Showing posts with label Temperature Controllers. Show all posts
Showing posts with label Temperature Controllers. Show all posts

Monday, April 29, 2019

Watlow Heaters Heating Requirements

General Method for Determining Watlow Heater Requirements


Electric Heaters, Heating Elements and Controls
Contact Flow Factor HERE!


Most electrical heating problems can be readily solved by determining the heat required to do the job. To do this, the heat requirement must be converted to electrical Power and the most practical heater can then be selected for the job. Whether the problem is heating solids, liquids or gases, the method, or approach, to determining the Power requirement is the same.
All heating problems involve the following steps to their solution:

Step 1: Define the Heating Problem

  • Gather application information
  • Sketch problem for visual reference

Step 2: Calculate Power Requirements

  • System start-up power requirement
  • System maintenance power requirements
  • Operating heat losses

Step 3: Review System Application Factors

  • Operating temperature
  • Operating efficiency
  • Safe/permissible watt densities
  • Mechanical considerations
  • Operating environment factors
  • Heater life requirements
  • Electrical lead considerations

Step 4: Select Heater

  • Type
  • Size
  • Quantity

Step 5: Select Control System

  • Type of temperature sensor and location
  • Type of temperature controller
  • Type of power controller

Defining the Problem

Your heating problem must be clearly stated, paying careful attention to defining operating parameters. Take these into consideration:

  • Minimum start and finish temperatures expected
  • Maximum flow rate of material(s) being heated
  • Required time for start-up heating and process cycle times
  • Weights and dimensions of both heated material(s) and containing vessel(s)
  • Effects of insulation and its thermal properties
  • Electrical requirements — voltage
  • Temperature sensing methods and location(s)
  • Temperature controller type
  • Power controller type
  • Electrical limitations
  • And since the thermal system you're creating may not take into account all the possible or unforeseen heating requirements, don't forget a safety factor. A safety factor increases heater capacity beyond calculated requirements.

Calculations for Required Heat Energy

When performing your own calculations, refer to Equations for values of materials covered by these equations.
The total heat energy (kWh or Btu) required to satisfy the system needs will be either of the two values shown below depending on which calculated result is larger.
  • Heat required for start-up
  • Heat required to maintain the desired temperature
The power required (kW) will be the heat energy value (kWh) divided by the required start-up or working cycle time. 
The kW rating of the heater will be the greater of these values plus a safety factor.
The calculation of start-up and operating requirements consist of several distinct parts that are best handled separately. However, a short method can also be used for a quick estimate of heat energy required.

Safety Factor Calculation

You should always include a safety factor of varying size to allow for unknown or unexpected conditions. The size of the safety factor is dependent on the accuracy of the wattage calculation. Heaters should always be sized for a higher value than the calculated figure. A factor of 10% is adequate for small systems that are closely calculated; 20% additional wattage is more common. Safety factors of 20% and 35% are not uncommon, and should be considered for large systems, such as those containing doors that open or are large radiant heat applications. You'll also want to predict how long your system will operate without failure, so examine the amount of heater life you'll be needing. And because electricity costs money, take efficiency factors into account so your system will cost as little as possible to operate.
With these considerations in mind, carefully review them all to be sure you do, in fact, have definitive information to decide on a particular solution to your heating problem. Some of this supporting information may not be readily available or apparent to you. You may find it necessary to consult the reference tables and charts in this reference data section, or reference a book that deals with the particular parameter you need to define. At the minimum, the thermal properties of both the material(s) being processed/heated and their containing vessel(s) will be required.
Figuring a safety factor requires some intuition on your part. The list of possible influences can be great. From changing ambient operating temperatures, caused by seasonal changes, to a change in material or material temperature being processed, you must carefully examine all the influences.
Generally speaking, the smaller the system with fewer variables and outside influences---the smaller the safety factor. Conversely, the larger the system and the greater the variables and outside influences — the greater the safety factor.
Here are some general guidelines:
  • 10% safety factor for small systems with closely calculated power requirements
  • 20% safety factor is average20% to 35% for large systems
The safety factor should be higher for systems that have production operations that contain equipment cycles subjecting them to excessive heat dissipations, e.g.: opening doors on furnaces, introducing new batches of material that can be of varying temperatures, large radiant applications and the like.
Flow Factor
216-765-4231

Wednesday, January 31, 2018

Fenwal Brass Switches Discontinued

Flow Factor announces that the brass Fenwal Thermoswitches are discontinued by Fenwal.
The brass switches have stainless steel versions and these are still available.  We are leaving the brass switches on the website but will ship the stainless versions if the brass are mistakingly ordered.  The Stainless Steel switches have a higher temperature rating of 600F whereas the brass were rated to 400F.  Both have a lower limit of -100F. All dimensions and features are the same.

Click HERE to go to the Fenwal Thermoswitch page on Flow Factor.

Brass Switches
17000-0
17021-0
17100-0
17121-0
17200-0
17221-0
17300-0
17321-0
17800-0
17821-0
18000-0
18021-0

Stainless Switches
17002-0
17023-0
17102-0
17123-0
17202-0
17223-0
17302-0
17323-0
17802-0
17823-0
18002-0
18023-0

Flow Factor has a small supply of the brass switches but when they are gone we cannot get any more.

Contact Flow Factor

216-765-4231

Monday, May 30, 2016

Barksdale Explosion Proof Temperature Switch L1X Series

Flow Factor sells the Barksdale L1X series Explosion Proof Temperature Switch

Explosion Proof - from 50° to 600°F












Applications

  • Oil & gas
  • Heat tracing
  • Printing machinery
  • Compressors
  • Process equipment
  • Machine tools and industrial equipment
ATEX (optional):

EX models are ATEX marked as follows:
0344, ISSeP 08 ATEX029X
II 2G D, Ex d IIC T6 Gb
Ex tb IIIC T80°C Db IP66
-40°C ≤ Tamb ≤ +75°C


Switch:
Single Setting: One (1) single pole double throw (SPDT) circuit.

Wetted Parts: 304 stainless steel

Enclosure/Housing: 
Class I, Division 1 & 2
NEMA 4, 7, & 9
Tamper-proof external adjustment,
enclosed terminal strip.

Immersion length 2-1/16 inches

Barksdale Explosion-Proof Temperature Switch, L1XH201S, Stainless Steel Sensor, -50° to 75° Range

Barksdale Explosion-Proof Temperature Switch, L1XH203S, Stainless Steel Sensor, 75° to 200° Range

Barksdale Explosion-Proof Temperature Switch, L1XH351S, Stainless Steel Sensor, 100° to 225° Range

Barksdale Explosion-Proof Temperature Switch, L1XH204S, Stainless Steel Sensor, -50° to 200° Range

Barksdale Explosion-Proof Temperature Switch, L1XH454S, Stainless Steel Sensor, 150° to 450° Range

Go HERE of all the Barksdale L1X switches from Flow Factor.


866-360-9830

Monday, August 31, 2015

Autonics Temperature Controllers Type TC4 - 72x72 mm

Flow Factor sells Autonics Temperature Controllers

Autonics TC4 controllers are inexpensive digital temperature controllers. Below are 24 volt controllers in the 72x72 mm panel cutout size.  Unit can usually be shipped with 24 hours of an order.

For a complete list of our 24 volt controllers, click HERE.


Autonics TC4S-N2R Digital Temperature Control, 1/16 DIN, PID or On/Off Control, 3 amp Relay Output or12vdc SOLID STATE DRIVER Output, Type J, K or L Thermocouple Sensor input or 100 Ohm RTD Sensor Input, 24v AC/DC. 4 Digit Digital Display

Autonics TC4S-12R Digital Temperature Control, 1/16 DIN, PID or On/Off Control, 3 amp Relay Output or12vdc SOLID STATE DRIVER Output, 1 Alarm Output, Type J, K or L Thermocouple Sensor input or 100 Ohm RTD Sensor Input, 24v AC/DC. 4 Digit Digital Display

Autonics TC4S-22R Digital Temperature Control, 1/16 DIN, PID or On/Off Control, 3 amp Relay Output or12vdc SOLID STATE DRIVER Output, 2 Alarm Outputs Type J, K or L Thermocouple Sensor input or 100 Ohm RTD Sensor Input, 24v AC/DC. 4 Digit Digital Display

Autonics TC4M-N2R Digital Temperature Control, 72x72 mm, PID or On/Off Control, 3 amp Relay Output or12vdc SOLID STATE DRIVER Output, Type J, K or L Thermocouple Sensor input or 100 Ohm RTD Sensor Input, 24v AC/DC. 4 Digit Digital Display

Autonics TC4M-12R Digital Temperature Control, 72x72 mm, PID or On/Off Control, 3 amp Relay Output or12vdc SOLID STATE DRIVER Output, 1 Alarm Output, Type J, K or L Thermocouple Sensor input or 100 Ohm RTD Sensor Input, 24v AC/DC. 4 Digit Digital Display

Autonics TC4M-22R Digital Temperature Control, 72x72 mm, PID or On/Off Control, 3 amp Relay Output or12vdc SOLID STATE DRIVER Output, 2 Alarm Outputs Type J, K or L Thermocouple Sensor input or 100 Ohm RTD Sensor Input, 24v AC/DC. 4 Digit Digital Display


Contact Flow Factor HERE.



















Saturday, February 21, 2015

Carlo Gavazzi Temperature Meters

Temperature Meters from Carlo Gavazzi and Flow Factor

Carlo Gavazzi offers a comprehensive range of digital panel meters, HMIs and digital displays (current meters, ammeters, voltmeters, frequency meters, temperature meters and temperature controllers, tachometers, and rate meters) for the OEM, Panel Builder, Instrumentation, and MRO customer. Covering most input types (current/voltage/temperature/resistance/RPM), Gavazzi digital panel meters are well suited for your display requirements.

The Carlo Gavazzi UDM40 series is a hi-tech modular panel meter developed to meet advanced application needs. The Gavazzi UDM40 series Features a 4 digit display.  The meter front is rated at IP67, NEMA12, NEMA 4X for indoor use only. Input Power outages are 90-260 AC/DC, 18-60 AC/DC and 10-28v DC. 

The Gavazzi UDM40 series accepts most signal inputs (current, voltage, temperature, tach) and offers an analogue output as well as up to 4 digital outputs (relay). Since these are modular meters, outputs can be added at any time in the field. Remote monitoring via a PLC or PC is possible by inserting an RS485 communication module into the meter. In this way many meters can be monitored without adding a lot of expensive analogue cards to your PLC.

The Carlo Gavazzi UDM40 meter also features a 3-color display allowing at a glance indication of relative operating condition (OK - Green, Caution - Yellow, or Alarm - Red). Furthermore, the UDM40 is also able to handle and correctly display non-linear signals. Temperature inputs are Thermocouple types J,K,S,T and E and RTD resistance detectors.  Relay outputs are up to 8 amps up to 240 volts single phase. The analog outputs are 0-20mA or 0-10v DC.


The UDM40 Agency approvals are CE, cCSA, UL, e cRU.



Carlo Gavazzi UDM40TRXXXR2HXX 4 DIGIT Digital Meter, 1/8 DIN, Two 8 amp Relay outputs for control, Inputs are T/C and RTD, Input Voltage 90-240 VAC. IP67 NEMA 4x front face

Carlo Gavazzi UDM40TRXXXR2LXX 4 DIGIT Digital Display Meter, 1/8 DIN, Two 8 amp Relay outputs for control, Inputs are T/C and RTD, Input Voltage 18-60v AC/DC. IP67 NEMA 4x front face

Carlo Gavazzi UDM40TRXXXR5HXX 4 DIGIT Digital Display Meter, 1/8 DIN, FOUR 5 amp Relay outputs for control, Inputs are T/C and RTD, Input Voltage 90-240 VAC. IP67 NEMA 4x front face

Carlo Gavazzi UDM40TRXXXR5LXX 4 DIGIT Digital Display Meter, 1/8 DIN, FOUR 5 amp Relay outputs for control, Inputs are T/C and RTD, Input Voltage 18-60v AC/DC. IP67 NEMA 4x front face

Carlo Gavazzi UDM40TRXSXR2HXX 4 DIGIT Display Meter with RS 485 communications, 1/8 DIN size, Two 8 amp Relay outputs for control, Inputs are T/C and RTD, Input Voltage 90-240 VAC. IP67 NEMA 4x front face

Carlo Gavazzi UDM40TRXSXR2LXX 4 DIGIT Digital Display Meter with RS 485 communications, 1/8 DIN size, Two 8 amp Relay outputs for control, Inputs are T/C and RTD, Input Voltage 18-60v AC/DC. IP67 NEMA 4x front face

Carlo Gavazzi UDM40TRXAVR2HXX 4 DIGIT Display Meter, 1/8 DIN, Two 8 amp Relay outputs and One Analog (0-20mA or 0-10vdc) for control, Inputs are T/C and RTD, Input Voltage 90-240 VAC. IP67 NEMA 4x front face

Carlo Gavazzi UDM40TRXAVR2LXX 4 DIGIT Digital Display Meter, 1/8 DIN, Two 8 amp Relay outputs and One Analog (0-20mA or 0-10vdc) for control, Inputs are T/C and RTD, Input Voltage 18-60v AC/DC. IP67 NEMA 4x front face

Carlo Gavazzi UDM40TRXAVR4HXX 4 DIGIT Digital Meter, 1/8 DIN, Two 8 amp Relay outputs and One Analog (0-20mA or 0-10vdc) for control, Inputs are RTD and T/C, Input Voltage 90-240 VAC. IP67 NEMA 4x front face

Carlo Gavazzi UDM40TRXAVR4LXX 4 DIGIT Digital Display Meter, 1/8 DIN, Two 8 amp Relay outputs and One Analog (0-20mA or 0-10vdc) for control, T/C and RTD inputs, Input Voltage 18-60v AC/DC. IP67 NEMA 4x front face

Carlo Gavazzi UDM40TRXXXR23XX 4 DIGIT Digital Display Meter, 1/8 DIN, Two 8 amp Relay outputs for control, Inputs are T/C and RTD, Input Voltage 10-28 VDC. IP67 NEMA 4x front face

Carlo Gavazzi UDM40TRXAVR43XX 4 DIGIT Digital Display Meter, 1/8 DIN, Two 8 amp Relay outputs and One Analog (0-20mA or 0-10vdc) for control, Inputs are T/C and RTD, Input Voltage 10-28 VDC. IP67 NEMA 4x face

For more information please CONTACT Flow Factor.


Wednesday, February 18, 2015

Chromalox Series 4040, 6040, 8040 Temperature Controllers

Chromalox Series 40 Temperature Controllers from Flow Factor

Whether you have to manage temperature, flow, valve positioning or pressure, the Chromalox 40 Series Temperature and Process Controllers provide you with a comprehensive feature list and the flexibility to meet your most demanding process and temperature needs. Application needs change over time, but that doesn't mean that you'll need to change your controller. The Chromalox 40 series modular card design provides the owner with the flexibility to alter the functionality with ease. Expansion from 1 to 3 outputs, as well as communications and remote setpoint is easily accomplished and automatically recognized by the firmware. The optional ChromaWareTM configuration software allows the owner to program multiple units efficiently and store parameter settings for later use.

For Controllers with 120/240 AC volt input control voltage Click Here.

For Controllers with 24 Volt AC/DC, 24vac or 24vdc control voltage click Here.

4040
1/4 DIN Temperature and Process Controller
  • Universal Input
  • Ramping Setpoint
  • Adjustable Hysteresis
  • Valve Motor Drive Position
  • Heater Break Alarm Function
  • Remote/Dual Setpoint Options
  • Security Options
  • Available in 1/4 DIN
  • Optional Configuration Software
  • UL, cUL, CE & CSA
  • 3 Year Warranty
  • Jumperless Configuration
  • Auto Detected Hardware
  • Process & Loop Alarms
  • ModBus Communications
  • Auto or Manual Tuning
  • Heat/Cool Operation
  • Up to 3 Outputs
  • Optional 24 Vdc Transmitter Power Supply

Chromalox Instruments and Controls 4040-ARR000 (314528) Digital Process Temperature Control, 1/4 DIN Size (96x96), PID Control and Heater Break Alarm, 4 digit digital displays (Process and Set Point), Analog and Relay outputs for Process control and temperature control, Universal Sensor or voltage input (T/C, 0-20mA, 0-10vdc, RTD), Input Voltage 100-240 VAC

Chromalox Instruments and Controls 4040-R00000 (314704) Digital Process Temperature Control, 1/4 DIN (96x96), On/Off and PID Control and Heater Break Alarm, 4 digit digital displays (Process and Set Point), 1 Relay output for control, Universal Sensor and process input (T/C, 0-20mA, 0-10vdc, RTD), Control Input Voltage 100-240 VAC

Chromalox Instruments and Controls 4040-RRR000 (314510) Digital Temperature Control, 1/4 DIN (96x96), PID Control and Heater Break Alarm, 4 digit digital displays (Process and Set Point), 3 Relay outputs for control, Universal input (T/C, 0-20mA, 0-10vdc, RTD), Input Voltage 100-240 VAC

8040
1/8 DIN Temperature and Process Controller
  • Universal Input
  • Ramping Setpoint
  • Adjustable Hysteresis
  • Valve Motor Drive Position
  • Heater Break Alarm Function
  • Remote/Dual Setpoint Options
  • Security Options
  • Available in 1/8 DIN
  • Optional Configuration Software
  • UL, cUL, CE & CSA
  • 3 Year Warranty
  • Jumperless Configuration
  • Third-party certifications: CSA, CE, cRUus
  • Auto Detected Hardware
  • Process & Loop Alarms
  • ModBus Communications
  • Auto or Manual Tuning
  • Heat/Cool Operation
  • Up to 3 Outputs
  • Optional 24 Vdc Transmitter Power Supply
Chromalox Controls 8040-R00000 (314544) Process Digital Temperature Control, 1/8 DIN (96x48), PID Control and On/Off Control and Heater Break Alarm, 4 digit displays (Process Variable and Set Point), 1 Relay output for control, Universal input (T/C, 0-20mA, 0-10vdc, RTD), Input Control Voltage 100-240/1/60 Volts AC

6040
1/16 DIN Temperature and Process Controller
  • Optional Configuration Software
  • Ramping Setpoint
  • Adjustable Hysteresis
  • Valve Motor Drive Position
  • Heater Break Alarm Function
  • Remote/Dual Setpoint Options
  • Security Options
  • Available in 1/16 DIN
  • UL, cUL, CE & CSA
  • 3 Year Warranty
  • Jumperless Configuration
  • Auto Detected Hardware
  • Process & Loop Alarms
  • ModBus Communications
  • Auto or Manual Tuning
  • Heat/Cool Operation
  • Up to 3 Outputs
  • Optional 24 Vdc Transmitter Power Supply

Chromalox Process Controls 6040-RRR000 (314640) Digital Process Temperature Control, 1/16 DIN (48x48), On/Off and PID Control and Heater Break Alarm, 4 digit displays (Process and Set Point), 3 Relay outputs (2 amps) for control, Universal Sensor input (T/C, 0-20mA, 0-10vdc, RTD), Input Control Voltage 100-240 VAC

Chromalox Instruments 6040-S00000 (314720) Process Temp Control, 1/16 DIN (48x48), PID Control and Heater Break Alarm, 2 digital displays (Process and Set Point), 1 Solid State Relay output (0/10 volts dc) for control, Universal Sensor and voltage input (T/C, 0-20mA, 0-10vdc, RTD), AC Input Voltage 100-240/1/60

Chromalox Instruments and Controls 6040-SR0000 (314632) Temperature Controller, 1/16 DIN (48x48), PID Control and Heater Break Alarm, 4 digit digital displays (Process Variable and Set Point in degrees F or C), 1 RELAY Output and 1 SSR Output for control, Voltage and Sensor input (T/C, 0-20mA, 0-10vdc, RTD), Control Input Voltage 100-240 VAC

Chromalox Instruments and Controls 6040-SR0001 Digital Temperature Control, 1/16 DIN (48x48), On/Off and PID Control and Heater Break Alarm, digital displays (2) (Process and Set Point), 1 RELAY Output and 1 Solid State Relay Output Driver for control, Universal input (T/C, 0-20mA, 0-10vdc, RTD), Input Voltage 24-48v AC/DC

Chromalox 6040 PCNs also available  314624   314616   314659

For Questions or Quotes 866-360-9830 or email to info@flowfactor.com

Flow Factor Contact Us Page









Tuesday, October 2, 2012

Temperature Controllers by Autonics

Flow Factor can supply Autonics Temperature Controllers

Autonics TCN Series is economical temperature controllers having dual preset indicator display to increase user convenience. The series realizes ideal temperature controlling with newly developed PID control algorithm and 100ms high speed sampling; in addition, the series allows users to take advantage of economical controlling with SSRP and relay outputs. Now meet Autonics TCN Series to take advantages of economical TC Series with upgraded convenience with dual display.  TCN Series is economical temperature controllers having dual preset indicator display to increase user convenience. The series realizes ideal temperature controlling with newly developed PID control algorithm and 100ms high speed sampling; in addition, the series allows users to take advantage of economical controlling with SSRP and relay outputs.




* Dual preset indicator display SV & PV simultaneously

* 8 types of input sensors

RTD : Pt100Ω, Cu50Ω

TC : K(CA), J(IC), L(IC), T(CC), R(PR), S(PR)

* Realizes ideal temp. controlling with newly developed PID control algorithm and 100ms high speed sampling

* Relay output and SSRP output embodied together and 2EA alarm outputs supported

: SSRP output makes phase control and cycle control possible. (AC power)


* Dramatically increased visibility using wide display part

* Mounting space saving with compact design

: Approx. 38% reduced size compared with existing models (depth-based)


4 Sizes available:  96x96mm (1/4 din) ; 72x72mm ; 96x48mm (1/8 din) ; 48x48mm ( 1/16 din )

Autonics TCN4S-24R Economical Temperature Control, 1/16 DIN, PID Control, 4 digit digital display, Selectable Relay Output or SSR output, Universal input, 100-240 VAC


Autonics TCN4L-24R Economical Temperature Control, 1/4 DIN, PID Control, 4 digit digital display, Selectable Relay Output or SSR output, Universal input, 100-240 VAC

Autonics TC4H-12R Digital Temperature Control, 1/8 DIN, PID or On/Off Control, 3 amp Relay Output or12vdc SOLID STATE DRIVER Output, 1 Alarm Output, Type J, K or L Thermocouple Sensor input or 100 Ohm RTD Sensor Input, 24v AC/DC. 4 Digit Digital Display


Autonics TZN/TZ Temperature Controllers

The Autonics Dual PID temperature controller TZN/TZ realizes ±0.3% high display accuracy by F.S value of each input. The series also supports various functions including 2-step auto tuning control function, diverse sub-output function; in addition, 13 kinds of multi-input function which makes temperature sensors, voltage and current input possible is also embodied in order to guarantee better users’ convenience.




*Dual PID auto tuning function :
 High-speed response of PID control to reach to the desired
 value fast, low-speed of response of PID control to minimize
 the overshoot even though response is a little bit slow.
*High display accuracy :
 ±0.3%(by F.S value of each input)
*2-Steps auto tuning control function
*Multi-input function(13 kinds of multi-input selection function) :
 Temperature sensor, voltage and current selection function.
*Various sub output function :
 Includes in LBA, SBA, 7kinds of alarm output and 4 kinds
 of alarm option function, PV value transmission output(4-20mADC),
 RS485 communication output
*Display the decimal point for analog input


Autonics TC series Temperature Controllers

Autonics TC Series - one of the most cost effective temperature controlling solution with essential functions and improved performance - realizes ideal temperature controlling with newly developed PID control algorithm and 100ms high speed sampling. Especially, that both SSRP output and relay output are supported to realize effective and economical controlling; in addition, improved visibility and compact size is another feature of TC Series.





Major features
* Realizing 100ms high speed sampling

* SSRP output and relay output embodied together
: SSRP output makes phase control and cycle control possible

* Dramatically increased visibility using wide display and high luminance LED

* Mounting space saving with compact design
: downsized by approx. 38%(60mm) in depth compared to existing models

* Deviation between SV and PV indicatable
* Fives sizes available:  96x96mm ; 96x48mm ; 72x72mm, 72x36mm, 48x48mm
Application Fields
Applicable to various temperature controlling required facilities such as injection molding machinery

Contact Flow Factor