relay de-Energizes on High Alarm condition. Thus the alarm condition with power failure.  Example: To Keep tank from overfilling with power failure.

Low Level Fail Safe (LLFS):
Relay de_Energizes on Low Alarm Condition. Thus alarm condition with power failure. Example: To Keep pump from running dry and burning up with a ower failure.

Time Delay:
Used for Splashing or wavy processes to prevent cycling on and off.

Response Time:
How fast the unit goes to alarm condition after set point is reached.

C, NO, NC Contacts:
Contacts are normally shown in the non-energized alarm condition – no power, shelf condition.  Relay energizes in non-alarm condition.

POINT LEVEL

ZERO:
This is the SET POINT. Where the desired actuation is to occur.

DIFFERENTIAL:
This is the distance, in Pico-Farads, inches or feet from ZERO to where the RESET is to occur. Sometimes called Deadband or Pump On – Pump Off.

CONTINUOUS LEVEL

ZERO:
The 0% Level point on the sensing probe.

100%:
The full level point on the sensing probe.

SPAN:
The distance in Pico-Farads, from the Zero Level point to the FULL Level Point (100%).

TERMINAL CAPACITANCE:
The Minimum amount of Capacitance present when no product is present in the vessel.
This is:
The Capacitance of the Probe Gland (and sheath and colling extension, if used) PLUS
The Capacitance generated between the probe and the vessel with air as the dielectric. In other words, the absolute minimum value of capacitance generated in that particular probe/vessel installation.

TERMINAL / SPAN RATIO:
The Terminal Capacitance divided by the span capacitance. This ratio must not be exceeded where specified on product specification sheets (all instruments do not have this restriction).

Terminal Adjustment/Zero Adjustment Range/Maximum Zero Suppression:
This is the maximum “Zero Suppression” of the capacitance value at the zero point level in the vessel.  This value cannot be exceeded.

Capacitance Change:
The amount of capacitance difference between ZERO and 100% points in the continuous level measuring instruments; the amount of capacitance difference between product and no product in point level measuring instruments without differential; or the amount of capacitance difference between ZERO and Differential points in Point Level measuring instruments with differential adjustment.

TOTAL CAPACITANCE:
This is the total capacitance value (not capacitance change) with tank of vessel at the 100% level (includes terminal capacitance). This value must not exceed the maximum span of the instrument.

866-360-9830

Sunday, February 21, 2010

Penberthy Magnetic Level Gages


Penberthy's MULTIVIEW™ Magnetic Liquid Level Gages can be built to serve practically any process industry situation. From the simplest operation to the most severe, corrosive environment, Penberthy can construct a system to best suit your company’s requirements. As pioneers in magnetic gage level indication and as creators of the unique concentric magnet design, Penberthy has the expertise to know what design, specifications and options best fit any given application. Contact a Penberthy representative to discuss specific duty requirements in your operation.

MULTIVIEW™ Magnetic Liquid Level Gages utilize a communicating chamber constructed of 2-1/2" pipe which is connected to the process tank with either side or end connections. A float with a self-enclosed magnet is custom sized and weighted to float at the surface of the process liquid to be monitored. The float is then installed in the communicating chamber.

The industry-unique concentric magnet in MULTIVIEW™ gages provides a more consistent magnetic field than conventional magnet designs.

Construction Materials AvailablePenberthy offers a wide range of materials, including:

304/304L STS
316/316L STS
Alloy-20
Monel
Titanium
Hastelloy-C
PVC
CPVC
PVDF
Tefzel® Lined
Halar® Lined

Typical Process Applications
Sodium Hypochlorite
Boiler Feedwater Tank
Hydrochloric Acid
Stop Oil
LPG
Interface
Dowtherm®
Sulfuric Acid
Hydrogen Sulfide
Oil/Water Separator
Sodium Hydroxide
Liquid Nitrogen
Flare Drums
Phosgene
Jet Fuel
Molten Sulfur
Sour Oil
Diesel Fuel
Deionized Water
Sumps
Freon
Liquid Ethylene
Water
Underground Storage
Benzene
Asphalt Settler
Acetic Acid
Liquids & Slurries

Follower Style Indicator

In MG Follower-Type models, the unit consists of a hermetically-sealed tube in a protective view housing. Within this tube is a gold anodized aluminum follower which will mirror level changes in the process tank. This entire assembly is attached to the communicating chamber where the follower is magnetically coupled with the float. Because the follower and float are magnetically linked, liquid level changes in the process tank will cause both float and follower to rise and fall in unison. The result is a precise indication of the liquid level within the vessel.

Flag Style Indicator

MG Flag-Type monitors provide a more secure link between the indicator and float. The view housing is sealed and consists of a single column assembly of aluminum flags within an extruded aluminum channel. These flags are anodized with black on one side and gold on the other. Each flag houses a small magnet and is assembled on a single, individual axle. As the float in the communicating chamber rises and falls, the magnetic interaction between float and flag magnets cause the flags to rotate 180°. These changes are shown through contrasting colors – black above and gold below the liquid level.

To insure trouble-free operation, Penberthy's flags are magnetically interlocked and utilize mechanical stops. This prevents over-rotation. Penberthy's redundant axle system prevents binding, with each flag allowed to rotate on the axle and each axle free to rotate in the channel. This method of indication is always accurate, regardless of the speed of process level change or vibration.

Switches can be added to the level gage for point level control.

MGS Switches provide non-intrusive point-level control and contain no mercury. They allow you to be environmentally safe without sacrificing accuracy.

MGS-314: SPDT 5A service

MGS-314D: DPDT 10A service

MGS-314L: SPDT 1A service used with standard MULTIVIEW?

MGS-314M: SPDT 1A service used with either TMMG (Top Mount Magnetic Gage) or MMG (Mini Magnetic Gage)

Transmitters can be added for continuous level control.

MGT Transmitters provide continuous level indication to remote locations via 4 to 20 mA loop-powered operation.

MGT-362: A reed switch based unit available in integral and remote mounting styles

MGT-362B or C: An in-tank reed switch based unit. The MGT-362B is an NPT-mounted assembly. The MGT-362C is a flange-mounted assembly. Both are available in integral or remote mounting styles.

MGT-367: A magnetostrictive transmitter available with or without Hart protocol.

Please visit our web site and fill our our Penberthy form for more information.